45 resultados para Strain and stress fields


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a demultiplexing scheme for fibre optic Bragg grating sensors in which signal recovery is achieved by locking each sensor grating to a corresponding receiver grating. As a demonstration, the technique is applied to strain and temperature sensing, achieving a resolution of 3.0 µe and 0.2°C, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Interferometric sensors using optical fibers as a transduction medium have been shown to be sensitive to a variety of physical measurands. A result of this is that the resolution of a system designed to sense strain, for example, may be compromised by fluctuations in the temperature of the environment. The possibility of simultaneously determining the strain and temperature applied to the same piece of highly birefringent fiber is discussed. Second-order effects are shown to be important for long sensing lengths or in the presence of high strains or temperature changes. The results of experiments carried out to verify the theoretical predictions are also described.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new family of commercial zinc alloys designated as ZA8, ZA12, and ZA27 and high damping capacity alloys including Cosmal and Supercosmal and aluminium alloy LM25 were investigated for compressive creep and load relaxation behaviour under a series of temperatures and stresses. A compressive creep machine was designed to test the sand cast hollow cylindrical test specimens of these alloys. For each compressive creep experiment the variation of creep strain was presented in the form of graphs plotted as percentage of creep strain () versus time in seconds (s). In all cases, the curves showed the same general form of the creep curve, i.e. a primary creep stage, followed by a linear steady-state region (secondary creep). In general, it was observed that alloy ZA8 had the least primary creep among the commercial zinc-based alloys and ZA27 the greatest. The extent of primary creep increased with aluminium content to that of ZA27 then declined to Supercosmal. The overall creep strength of ZA27 was generally less than ZA8 and ZA12 but it showed better creep strength than ZA8 and ZA12 at high temperature and high stress. In high damping capacity alloys, Supercosmal had less primary creep and longer secondary creep regions and also had the lowest minimum creep rate among all the tested alloys. LM25 exhibited almost no creep at maximum temperature and stress used in this research work. Total creep elongation was shown to be well correlated using an empirical equation. Stress exponent and activation energies were calculated and found to be consistent with the creep mechanism of dislocation climb. The primary α and β phases in the as-cast structures decomposed to lamellar phases on cooling, with some particulates at dendrite edges and grain boundaries. Further breakdown into particulate bodies occurred during creep testing, and zinc bands developed at the highest test temperature of 160°C. The results of load relaxation testing showed that initially load loss proceeded rapidly and then deminished gradually with time. Load loss increased with temperature and almost all the curves approximated to a logarithmic decay of preload with time. ZA alloys exhibited almost the same load loss at lower temperature, but at 120°C ZA27 improved its relative performance with the passage of time. High damping capacity alloys and LM25 had much better resistance to load loss than ZA alloys and LM25 was found to be the best against load loss among these alloys. A preliminary equation was derived to correlate the retained load with time and temperature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This thesis investigates the soil-pipeline interactions associated with the operation of large-diameter chilled gas pipelines in Britain, these are frost/pipe heave and ground cracking. The investigation was biased towards the definition of the mechanism of ground cracking and, the parameters which influence its generation and subsequent development, especially its interaction with frost heave. The study involved a literature review, questionnaire, large-scale test and small-scale laboratory model experiments. The literature review concentrated on soil-pipeline interactions and frost action, with frost/pipe heave often reported but ground cracking was seldom reported. A questionnaire was circulated within British Gas to gain further information on these interactions. The replies indicated that if frost/pipe heave was reported, ground cracking was also likely to be observed. These soil-pipeline interactions were recorded along 19% of pipelines in the survey and were more likely along the larger diameter, higher flow pipelines. A large-scale trial along a 900 mm pipeline was undertaken to assess the soil thermal, hydraulic and stress regimes, together with pipe and ground movements. Results indicated that cracking occurred intermittently along the pipeline during periods of rapid frost/pipe heave and ground movement and, that frozen annulus growth produced a ground surface profile was approximated by a normal probability distribution curve. This curve indicates maximum tensile strain directly over the pipe centre. Finally a small-scale laboratory model was operated to further define the ground cracking mechanism. Ground cracking was observed at small upward ground surface movement, and with continued movement the ground crack increased in width and depth. At the end of the experiments internal soil failure planes slanting upwards and away from the frozen annulus were noted. The suggested mechanism for ground cracking involved frozen annulus growth producing tensile strain in the overlying unfrozen soil, which when sufficient produced a crack.