84 resultados para Optometrists


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article reviews those aspects of the biology of fungi which are most relevant to optometrists and considers in more detail, the fungi of particular ocular interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

About 60% of human infections diseases are caused by viruses,including such important diseases as AIDS, polio, rabies and certain forms of cancer. A few groups of viruses are important to optometrists because they either cause a primary eye infection or a systemic viral infection with ocular complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Optometrists are becoming more integrally involved in the diagnosis of and care for glaucoma patients in the UK. The correlation of apparent change in non contact tonometry (NCT) IOP measurement and change in other ocular parameters such as refractive error, corneal curvature, corneal thickness and treatment zone size (data available to optometrists after LASIK) would facilitate care of these patients. Setting: A UK Laser Eye Clinic. Methods: This is a retrospective study study of 200 sequential eyes with myopia with or without astigmatism which underwent LASIK using a Hansatome and an Alcon LADARvision 4000 excimer laser. Refraction keratometry, pachymetry and NCT IOP mesurements were taken before treatmebnt and agian 3 months after treatment. The relationship between these variables anfd teh treatment zones were studied using stepwise multiple regression analysis. Results: There was a mean difference of 5.54mmHg comnparing pre and postoperative NCT IOP. IOP change correlates with refractive error change (P < 0.001), preoperative corneal thickness (P < 0.001) and treatment zone size (P = 0.047). Preoperative corneal thickness correlates with preoperative IOP (P < 0.001) and postoperative IOP (P < 0.001). Using these correlations, the measured difference in NCT IIOP can be predicted preoperatively or postoperatively using derived equations.Conclusion: There is a significant reduction in measured NCT IOP after LASIK. The amount of reduction can be calculated using data acquired by optometrists. This is helpful for opthalmologists and optometrists who co-manage glaucoma patients who have had LASIK or with glaucoma pateints who are consideraing having LASIK.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The concept of sample size and statistical power estimation is now something that Optometrists that want to perform research, whether it be in practice or in an academic institution, cannot simply hide away from. Ethics committees, journal editors and grant awarding bodies are now increasingly requesting that all research be backed up with sample size and statistical power estimation in order to justify any study and its findings. This article presents a step-by-step guide of the process for determining sample sizeand statistical power. It builds on statistical concepts presented in earlier articles in Optometry Today by Richard Armstrong and Frank Eperjesi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There are two aspects of PD of particular interest to optometrists. First, PD patients can develop a range of visual problems including those affecting eye movement, pupillary function, and in complex visual functions involving the ability to judge distance or make out the shape of an object. Second, the symptoms of PD can be treated successfully using a variety of drugs, some of which have significant ocular adverse reactions (OAR). This article describes the general features of PD, the dopamine neurotransmitter system and its relevance to eye symptoms, the visual symptoms reported in PD, and the OAR that have been reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

