35 resultados para Sensorless control scheme
Resumo:
This paper proposes a methodological scheme for the photovoltaic (PV) simulator design. With the advantages of a digital controller system, linear interpolation is proposed for precise fitting with higher computational efficiency. A novel control strategy that directly tackles two different duty cycles is proposed and implemented to achieve a full-range operation including short circuit (SC) and open circuit (OC) conditions. Systematic design procedures for both hardware and algorithm are explained, and a prototype is built. Experimental results confirm an accurate steady state performance under different load conditions, including SC and OC. This low power apparatus can be adopted for PV education and research with a limited budget.
Resumo:
There is an emerging application which uses a mixture of batteries within an energy storage system. These hybrid battery solutions may contain different battery types. A DC-side cascaded boost converters along with a module based distributed power sharing strategy has been proposed to cope with variations in battery parameters such as, state-of-charge and/or capacity. This power sharing strategy distributes the total power among the different battery modules according to these battery parameters. Each module controller consists of an outer voltage loop with an inner current loop where the desired control reference for each control loop needs to be dynamically varied according to battery parameters to undertake this sharing. As a result, the designed control bandwidth or stability margin of each module control loop may vary in a wide range which can cause a stability problem within the cascaded converter. This paper reports such a unique issue and thoroughly investigates the stability of the modular converter under the distributed sharing scheme. The paper shows that a cascaded PI control loop approach cannot guarantee the system stability throughout the operating conditions. A detailed analysis of the stability issue and the limitations of the conventional approach are highlighted. Finally in-depth experimental results are presented to prove the stability issue using a modular hybrid battery energy storage system prototype under various operating conditions.
Resumo:
High-volume capacitance is required to buffer the power difference between the input and output ports in single-phase grid-connected photovoltaic inverters, which become an obstacle to high system efficiency and long device lifetime. Furthermore, total harmonic distortion becomes serious when the system runs into low power level. In this study, a comprehensive analysis is introduced for two-stage topology with the consideration of active power, DC-link (DCL) voltage, ripple and capacitance. This study proposed a comprehensive DCL voltage control strategy to minimise the DCL capacitance while maintaining a normal system operation. Furthermore, the proposed control strategy is flexible to be integrated with the pulse-skipping control that significantly improves the power quality at light power conditions. Since the proposed control strategy needs to vary DCL voltage, an active protection scheme is also introduced to prevent any voltage violation across the DCL. The proposed control strategy is evaluated by both simulation and experiments, whose results confirm the system effectiveness.
Resumo:
A novel open-winding brushless doubly-fed generator (BDFG) system with two two-level bidirectional converters is proposed. This topology is equivalent to a three-level bidirectional converter connected to the typical BDFG, but solves the unbalanced-voltage-division problem of DC capacitor in the three-level converter, and has lower converter capacity, more flexible control mode, and better fault-tolerant ability. The direct power control (DPC) based on the twelve sections is adopted to implement the power tracking of the open-winding BDFG system, which is compared with the typical BDFG DPC system based on the six and twelve sections to verify the advantages of the proposed scheme.
Resumo:
Erasure control coding has been exploited in communication networks with an aim to improve the end-to-end performance of data delivery across the network. To address the concerns over the strengths and constraints of erasure coding schemes in this application, we examine the performance limits of two erasure control coding strategies, forward erasure recovery and adaptive erasure recovery. Our investigation shows that the throughput of a network using an (n, k) forward erasure control code is capped by r =k/n when the packet loss rate p ≤ (te/n) and by k(l-p)/(n-te) when p > (t e/n), where te is the erasure control capability of the code. It also shows that the lower bound of the residual loss rate of such a network is (np-te)/(n-te) for (te/n) < p ≤ 1. Especially, if the code used is maximum distance separable, the Shannon capacity of the erasure channel, i.e. 1-p, can be achieved and the residual loss rate is lower bounded by (p+r-1)/r, for (1-r) < p ≤ 1. To address the requirements in real-time applications, we also investigate the service completion time of different schemes. It is revealed that the latency of the forward erasure recovery scheme is fractionally higher than that of the scheme without erasure control coding or retransmission mechanisms (using UDP), but much lower than that of the adaptive erasure scheme when the packet loss rate is high. Results on comparisons between the two erasure control schemes exhibit their advantages as well as disadvantages in the role of delivering end-to-end services. To show the impact of the bounds derived on the end-to-end performance of a TCP/IP network, a case study is provided to demonstrate how erasure control coding could be used to maximize the performance of practical systems. © 2010 IEEE.