35 resultados para Quality Performance in Our World: What Fast Service Should Really Mean
Resumo:
A hybrid passive-active damping solution with improved system stability margin and enhanced dynamic performance is proposed for high power grid interactive converters. In grid connected active rectifier/inverter application, line side LCL filter improves the high frequency attenuation and makes the converter compatible with the stringent grid power quality regulations. Passive damping though offers a simple and reliable solution but it reduces overall converter efficiency. Active damping solutions do not increase the system losses but can guarantee the stable operation up to a certain speed of dynamic response which is limited by the maximum bandwidth of the current controller. This paper examines this limit and introduces a concept of hybrid passive-active damping solution with improved stability margin and high dynamic performance for line side LCL filter based active rectifier/inverter applications. A detailed design, analysis of the hybrid approach and trade-off between system losses and dynamic performance in grid connected applications are reported. Simulation and experimental results from a 10 kVA prototype demonstrate the effectiveness of the proposed solution. An analytical study on system stability and dynamic response with the variations of various controller and passive filter parameters is presented.
Resumo:
Background: The purpose of this study was to investigate the 12-month outcome of macular edema secondary to both chronic and new central and branch retinal vein occlusions treated with intravitreal bevacizumab in the real-life clinical setting in the UK. Methods: Retrospective case notes analysis of consecutive patients with retinal vein occlusions treated with bevacizumab in 2010 to 2012. Outcome measures were visual acuity (measured with Snellen, converted into logMAR [logarithm of the minimum angle of resolution] for statistical calculation) and central retinal thickness at baseline, 4 weeks post-loading phase, and at 1 year. Results: There were 56 and 100 patients with central and branch retinal vein occlusions, respectively, of whom 62% had chronic edema and received prior therapies and another 32% required additional laser treatments post-baseline bevacizumab. Baseline median visual acuity was 0.78 (interquartile range [IQR] 0.48–1.22) in the central group and 0.6 (IQR 0.3–0.78) in the branch group. In both groups, visual improvement was statistically significant from baseline compared to post-loading (P,0.001 and P=0.03, respectively), but was not significant by month 12 (P=0.058 and P=0.166, respectively); 30% improved by at least three lines and 44% improved by at least one line by month 12. Baseline median central retinal thickness was 449 μm (IQR 388–553) in the central group and 441 µm (IQR 357–501) in the branch group. However, the mean reduction in thickness was statistically significant at post-loading (P,0.001) and at the 12-month time point (P,0.001) for both groups. The average number of injections in 1 year was 4.2 in the central group and 3.3 in the branch group. Conclusion: Our large real-world cohort results indicate that bevacizumab introduced to patients with either new or chronic edema due to retinal vein occlusion can result in resolution of edema and stabilization of vision in the first year.
Resumo:
Productivity measurement poses a challenge for service organizations. Conventional management wisdom holds that this challenge is rooted in the difficulty of accurately quantifying service inputs and outputs. Few service firms have adequate service productivity measurement (SPM) systems in place and implementing such systems may involve organizational transformation. Combining field interviews and literature-based insights, the authors develop a conceptual model of antecedents of SPM in service firms and test it using data from 276 service firms. Results indicate that one out of five antecedents affects the choice to use SPM, namely, the degree of service standardization. In addition, all five hypothesized antecedents and one additional antecedent (perceived appropriateness of the current SPM) predict the degree of SPM usage. In particular, the degree of SPM is positively influenced by the degree of service standardization, service customization, investments in service productivity gains, and the appropriateness of current service productivity measures. In turn, customer integration and the perceived difficulty of measuring service productivity negatively affect SPM. The fact that customer integration impedes actual measurement of service productivity is a surprising finding, given that customer integration is widely seen as a means to increase service productivity. The authors conclude with implications for service organizations and directions for research.
Resumo:
Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.
Resumo:
Purpose: The purpose of this paper is to present the application of logical framework analysis (LFA) for implementing continuous quality improvement (CQI) across multiple settings in a tertiary care hospital. Design/methodology/approach: This study adopts a multiple case study approach. LFA is implemented within three diverse settings, namely, intensive care unit, surgical ward, and acute in-patient psychiatric ward. First, problem trees are developed in order to determine the root causes of quality issues, specific to the three settings. Second, objective trees are formed suggesting solutions to the quality issues. Third, project plan template using logical framework (LOGFRAME) is created for each setting. Findings: This study shows substantial improvement in quality across the three settings. LFA proved to be effective to analyse quality issues and suggest improvement measures objectively. Research limitations/implications: This paper applies LFA in specific, albeit, diverse settings in one hospital. For validation purposes, it would be ideal to analyse in other settings within the same hospital, as well as in several hospitals. It also adopts a bottom-up approach when this can be triangulated with other sources of data. Practical implications: LFA enables top management to obtain an integrated view of performance. It also provides a basis for further quantitative research on quality management through the identification of key performance indicators and facilitates the development of a business case for improvement. Originality/value: LFA is a novel approach for the implementation of CQI programs. Although LFA has been used extensively for project development to source funds from development banks, its application in quality improvement within healthcare projects is scant.