49 resultados para corneal biometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment of presbyopia has been the focus of much scientific and clinical research over recent years, not least due to an increasingly aging population but also the desire for spectacle independence. Many lens and nonlens-based approaches have been investigated, and with advances in biomaterials and improved surgical methods, removable corneal inlays have been developed. One such development is the KAMRA™ inlay where a small entrance pupil is exploited to create a pinhole-type effect that increases the depth of focus and enables improvement in near visual acuity. Short- and long-term clinical studies have all reported significant improvement in near and intermediate vision compared to preoperative measures following monocular implantation (nondominant eye), with a large proportion of patients achieving Jaeger (J) 2 to J1 (~0.00 logMAR to ~0.10 logMAR) at the final follow-up. Although distance acuity is reduced slightly in the treated eye, binocular visual acuity and function remain very good (mean 0.10 logMAR or better). The safety of the inlay is well established and easily removable, and although some patients have developed corneal changes, these are clinically insignificant and the incidence appears to reduce markedly with advancements in KAMRA design, implantation technique, and femtosecond laser technology. This review aims to summarize the currently published peer-reviewed studies on the safety and efficacy of the KAMRA inlay and discusses the surgical and clinical outcomes with respect to the patient’s visual function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interaction of the wound dressing as a biomaterial with the wound bed is the central issue of this chapter. The interfacial phenomenon that encompasses the biological and biochemical consequences that arise when a biomaterial is introduced to a host biological environment is discussed. A great deal can be learned from observations arising from the behaviour of biomaterials at other body sites; one particularly relevant body site in the context of wound healing is the anterior eye. The cornea, tear film and posterior surface of the contact lens provide an informative model of the parallel interface that exists between the chronic wound bed, wound fluid and the dressing biomaterial. © 2011 Woodhead Publishing Limited All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in C3, C4, C4, root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is an Olympic year and we have just witnessed the fantastic games hosted by Rio de Janeiro. Well done to team USA for winning the most medals overall but also well done to so many other nations and individuals who performed so well or were ambassadors in other ways. Teenage swimmer Yusra Mardini who swam for the refugee team and South Africa's Wayde van Niekerk who broke the longstanding 400 m record of Michael Johnson that has stood since 1999. Of course, we must mention sprinter Usain Bolt and swimmer Michael Phelps, who have now transcended superstar status and entered a new level of icon. My personal highlight was the sportsmanship witnessed in the 5000 m when American Abbey D’Agostino was accidentally felled by New Zealand runner Nikki Hamblin. D’Agostino helped Hamblin back to her feet but slumped to the track after realising her own injury. Hamblin helped her up and stayed with her so that both completed the race. The International Olympic Committee has awarded both with the prestigious Pierre de Coubertin award, also known as the International Fair Play Trophy. Fair play is of paramount importance in publishing in peer-reviewed papers. At CLAE we try and maintain, as do other journals, this by ensuring double blind peer review and allowing authors to select the most appropriate handling editor for their submission. Our handling editors are placed across the world (2 in Europe, 1 in the Americas, 1 in Australia and 1 in Asia) and part of their role is to encourage submissions from their region. Over the last decade we certainly have seen more and more papers from places that haven’t previously published in CLAE. In this issue of CLAE we have a true international blend of papers. We have papers from authors from the UK, USA, Iran, Jordan, France, Poland, Turkey, Nigeria, France, Spain and Brazil. I think it's a testament to the continued success of the journal that we are attracting new writers from so many parts of the world and retain papers from more established authors and research centres. We do continue to attract many weaker papers that are rejected early in the review process. Often these will be unexceptional case reports or papers describing a surgical technique. Case reports are published but only those that offer something original and especially those with interesting photographs. In this issue you will see Professor James Wolffsohn (UK) has an interesting paper around a lot of the focus of his recent research activity into clinical evaluation of methods of correcting presbyopia. In this paper he highlights predictors to aid success of presbyopic contact lenses. If you have been involved in any clinical work or research in the field of dry eye disease then you will know