37 resultados para Subjective and objective hearing protection evaluation method
Resumo:
Concept evaluation at the early phase of product development plays a crucial role in new product development. It determines the direction of the subsequent design activities. However, the evaluation information at this stage mainly comes from experts' judgments, which is subjective and imprecise. How to manage the subjectivity to reduce the evaluation bias is a big challenge in design concept evaluation. This paper proposes a comprehensive evaluation method which combines information entropy theory and rough number. Rough number is first presented to aggregate individual judgments and priorities and to manipulate the vagueness under a group decision-making environment. A rough number based information entropy method is proposed to determine the relative weights of evaluation criteria. The composite performance values based on rough number are then calculated to rank the candidate design concepts. The results from a practical case study on the concept evaluation of an industrial robot design show that the integrated evaluation model can effectively strengthen the objectivity across the decision-making processes.
Resumo:
Cyclothialidine, a natural product isolated from Streptomyces .filipinensis NR0484, has been proven to be a potent and selective inhibitor of the bacterial enzyme DNA gyrase. Gyrase inhibition results in cell death, the enzyme being the target of several currently used antibiotics. Cyclothialidine showed poor activity against whole bacterial cells, highlighting scope for improvement regarding cell membrane pemeability in order for the full potential of this new class of antibiotics to be realised, Structurally, cyclothialidine contains a 12-membered lactone ring which is partly integrated into a pentapeptide chain, with a substituted aromatic moiety bordering the lactone, Retrosynthetically it can be traced back to cis-3-hydroxyproline, 3,5-dihydroxy-2,6-dimethylbenzoic acid and four commercially available amino acids; two serine, one cysteine and one alanine. In this work, a model of cyclothialidine was synthesised in order to establish the methodology for more complex compounds. Analogues with hydroxy, dihydroxy and dihydroxymethyl substituted aromatic moieties were then prepared to ensure successful protection methods could be performed and the pharmacophore synthesised. The key aromatic moiety, 2,6-dimethyl-3,5-dihydroxybenzoic acid was produced via two successive Mannich reaction/reduction steps. Acid protection using 4-nitrobenzyl bromide and TBDMS hydroxyl protection followed by bromination of one methyl afforded the desired intermediate. Reaction with a serine/cysteine dipeptide, followed by deprotection and cyclisation under Mitsunobu conditions lead to the 12-membered lactone. An amine substituted aromatic analogue and also replacement of the cysteine sulphur by oxygen were attempted but without success. In an effort to improve cell permeability, a conjugate was synthesised between the pharmacophore and a cholesterol moiety. It was hoped the steroid fragment would serve to increase potency by escorting the molecule through the lipid environment of the cell membrane. The pharmacophore and conjugate were tested against a variety of bacterial strains but the conjugate failed to improve activity.
Resumo:
Background: The aim was to evaluate the validity and repeatability of the auto-refraction function of the Nidek OPD-Scan III (Nidek Technologies, Gamagori, Japan) compared with non-cycloplegic subjective refraction. The Nidek OPD-Scan III is a new aberrometer/corneal topographer workstation based on the skiascopy principle. It combines a wavefront aberrometer, topographer, autorefractor, auto keratometer and pupillometer/pupillographer. Methods: Objective refraction results obtained using the Nidek OPD-Scan III were compared with non-cycloplegic subjective refraction for 108 eyes of 54 participants (29 female) with a mean age of 23.7±9.5 years. Intra-session and inter-session variability were assessed on 14 subjects (28 eyes). Results: The Nidek OPD-Scan III gave slightly more negative readings than results obtained by subjective refraction (Nidek mean difference -0.19±0.36 DS, p<0.01 for sphere; -0.19±0.35 DS, p<0.01 for mean spherical equivalent; -0.002±0.23 DC, p=0.91 for cylinder; -0.06±0.38 DC, p=0.30 for J0 and -0.36±0.31 DC for J45, p=0.29). Auto-refractor results for 74 per cent of spherical readings and 60 per cent of cylindrical powers were within±0.25 of subjective refraction. There was high intra-session and inter-session repeatability for all parameters; 90 per cent of inter-session repeatability results were within 0.25 D. Conclusion: The Nidek OPD-Scan III gives valid and repeatable measures of objective refraction when compared with non-cycloplegic subjective refraction. © 2013 The Authors. Clinical and Experimental Optometry © 2013 Optometrists Association Australia.