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hydrocarbons are the most common form of energy used to date. The activities involving exploration and exploitation of large oil and gas fields are constantly in operation and have extended to such hostile environments as the North Sea. This enforces much greater demands on the materials which are used, and the need for enhancing the endurance of the existing ones which must continue parallel to the explorations. Due to their ease in fabrication, relatively high mechanical properties and low costs, steels are the most widely favoured material for the construction of offshore platforms. The most critical part of an offshore structure prone to failure are the welded nodal joints, particulary those which are used within the vicinity of the splash zones. This is an area of high complex stress concentrations, varying mechanical and metallurgical properties in addition to severe North Sea environmental conditions. The main are of this work has been concerned with the durability studies of this type of steel, based on the concept of the worst case analysis, consisting of combinations of welds of varying qualities, various degrees of stress concentrations and the environmental conditions of stress corrosion and hydrogen embrittlement. The experiments have been designed to reveal significance of defects as sites of crack initiation in the welded steels and the extent to which stress corrosion and hydrogen embrittlement will limit their durability. This has been done for various heat treatments and in some experiments deformation has been forced through the welded zone of the specimens to reveal the mechanical properties of the welds themselves to provide data for finite element simulations. A comparison of the results of these simulations with the actual deformation and fracture behaviour has been done to reveal the extent to which both mechanical and metallurgical factors control behaviour of the steels in the hostile environments of high stress, corrosion, and hydrogen embrittlement at their surface.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fabrication of in-fibre Bragg gratings, and the application of arrays of such gratings as strain sensors and as true time delay elements for the control of phased array antennas is reported. Chirped period Bragg gratings were produced using the fibre deformation fabrication technique, with chirps of between 2.9nm and 17.3nm achieved. Arrays of 5mm and 2mm long uniform period Bragg gratings were fabricated using the inscription method, for use as true time delay elements,dissimilar wavefronts and their spectral characteristics recorded. The uniform period grating arrays were used to create minimum time delays of 9.09ps, 19.02ps and 31ps; making them suitable for controlling phased array antennas operating at RF frequencies of up to 3GHz, with 10° phase resolution. Four 4mm long chirped gratings were produced using the dissimilar wavefronts fabrication method, having chirps of 7nm, 12nm, 20nm and 30nm, and were used to create time delays of between 0.3ps and 59ps. Hence they are suitable for controlling phased array antennas at RF frequencies of up to 48GHz. The application of in fibre Bragg gratings as strain sensors within smart structure materials was investigated, with their sensitivity to applied strain and compression measured for both embedded and surface mounted uniform period and fibre Fabry-Perot filter gratings. A fibre Bragg grating sensor demultiplexing scheme based on a liquid crystal filled Fabry-Perot etalon tuneable transmission filter was proposed, successfully constructed and fully characterised. Three characteristics of the LCFP etalon were found to pose operational limitations to its application in a Bragg grating sensor system; most significantly, the resonance peak wavelength was highly (-2,77nm/°C) temperature dependent. Several methods for minimising this temperature sensitivity were investigated, but enjoyed only limited success. It was therefore concluded that this type (E7 filled) of LCFP etalon is unsuitable for use as a Bragg grating sensor demultiplexing element.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Food allergy is related to poorer quality of life (QoL) and mental health of caregivers. Many parents diagnose food allergy in their child without seeking medical care and there is limited research on this group. This study investigated parental QoL and mental health in parents of children with parent-diagnosed food allergy (PA), medically diagnosed food allergy (MA), and a control group with no allergy (NA). Methods. One hundred and fifty parents from a general population completed validated measures of QoL, anxiety, depression, and stress. Results. Parents of children with food allergy (PA or MA) reported higher stress, anxiety, and depression than the control group (all ). Parents of children with MA reported poorer food allergy related QoL compared to parents of children with