34 resultados para red to far-red ratio


Relevância:

60.00% 60.00%

Publicador:

Resumo:

A compact picosecond all-room-temperature orange-to-red tunable laser source in the spectral region between 600 and 627 nm is demonstrated. The tunable radiation is obtained by second-harmonic generation in a periodically poled potassium titanyl phosphate (PPKTP) multimode waveguide using a tunable quantum-dot external-cavity mode-locked laser. The maximum second-harmonic output peak power of 3.91 mW at 613 nm is achieved for 85.94 mW of launched pump peak power at 1226 nm, resulting in conversion efficiency of 4.55%. © 2013 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An anastomosis is a surgical procedure that consists of the connection of two parts of an organ and is commonly required in cases of colorectal cancer. About 80% of the patients diagnosed with this problem require surgery. The malignant tissue located on the gastrointestinal track must be resected and the most common procedure adopted is the anastomosis. Therefore, an anastomotic leak represents a significant problem and increases the duration of hospital stay, which is associated with remedial treatment and recovery, causing, as a result, a negative financial impact. A number of techniques to treat, prevent and even detect an anastomotic leakage are under investigation. However, studies show that these techniques are not always able to prevent an anastomotic leak from occurring. This paper discusses the monitoring of leakage through differently sized and differently positioned leak holes in phantom colons, using physical experiments and a Computational Fluid Dynamics package called FloWorks. © 2011 Taylor & Francis Group.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Red blood cells (RBCs) are key players in systemic oxygen transport. RBCs respond to in vitro hypoxia  through  the so-called  oxygen-dependent  metabolic  regulation,  which  involves  the competitive  binding  of  deoxyhemoglobin  and  glycolytic  enzymes  to  the  N-terminal  cytosolic domain  of  band  3.  This  mechanism  promotes  the  accumulation  of  2,3-DPG,  stabilizing  the deoxygenated state of hemoglobin, and cytosol acidification, triggering oxygen off-loading through the  Bohr  effect.  Despite  in  vitro  studies,  in  vivo adaptations  to  hypoxia  have  not  yet  been completely elucidated. Within  the  framework  of  the AltitudeOmics  study,  erythrocytes  were  collected  from  21 healthy volunteers at sea level, after exposure to high altitude (5260m) for 1, 7 and 16days, and following  reascent  after  7days  at 1525m.  UHPLC-MS  metabolomics  results  were  correlated  to physiological and athletic performance parameters. Immediate  metabolic  adaptations  were  noted as early as a few hours from ascending  to >5000m, and maintained for 16 days at high altitude.  Consistent with the mechanisms elucidated in vitro, hypoxia promoted glycolysis and deregulated the pentose phosphate pathway, as well purine catabolism, glutathione homeostasis, arginine/nitric oxide and sulphur/H2S metabolism. Metabolic adaptations were preserved one week after descent, consistently with improved physical performances in comparison to the first ascendance, suggesting a mechanism of metabolic memory.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

An anastomosis is a surgical procedure that consists of the re-connection of two parts of an organ and is commonly required in cases of colorectal cancer. Approximately 80% of the patients diagnosed with this problem require surgery. The malignant tissue located on the gastrointestinal track must be resected and the most common procedure adopted is the anastomosis. Studies made with 2,980 patients that had this procedure, show that the leakage through the anastomosis was 5.1%. This paper discusses the dynamic behavior of N2O gas through different sized leakages as detected by an Infra-Red gas sensor and how the sensors response time changes depending on the leakage size. Different sized holes were made in the rigid tube to simulate an anastomostic leakage. N2O gas was injected into the tube through a pipe and the leakage rate measured by the infra-red gas sensor. Tests were also made experimentally also using a CFD (Computational Fluid Dynamics) package called FloWorks. The results will be compared and discussed in this paper.