Resumo:
Internal quantum efficiency (IQE) of a high-brightness blue LED has been evaluated from the external quantum efficiency measured as a function of current at room temperature. Processing the data with a novel evaluation procedure based on the ABC-model, we have determined separately IQE of the LED structure and light extraction efficiency (LEE) of UX:3 chip. Full text Nowadays, understanding of LED efficiency behavior at high currents is quite critical to find ways for further improvement of III-nitride LED performance [1]. External quantum efficiency ηe (EQE) provides integral information on the recombination and photon emission processes in LEDs. Meanwhile EQE is the product of IQE ηi and LEE ηext at negligible carrier leakage from the active region. Separate determination of IQE and LEE would be much more helpful, providing correlation between these parameters and specific epi-structure and chip design. In this paper, we extend the approach of [2,3] to the whole range of the current/optical power variation, providing an express tool for separate evaluation of IQE and LEE. We studied an InGaN-based LED fabricated by Osram OS. LED structure grown by MOCVD on sapphire substrate was processed as UX:3 chip and mounted into the Golden Dragon package without molding. EQE was measured with Labsphere CDS-600 spectrometer. Plotting EQE versus output power P and finding the power Pm corresponding to EQE maximum ηm enables comparing the measurements with the analytical relationships ηi = Q/(Q+p1/2+p-1/2) ,p = P/Pm , and Q = B/(AC) 1/2 where A, Band C are recombination constants [4]. As a result, maximum IQE value equal to QI(Q+2) can be found from the ratio ηm/ηe plotted as a function of p1/2 +p1-1/2 (see Fig.la) and then LEE calculated as ηext = ηm (Q+2)/Q . Experimental EQE as a function of normalized optical power p is shown in Fig. 1 b along with the analytical approximation based on the ABCmodel. The approximation fits perfectly the measurements in the range of the optical power (or operating current) variation by eight orders of magnitude. In conclusion, new express method for separate evaluation of IQE and LEE of III-nitride LEDs is suggested and applied to characterization of a high-brightness blue LED. With this method, we obtained LEE from the free chip surface to the air as 69.8% and IQE as 85.7% at the maximum and 65.2% at the operation current 350 rnA. [I] G. Verzellesi, D. Saguatti, M. Meneghini, F. Bertazzi, M. Goano, G. Meneghesso, and E. Zanoni, "Efficiency droop in InGaN/GaN blue light-emitting diodes: Physical mechanisms and remedies," 1. AppL Phys., vol. 114, no. 7, pp. 071101, Aug., 2013. [2] C. van Opdorp and G. W. 't Hooft, "Method for determining effective non radiative lifetime and leakage losses in double-heterostructure lasers," 1. AppL Phys., vol. 52, no. 6, pp. 3827-3839, Feb., 1981. [3] M. Meneghini, N. Trivellin, G. Meneghesso, E. Zanoni, U. Zehnder, and B. Hahn, "A combined electro-optical method for the determination of the recombination parameters in InGaN-based light-emitting diodes," 1. AppL Phys., vol. 106, no. II, pp. 114508, Dec., 2009. [4] Qi Dai, Qifeng Shan, ling Wang, S. Chhajed, laehee Cho, E. F. Schubert, M. H. Crawford, D. D. Koleske, Min-Ho Kim, and Yongjo Park, "Carrier recombination mechanisms and efficiency droop in GalnN/GaN light-emitting diodes," App/. Phys. Leu., vol. 97, no. 13, pp. 133507, Sept., 2010. © 2014 IEEE.
Resumo:
Objectives: To develop a tool for the accurate reporting and aggregation of findings from each of the multiple methods used in a complex evaluation in an unbiased way. Study Design and Setting: We developed a Method for Aggregating The Reporting of Interventions in Complex Studies (MATRICS) within a gastroenterology study [Evaluating New Innovations in (the delivery and organisation of) Gastrointestinal (GI) endoscopy services by the NHS Modernisation Agency (ENIGMA)]. We subsequently tested it on a different gastroenterology trial [Multi-Institutional Nurse Endoscopy Trial (MINuET)]. We created three layers to define the effects, methods, and findings from ENIGMA. We assigned numbers to each effect in layer 1 and letters to each method in layer 2. We used an alphanumeric code based on layers 1 and 2 to every finding in layer 3 to link the aims, methods, and findings. We illustrated analogous findings by assigning more than one alphanumeric code to a finding. We also showed that more than one effect or method could report the same finding. We presented contradictory findings by listing them in adjacent rows of the MATRICS. Results: MATRICS was useful for the effective synthesis and presentation of findings of the multiple methods from ENIGMA. We subsequently successfully tested it by applying it to the MINuET trial. Conclusion: MATRICS is effective for synthesizing the findings of complex, multiple-method studies.
Resumo:
Objective: The Any Qualified Provider framework in the National Health Service has changed the way adult audiology services are offered in England. Under the new rules, patients are being offered a choice in geographical location and audiology provider. This study aimed to explore how choices in treatment are presented and to identify what information patients need when they are seeking help with hearing loss. Design: This study adopted qualitative methods of ethnographic observations and focus group interviews to identify information needed prior to, and during, help-seeking. Observational data and focus group data were analysed using the constant comparison method of grounded theory. Study sample: Participants were recruited from a community Health and Social Care Trust in the west of England. This service incorporates both an Audiology and a Hearing Therapy service. Twenty seven participants were involved in focus groups or interviews. Results: Participants receive little information beyond the detail of hearing aids. Participants report little information that was not directly related to uptake of hearing aids. Conclusions: Participant preferences were not explored and limited information resulted in decisions that were clinician-led. The gaps in information reflect previous data on clinician communication and highlight the need for consistent information on a range of interventions to manage hearing loss.
Resumo:
OBJECTIVE: This study aimed to assess prevalence and risk factors for mild/high-frequency bilateral sensorineural hearing loss within a UK population of children at age 11 years. DESIGN: Prospective birth cohort study. STUDY SAMPLE: Repeat hearing thresholds were measured in 5032 children, as part of the Avon Longitudinal Study of Parents and Children (ALSPAC) at age 7, 9, and 11 years. Pregnancy, birth, and early medical history were obtained prospectively through parental questionnaires and medical records. RESULTS: Twenty children had mild and seven had high-frequency bilateral sensorineural hearing loss, giving a combined prevalence of 0.5% (95% CI 0.4-0.8%). These children were more likely than the rest of the study sample to have been admitted to hospital at 6-18 months (OR 2.7, 95% CI 1.00-7.30). Parents of these children were more likely to have suspected a hearing problem when the children were 3 years old (OR 2.4, 95% CI 1.05-5.60). CONCLUSIONS: This is the first UK prospective cohort study to investigate the prevalence of mild and high-frequency hearing loss. This study, which has the advantage of a large sample size and repeat hearing measures over a four year period, reports lower prevalence values than US cross-sectional studies.