PA (); parents of children with PA reported poorer general QoL compared to parents of children with MA (). Conclusion. Parents of children with food allergy have significantly poorer mental health compared to healthy controls, irrespective of whether food allergy is medically diagnosed or not. It is important to encourage parents to have their child medically tested for food allergy and to recognise and refer for psychological support where needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Peanut allergy (PA) is known to impact on quality of life (QoL) of the sufferer, but little research has focused on all family members. We therefore sought to establish the impact of PA on QoL and reported anxiety of children with clinically confirmed PA, their parents and older siblings. Methods: Forty-six families, who had a child with PA, completed QoL (PedsQLTM or WHOQOL-BREF), anxiety (SCAS or STAI) and perceived stress (PSS) scales. PA children completed a PA specific QoL questionnaire (Pediatr Allergy Immunol 2003;14:378). Parents and sibling also completed QoL proxy questionnaires for the PA child (PedsQLTM, Pediatr Allergy Immunol 2003;14:378). Results: Mothers rated their own psychological (P < 0.01) and physical (P < 0.05) QoL significantly worse than fathers rated theirs, and had higher scores than fathers for anxiety (P < 0.05) and stress (P < 0.001). Children with PA had significantly poorer physical health-related QoL (P < 0.05), QoL within school (P < 0.01) and general QoL (P < 0.05) than their siblings did, and greater separation anxiety (P < 0.05). The majority of differences were between girls with PA and female siblings. Mothers felt that there was a greater impact on QoL for their PA child, compared with that reported by siblings, fathers or the PA children themselves (P < 0.01). Conclusions: Mothers report that they have significantly poorer QoL and suffer more anxiety and stress than fathers do; this inter-parental difference may be an important feature of family stress caused by PA. Siblings have a similar view of how QoL affects the PA child as the PA child does, while mothers may possibly overestimate this impact.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper introduces a theoretical framework to guide research into the psychological effects of advanced manufacturing technology (AMT) on shopfloor operators. The framework has two main aspects. First, based on the emerging literature on the job content implications of AMT, it identifies four key constructs, namely: control, cognitive demand, production responsibility and social interaction. Second, by drawing on the more established job design, stress and related literatures, it predicts how these independent variables differentially affect system performance, job-related strain and job satisfaction. The wider implications and limitations of the theoretical framework are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we report on the strain and pressure testing of highly flexible skins embedded with Bragg grating sensors recorded in either silica or polymer optical fibre. The photonic skins, with a size of 10cm x 10cm and thickness of 1mm, were fabricated by embedding the polymer fibre or silica fibre containing Bragg gratings in Sylgard 184 from Dow Corning. Pressure sensing was studied using a cylindrical metal post placed on an array of points across the skin. The polymer fibre grating exhibits approximately 10 times the pressure sensitivity of the silica fibre and responds to the post even when it is placed a few centimetres away from the sensing fibre. Although the intrinsic strain sensitivities of gratings in the two fibre types are very similar, when embedded in the skin the polymer grating displayed a strain sensitivity approximately 45 times greater than the silica device, which also suffered from considerable hysteresis. The polymer grating displayed a near linear response over wavelength shifts of 9nm for 1% strain. The difference in behaviour we attribute to the much greater Young's modulus of the silica fibre (70 GPa) compared to the polymer fibre (3 GPa).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We describe a demultiplexing scheme for fibre optic Bragg grating sensors in which signal recovery is achieved by locking each sensor grating to a corresponding receiver grating. As a demonstration, the technique is applied to strain and temperature sensing, achieving a resolution of 3.0 µe and 0.2°C, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effects of a thermal residual stress field on fatigue crack growth in a silicon carbide particle-reinforced aluminum alloy have been measured. Stress fields were introduced into plates of material by means of a quench from a solution heat-treatment temperature. Measurements using neutron diffraction have shown that this introduces an approximately parabolic stress field into the plates, varying from compressive at the surfaces to tensile in the center. Long fatigue cracks were grown in specimens cut from as-quenched plates and in specimens which were given a stress-relieving overaging heat treatment prior to testing. Crack closure levels for these cracks were determined as a function of the position of the crack tip in the residual stress field, and these are shown to differ between as-quenched and stress-relieved samples. By monitoring the compliance of the specimens during fatigue