35 resultados para Sentencing disparity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction - Lower success rates of in vitro fertilisation (IVF) in South East Asian countries compared to Western countries in informal studies and surveys was considered a reflection of variations in methodology and expertise. However, recent studies on the effects of ethnicity on success rates of infertility procedures in western countries have suggested other inherent contributing factors to the ethnic disparity but the evidence evaluating these is lacking. In our study we aim to investigate some of the comorbidities that might cause ethnic disparity to infertility and related procedures from hospital admissions data. Methods - Anonymous hospital admissions data on patients of various ethnic groups with infertility, comorbidities and infertility procedures from multiple hospitals in Birmingham andManchester, UK between 2000 and 2013 were obtained from the local health authority computerised hospital activity analysis register using ICD-10 and OPCS coding systems. Statistical analysis was performed using SPSS version 20.Results Of 522 223 female patients aged 18 and over, there were44 758 (8.4%) patients from South Asian (SA) community. 1156(13.4%) of the 8653 patients coded for infertility were SA, whichis a considerably higher proportion of the background SA population. For IVF procedures, the percentage of SA increased to15.4% (233 of the total 1479 patients). The mean age of SA codedfor infertility (30.6 ± 4.7 SD years versus 32.8 ± 4.9 SD years)and IVF (30.4 ± 4.3 SD years versus 32.7 ± 4.4 SD years) was significantly lower than caucasian patien ts (P < 0.001). A multivariate logistic regression model looking at patients with infertility, accounting for variations in age, showed that SA have significantly higher prevalence of hypothyroidism, obesity andiron-deficiency anaemia compared to caucasians but lower prevalence of endometriosis. Interestingly, psychiatric and psychological conditions diagnoses were seldom registered in infertility patients. Conclusion - Other studies suggest that various cultural, lifestyles, psychosocial and socio-economic factors may explain the disparities in IVF success rates between South Asians and caucasians. The fact that SA infertility and IVF patients, in ou rstudy, were significantly younger than caucasians and that their proportion is considerably higher than the background South Asian population suggests the influence of these factors. A significant psychiatric disease burden in other conditions and low numbers in our data suggest under diagnosis in this group.Despite the limitations of the coding data, from our study, we propose that hypothyroidism, obesity and/or iron-deficiency anaemia should be considered for the ethnic disparity. Further research in this topic is essential to fully investigate the reasons for such ethnic disparities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simple features such as edges are the building blocks of spatial vision, and so I ask: how arevisual features and their properties (location, blur and contrast) derived from the responses ofspatial filters in early vision; how are these elementary visual signals combined across the twoeyes; and when are they not combined? Our psychophysical evidence from blur-matchingexperiments strongly supports a model in which edges are found at the spatial peaks ofresponse of odd-symmetric receptive fields (gradient operators), and their blur B is givenby the spatial scale of the most active operator. This model can explain some surprisingaspects of blur perception: edges look sharper when they are low contrast, and when theirlength is made shorter. Our experiments on binocular fusion of blurred edges show that singlevision is maintained for disparities up to about 2.5*B, followed by diplopia or suppression ofone edge at larger disparities. Edges of opposite polarity never fuse. Fusion may be served bybinocular combination of monocular gradient operators, but that combination - involvingbinocular summation and interocular suppression - is not completely understood.In particular, linear summation (supported by psychophysical and physiological evidence)predicts that fused edges should look more blurred with increasing disparity (up to 2.5*B),but results surprisingly show that edge blur appears constant across all disparities, whetherfused or diplopic. Finally, when edges of very different blur are shown to the left and righteyes fusion may not occur, but perceived blur is not simply given by the sharper edge, nor bythe higher contrast. Instead, it is the ratio of contrast to blur that matters: the edge with theAbstracts 1237steeper gradient dominates perception. The early stages of binocular spatial vision speak thelanguage of luminance gradients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The visual system combines spatial signals from the two eyes to achieve single vision. But if binocular disparity is too large, this perceptual fusion gives way to diplopia. We studied and modelled the processes underlying fusion and the transition to diplopia. The likely basis for fusion is linear summation of inputs onto binocular cortical cells. Previous studies of perceived position, contrast matching and contrast discrimination imply the computation of a dynamicallyweighted sum, where the weights vary with relative contrast. For gratings, perceived contrast was almost constant across all disparities, and this can be modelled by allowing the ocular weights to increase with disparity (Zhou, Georgeson & Hess, 2014). However, when a single Gaussian-blurred edge was shown to each eye perceived blur was invariant with disparity (Georgeson & Wallis, ECVP 2012) – not consistent with linear summation (which predicts that perceived blur increases with disparity). This blur constancy is consistent with a multiplicative form of combination (the contrast-weighted geometric mean) but that is hard to reconcile with the evidence favouring linear combination. We describe a 2-stage spatial filtering model with linear binocular combination and suggest that nonlinear output transduction (eg. ‘half-squaring’) at each stage may account for the blur constancy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Traditionally, it has been thought that no binocular combination occurs in amblyopia. However, there is a growing body of evidence that there are intact binocular mechanisms in amblyopia rendered inactive under normal viewing conditions due to imbalanced monocular inputs. Georgeson and Wallis (2014) recently introduced a novel method to investigate fusion, suppression and diplopia in normal population. We have modified this method to assess binocular interactions in amblyopia. Methods: Ten amblyopic and ten control subjects viewed briefly-presented (200 ms) pairs of dichoptically separated horizontal Gaussian blurred edges. Subjects reported one central edge, one offset edge, or a double edge as the vertical disparity was manipulated. The experiment was conducted at a range of spatial scales (blur widths of 4, 8, 16, and 32 arc min) and contrasts. Our model, based Georgeson and Wallis (2014), converted subjects’ responses into probabilities of fusion, suppression, and diplopia. Results: When the normal participants were presented equal contrast to each eye the probability of fusion gradually decreased with increasing disparity, as the probability of diplopia gradually increased. In only a small proportion of the trials, normal participants experienced suppression. The pattern was consistent across all edge blurs. Interestingly, the majority of amblyopes had a comparable pattern of fusion, i.e. decreasing probability with increasing disparity. However, with increasing disparity the amblyopes tended to suppress the amblyopic eye, experiencing diplopia only in a small proportion of trials particularly at large blurs. Increasing the interocular contrast offset favouring the amblyopic eye normalized the pattern of data in a way similar to normal participants. There were some interesting exceptions: strong suppressors for which our contrast range was inadequate and one case in which diplopia dominated. Conclusions: This task is suitable for assessing binocular interactions in amblyopic participants and providing a way to quantify the relationship between fusion, suppression and diplopia. In agreement with previous studies, our data indicate the presence of binocular mechanisms in amblyopia. A contrast offset favouring the amblyopic eye normalizes the measured binocular interactions in the amblyopic visual system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bladder cancer is among the most common cancers in the UK and conventional detection techniques suffer from low sensitivity, low specificity, or both. Recent attempts to address the disparity have led to progress in the field of autofluorescence as a means to diagnose the disease with high efficiency, however there is still a lot not known about autofluorescence profiles in the disease. The multi-functional diagnostic system "LAKK-M" was used to assess autofluorescence profiles of healthy and cancerous bladder tissue to identify novel biomarkers of the disease. Statistically significant differences were observed in the optical redox ratio (a measure of tissue metabolic activity), the amplitude of endogenous porphyrins and the NADH/porphyrin ratio between tissue types. These findings could advance understanding of bladder cancer and aid in the development of new techniques for detection and surveillance.