well the CLDEQ (Contact Lens Dry Eye Questionnaire) devised by Robin Chalmers and her colleagues (USA). This issue of CLAE details the latest research using the CLDEQ-8 (the 8 item version of the CLDEQ). The Shahroud Eye Cohort Study has produced many papers already and in this issue we see Fotouhi Akbar (Iran) looking at changes in central and peripheral corneal thickness over a five year period. These days we use a lot of new instrumentation, such as optical low-coherence reflectometry. In this issue Emre Güler (Turkey) compares that to a new optical biometry unit. Dry eye is more common and in this issue we see a study by Oluyemi Fasina (Nigeria) to investigate the disease in adults in South-West Nigeria. The TearLab™ is now commonly used to investigate osmolarity and Dorota Szczesna-Iskander (Poland) looks at measurement variability of this device. Following the theme of dry eyes and tear testing Renaud Laballe (France) looks at the use of scleral lenses as a reservoir-based ocular therapeutic system. In this issue we have a couple of papers looking at different aspects of keratoconus. Magdalena Popiela (UK) looks at demographics of older keratoconic patients in Wales, Faik Orucoglu (Turkey) reports a novel scoring system for distinguishing keratoconus from normal eyes, Gonzalo Carracedo (Spain) reports the effect of rigid gas permeable lens wear on dry eye in keratoconus and Hatice Nur Colak (Turkey) compares topographic and aberrations in keratoconus. Other interesting papers you will find are Mera Haddad (Jordan) investigates contact lens prescribing in Jordan, Camilla Fraga Amaral (Brazil) offers a report on the use of ocular prosthetics, Naveed Ahmed Khan (Malaysia) reports of the use of dimethyl sulfoxide in contact lens disinfectant and Michael Killpartrick (UK) offers a short piece with some useful advice on contamination risk factors that may occur from the posterior surface of disposable lenses. So for this issue I would say that the Gold Medal for biggest contribution in terms of papers has to go to Turkey. I could have awarded it to the UK too, but Turkey has three full papers and the UK has two plus one short communication. Turkey is also one of the countries that has shown the largest increase in submissions over the last decade. Finally, welcome aboard to our newest Editorial Board Member Nicole Carnt from Australia. Nicole has been an active researcher for many years and acted as a reviewer for CLAE many times in the past. We look forward to working with you.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the relationship between short-term and long-term changes in power at different corneal locations relative to the change in central corneal power and the 2-year change in axial elongation relative to baseline in children fitted with orthokeratology contact lenses (OK). METHODS: Thirty-one white European subjects 6 to 12 years of age and with myopia −0.75 to −4.00 DS and astigmatism ≤1.00 DC were fitted with OK. Differences in refractive power 3 and 24 months post-OK in comparison with baseline and relative to the change in central corneal power were determined from corneal topography data in eight different corneal regions (i.e., N[nasal]1, N2, T[temporal]1, T2, I[inferior]1, I2, S[superior]1, S2), and correlated with OK-induced axial length changes at two years relative to baseline. RESULTS: After 2 years of OK lens wear, axial length increased by 0.48±0.18 mm (P0.05). CONCLUSION: The reduction in central corneal power and relative increase in paracentral and pericentral power induced by OK over 2 years were not significantly correlated with concurrent changes in axial length of white European children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To convert objective image analysis of anterior ocular surfaces into recognisable clinical grades, in order to provide a more sensitive and reliable equivalent to current subjective grading methods; a prospective, randomized study correlating clinical grading with digital image assessment. Methods. The possible range of clinical presentations Of bulbar and palpebral hyperaemia, palpebral roughness and corneal staining were represented by 4 sets of 10 images. The images were displayed in random order and graded by 50 clinicians using both subjective CCLRU and Efron grading scales. Previously validated objective image analysis was performed 3 times oil each of the 40 images. Digital measures included edge-detection and relative-coloration components. Step-wise regression analysis determined correlations between the average subjective grade and the objective image analysis measures. Results. Average subjective grades Could be predicted by a combination of the objective image analysis components. These digital ``grades'' accounted for between 69%, (for Efron scale-graded palpebral redness) and 98% (for Efron scale-graded bulbar hyperaemia) of the subjective variance. Conclusions. The results indicate that clinicians may use a combination of vessel areas and overall hue in their judgment of clinical severity for certain conditions. Objective grading call take these aspects into account, and be used to predict an average ``objective grade'' to be used by a clinician in describing the anterior eye. These