cycling, the degree to which the residual stresses close the crack has been evaluated. © 1995 The Minerals, Metals & Material Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ODTs have emerged as a novel oral dosage form with a potential to deliver a wide range of drug candidates to paediatric and geriatric patients. Compression of excipients offers a costeffective and translatable methodology for the manufacture of ODTs. Though, technical challenges prevail such as difficulty to achieve suitable tablet mechanical strength while ensuring rapid disintegration in the mouth, poor compressibility of preferred ODT diluent Dmannitol, and limited use for modified drug-release. The work investigates excipients’ functionality in ODTs and proposes new methodologies for enhancing material characteristics via process and particle engineering. It also aims to expand ODT applications for modified drug-release. Preformulation and formulation studies employed a plethora of techniques/tests including AFM, SEM, DSC, XRD, TGA, HSM, FTIR, hardness, disintegration time, friability, stress/strain and Heckel analysis. Tableting of D-mannitol and cellulosic excipients utilised various compression forces, material concentrations and grades. Engineered D-mannitol particles were made by spray drying mannitol with pore former NH4HCO3. Coated microparticles of model API omeprazole were prepared using water-based film forming polymers. The results of nanoscopic investigations elucidated the compression profiles of ODT excipients. Strong densification of MCC (Py is 625 MPa) occurs due to conglomeration of physicomechanical factors whereas D-mannitol fragments under pressure leading to poor compacts. Addition of cellulosic excipients (L-HPC and HPMC) and granular mannitol to powder mannitol was required to mechanically strengthen the dosage form (hardness >60 N, friability <1%) and to maintain rapid disintegration (<30 sec). Similarly, functionality was integrated into D-mannitol by fabrication of porous, yet, resilient particles which resulted in upto 150% increase in the hardness of compacts. The formulated particles provided resistance to fracture under pressure due to inherent elasticity while promoted tablet disintegration (50-77% reduction in disintegration time) due to porous nature. Additionally, coated microparticles provided an ODT-appropriate modified-release coating strategy by preventing drug (omeprazole) release.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We demonstrate highly sensitive temperature and strain sensors based on an all-fiber Lyot filter structure, which is formed by concatenating two 45°-TFGs (tilted fiber gratings) with a PM fiber cavity. The experiment results show the all-fiber 45°-TFG Lyot filter has very high sensitivity to strain and temperature. The 45°-TFG Lyot filters of two different cavity lengths (18cm and 40 cm) have been evaluated for temperature sensing by heating a section of the cavity from 10°C to 50°C. The experiment results have shown remarkably high temperature sensitivities of 0.616nm/°C for 18cm and 0.31nm/°C for 40cm long cavity filter, respectively. The 18cm long cavity filter has been subjected to strain variations up to around 550μ ε and the filter has exhibited strain sensitivities of 0.02499nm/μ ε and 0.012nm/μ ε for two straining situations, where its cavity middle section of 18cm and 9cm were stretched, respectively. © 2012 SPIE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Doctors and nurses working at the accident and emergency (A&E), and intensive care departments are at risk of burnout. They often spend substantial time in intense interactions with other people, centered on patients? health problems (physical, psychological and social) that may lead to feelings of anger, anxiety and frustration, and eventually to burnout. Burnout is a syndrome of emotional exhaustion, depersonalization and reduced personal accomplishment (Maslach & Jackson, 1981) The purpose of this chapter is to assess work stressors, burnout and stress-coping mechanisms among doctors and nurses at the A&E and intensive care departments. A quantitative design using the survey approach was used to collect data from a sample of 200 participants with a response rate of 71% (n=154) Work stressors were associated with burnout in both doctors and nurses. Workload was the most salient work stressor in the sample. Nurses experienced more stress (M=1.5, SD=0.4) than doctors (M=1.2, SD=0.4) in all the work stressor variables examined. The A&E department was reported as more stressful than the intensive care department. Avoidance-oriented and task-oriented coping were the most and the least frequently reported coping strategies respectively. Additionally, only emotion-oriented coping strategy was significantly different between doctors and nurses, and this strategy was also significantly positively correlated with all the variables in the adapted nursing stress scale, and the three burnout variables. Death and dying was most strongly correlated with emotion-oriented coping. This chapter provides an assessment of stress, burnout and coping experienced by both doctors and nurses within the A&E and intensive care departments. Methods that may mitigate stress in these environments may be adequate staffing, supportive management, stress management programs, as well as improvement in communication strategies between doctors and nurses.