measures are more sensitive and reliable than subjective grading while still utilizing familiar terminology, and can be applied in research or practice to improve the detection, and monitoring of ocular surface changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A number of neurodegenerative diseases caused by prions have been described recently. These include Creutzfeldt-Jakob disease (CJD) in humans, scrapie in sheep and BSE in cows. Patients with CJD may suffer a range of visual problems including eye movement deficits and visual hallucinations. In addition, it is possible that CJD may be acquired via corneal transplant and that prions may be transmitted by reusable contact lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. A clinical evaluation of the Shin-Nippon NVision-K 5001 (also branded as the Grand Seiko WR-5100K) autorefractor (Japan) was performed to examine validity and repeatability compared with subjective refraction and Javal-Schiotz keratometry. Methods. Measurements of refractive error were performed on 198 eyes of 99 subjects (aged 23.2 ± 7.4 years) subjectively (noncycloplegic) by one masked optometrist and objectively with the NVision-K autorefractor by a second optometrist. Keratometry measurements using the NVision-K were compared with the Javal-Schiotz keratometer. Intrasession repeatability of the NVision-K was also assessed on all 99 subjects together with intersession repeatability on a separate occasion separated by 7 to 14 days. Results. Refractive error as measured by the NVision-K was found to be similar (p = 0.67) to subjective refraction (difference, 0.14 ± 0.35 D). It was both accurate and repeatable over a wide prescription range (-8.25 to +7.25 D). Keratometry as measured by the NVision-K was found to be similar (p > 0.50) to the Javal-Schiotz technique in both the horizontal and vertical meridians (horizontal: difference, 0.02 ± 0.09 mm; vertical: difference, 0.01 ± 0.14 mm). There was minimal bias, and the results were repeatable (horizontal: intersession difference, 0.00 ± 0.09 mm; vertical: intersession difference, -0.01 ± 0.12 mm). Conclusion. The open-view arrangement of the Shin-Nippon NVision-K 5001 facilitates the measurement of static refractive error and the accommodative response to real-world stimuli. Coupled with its accuracy, repeatability, and capability to measure corneal curvature, it is a valuable addition to objective instrumentation currently available to the optometrist and researcher.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cataract surgery is a technique described since recorded history, yet it has greatly evolved only in the latter half of the past century. The development of the intraocular lens and phacoemulsification as a technique for cataract removal could be considered as the two most significant strides that have been made in this surgical field. This review takes a comprehensive look at all aspects of cataract surgery, starting from patient selection through the process of consent, anaesthesia, biometry, lens power calculation, refractive targeting, phacoemulsification, choice of intraocular lens and management of complications, such as posterior capsular opacification, as well as future developments. As the most common ophthalmic surgery and with the expanding range of intraocular lens options, optometrists have an important and growing role in managing patients with cataract.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To determine the critical fitting characteristics of modern soft contact lens fits and from this to devise a simplified recording scheme. Methods: Ten subjects (aged 28.1 ± 7.4 years) wore eight different modern soft contact lenses. Video was captured and analysed of blink (central and up-gaze), excursion lag (up, down, right and left gaze) and push-up movement, centration and coverage. Results: Lens centration was on average close to the corneal centre. Movement on blink was significantly smaller in up-gaze than in primary-gaze (p<0.001). Lag was greatest in down-gaze and least in up-gaze (p<0.001). Push-up test recovery speed was 1.32±0.73mm/s. Overall lens movement was determined best by assessing horizontal lag, movement on blink in up-gaze and push-up recovery speed. Steeper lens base-curves did not have a significant effect on lens fit characteristics. Contact lens material did influence lens fit characteristics, particularly silicone-hydrogels which generally had lower centration and a faster push-up speed of recovery than HEMA lenses (p<0.05). Conclusion: Lag on vertical gaze, and movement on blink in primary gaze generally provide little extra information on overall lens movement compared to horizontal lag, movement on blink in up gaze and push-up recovery speed. They can therefore be excluded from a simplified recording scheme. A simplified and comprehensive soft contact lens fit recording system could consist of a cross-hairs indicating the centre of the cornea; a circle to indicate the lens centration; a mark on the relevant position of the circle to indicate any limbal incursion; a grade (‘B’) below for movement with blink in up-gaze, a grade (‘L’) to the side for horizontal lag and a grade above (‘P’) for the assessed push-up recovery speed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background There is a paucity of data describing the prevalence of childhood refractive error in the United Kingdom. The Northern Ireland Childhood Errors of Refraction study, along with its sister study the Aston Eye Study, are the first population-based surveys of children using both random cluster sampling and cycloplegic autorefraction to quantify levels of refractive error in the United Kingdom. Methods Children aged 6–7 years and 12–13 years were recruited from a stratified random sample of primary and post-primary schools, representative of the population of Northern Ireland as a whole. Measurements included assessment of visual acuity, oculomotor balance, ocular biometry and cycloplegic binocular open-field autorefraction. Questionnaires were used to identify putative risk factors for refractive error. Results 399 (57%) of 6–7 years and 669 (60%) of 12–13 years participated. School participation rates did not vary statistically significantly with the size of the school, whether the school is urban or rural, or whether it is in a deprived/non-deprived area. The gender balance, ethnicity and type of schooling of participants are reflective of the Northern Ireland population. Conclusions The study design, sample size and methodology will ensure accurate measures of the prevalence of refractive errors in the target population and will facilitate comparisons with other population-based refractive data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To demonstrate the application of low-coherence reflectometry to the study of biometric changes during disaccommodation responses in human eyes after cessation of a near task and to evaluate the effect of contact lenses on low-coherence reflectometry biometric measurements. METHODS: Ocular biometric parameters of crystalline lens thickness (LT) and anterior chamber depth (ACD) were measured with the LenStar device during and immediately after a 5 D accommodative task in 10 participants. In a separate trial, accommodation responses were recorded with a Shin-Nippon WAM-5500 optometer in a subset of two participants. Biometric data were interleaved to form a profile of post-task anterior segment changes. In a further experiment, the effect of soft contact lenses on LenStar measurements was evaluated in 15 participants. RESULTS: In 10 adult participants, increased LT and reduced ACD was seen during the 5 D task. Post-task, during fixation of a 0 D target, a profile of the change in LT and ACD against time was observed. In the two participants with accommodation data (one a sufferer of nearwork-induced transient myopia and other a non-sufferer), the post-task changes in refraction compared favorably with the interleaved LenStar biometry data. The insertion of soft contact lenses did not have a significant effect on LenStar measures of ACD or LT (mean change: -0.007 mm, p = 0.265 and + 0.001 mm, p = 0.875, respectively). CONCLUSIONS: With the addition of a relatively simple stimulus modification, the LenStar instrument can be used to produce a profile of post-task changes in LT and ACD. The spatial and temporal resolution of the system is sufficient for the investigation of nearwork-induced transient myopia from a biometric viewpoint. LenStar measurements of ACD and LT remain valid after the fitting of soft contact lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review describes a group of diseases known as the transmissible spongiform encephalopathies (TSEs), which affect animals and humans. Examination of affected brain tissue suggests that these diseases are caused by the acquisition and deposition of prion protein (PrP). Creutzfeldt-Jakob disease (CJD) is the most important form of TSE in humans with at least four different varieties of the disease. Variant CJD (vCJD), a new form of the disease found in the UK, has several features that differ from the classical forms including early age of onset, longer duration of disease, psychiatric presentation (for example, depression) and extensive florid plaque development in the brain. About 10 per cent of patients with CJD exhibit visual symptoms at disease presentation and approximately 50 per cent during the course of the disease. The most commonly reported visual symptoms include diplopia, supranuclear palsies, complex visual disturbances, homonymous visual field defects, hallucinations and cortical blindness. Saccadic and smooth pursuit movements appear to be more rarely affected. The agent causing vCJD accumulates in lymphoid tissue such as the spleen and tonsils. The cornea has lymphoid tissue in the form of corneal dendritic cells that are important in the regulation of the immune response in the anterior segment of the eye. The presence of these cells in the cornea has raised the possibility of transmission between patients via optical devices that contact the eye. Although such transmission is theoretically possible it remains highly improbable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the importance of oxygen measurements, techniques have been limited by their invasive nature and small corneal area of assessment. The aim of this study was to assess a non-contact way of measuring oxygen uptake of the whole anterior eye.