It has long been sought to measure ocular accommodation continuously in human factor applications such as driving or flying. Open-field autorefractors such as the Canon R-1 could be converted to allow continuous, objective recording, but steady eye fixation and head immobilisation were essential for the measurements to be valid. Image analysis techniques utilised by newer open-view autorefractors such as the Shin-Nippon SRW-5000 are more tolerant to head and eye movements, but perhaps the technique with the greatest potential for the measurement of accommodation in human factor applications is photoretinoscopy. This paper examines the development of techniques for high temporal measurements of accommodation and reports on the tolerance of one such recent commercial instrument, the PowerRefractor (PlusOptiX). The instrument was found to be tolerant to eye movements from the optical axis of the instrument (∼0.50 DS change in apparent accommodation with gaze 25° eccentric to the optical axis), longitudinal head movement (<0.25 DS from 8 cm towards and 20 cm away from the correct photorefractor to eye distance) and changes in background illuminance (<0.25 DS from 0.5 to 20 cd m-2 target luminance). The PowerRefractor also quantifies the direction of gaze and pupil size, but is unable to take measurements with small pupils <3.7 ±1.0 mm. © 2002 The College of Optometrists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Progressive supranuclear palsy is a rare, degenerative brain disorder and the second most common syndrome in which the patient exhibits 'parkinsonism', that is, a variety of symptoms involving problems with movement. General symptoms include difficulties with gait and balance; the patient walking clumsily and often falling backwards. The syndrome can be difficult to diagnose and visual signs and symptoms can help to separate it from closely related movement disorders such as Parkinson's disease, multiple system atrophy, dementia with Lewy bodies and corticobasal degeneration. A combination of the presence of vertical supranuclear gaze palsy, fixation instability, lid retraction, blepharospasm and apraxia of eyelid opening and closing may be useful visual signs in the identification of progressive supranuclear palsy. As primary eye-care practitioners, optometrists should be able to identify the visual problems of patients with this disorder and be expected to work with patients and their carers to manage their visual welfare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis set out to develop an objective analysis programme that correlates with subjective grades but has improved sensitivity and reliability in its measures so that the possibility of early detection and reliable monitoring of changes in anterior ocular surfaces (bulbar hyperaemia, palpebral redness, palpebral roughness and corneal straining) could be increased. The sensitivity of the program was 20x greater than subjective grading by optometrists. The reliability was found to be optimal (r=1.0) with subjective grading up to 144x more variable (r=0.08). Objective measures were used to create formulae for an overall ‘objective-grade’ (per surface) equivalent to those displayed by the CCLRU or Efron scales. The correlation between the formulated objective verses subjective grades was high, with adjusted r2 up to 0.96. Determination of baseline levels of objective grade were investigated over four age groups (5-85years n= 120) so that in practice a comparison against the ‘normal limits’ could be made. Differences for bulbar hyperaemia were found between the age groups (p<0.001), and also for palpebral redness and roughness (p<0.001). The objective formulae were then applied to the investigation of diurnal variation in order to account for any change that may affect the baseline. Increases in bulbar hyperaemia and palpebral redness were found between examinations in the morning and evening. Correlation factors were recommended. The program was then applied to clinical situations in the form of a contact lens trial and an investigation into iritis and keratoconus where it successfully recognised various surface changes. This programme could become a valuable tool, greatly improving the chances of early detection of anterior ocular abnormalities, and facilitating reliable monitoring of disease progression in clinical as well as research environments.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FULL TEXT: Like many people one of my favourite pastimes over the holiday season is to watch the great movies that are offered on the television channels and new releases in the movie theatres or catching up on those DVDs that you have been wanting to watch all year. Recently we had the new ‘Star Wars’ movie, ‘The Force Awakens’, which is reckoned to become the highest grossing movie of all time, and the latest offering from James Bond, ‘Spectre’ (which included, for the car aficionados amongst you, the gorgeous new Aston Martin DB10). It is always amusing to see how vision correction or eye injury is dealt with by movie makers. Spy movies and science fiction movies have a freehand to design aliens with multiples eyes on stalks or retina scanning door locks or goggles that can see through walls. Eye surgery is usually shown in some kind of day case simplified laser treatment that gives instant results, apart from the great scene in the original ‘Terminator’ movie where Arnold Schwarzenegger's android character encounters an injury to one eye and then proceeds to remove the humanoid covering to this mechanical eye over a bathroom sink. I suppose it is much more difficult to try and include contact lenses in such movies. Although you may recall the film ‘Charlie's Angels’, which did have a scene where one of the Angels wore a contact lens that had a retinal image imprinted on it so she could by-pass a retinal scan door lock and an Eddy Murphy spy movie ‘I-Spy’, where he wore contact lenses that had electronic gadgetry that allowed whatever he was looking at to be beamed back to someone else, a kind of remote video camera device. Maybe we aren’t quite there in terms of devices available but these things are probably not the behest of science fiction anymore as the technology does exist to put these things together. The technology to incorporate electronics into contact lenses is being developed and I am sure we will be reporting on it in the near future. In the meantime we can continue to enjoy the unrealistic scenes of eye swapping as in the film ‘Minority Report’ (with Tom Cruise). Much more closely to home, than in a galaxy far far away, in this issue you can find articles on topics much nearer to the closer future. More and more optometrists in the UK are becoming registered for therapeutic work as independent prescribers and the number is likely to rise in the near future. These practitioners will be interested in the review paper by Michael Doughty, who is a member of the CLAE editorial panel (soon to be renamed the Jedi Council!), on prescribing drugs as part of the management of chronic meibomian gland dysfunction. Contact lenses play an active role in myopia control and orthokeratology has been used not only to help provide refractive correction but also in the retardation of myopia. In this issue there are three articles related to this topic. Firstly, an excellent paper looking at the link between higher spherical equivalent refractive errors and the association with slower axial elongation. Secondly, a paper that discusses the effectiveness and safety of overnight orthokeratology with high-permeability lens material. Finally, a paper that looks at the stabilisation of early adult-onset myopia. Whilst we are always eager for new and exciting developments in contact lenses and related instrumentation in this issue of CLAE there is a demonstration of a novel and practical use of a smartphone to assisted anterior segment imaging and suggestions of this may be used in telemedicine. It is not hard to imagine someone taking an image remotely and transmitting that back to a central diagnostic centre with the relevant expertise housed in one place where the information can be interpreted and instruction given back to the remote site. Back to ‘Star Wars’ and you will recall in the film ‘The Phantom Menace’ when Qui-Gon Jinn first meets Anakin Skywalker on Tatooine he takes a sample of his blood and sends a scan of it back to Obi-Wan Kenobi to send for analysis and they find that the boy has the highest midichlorian count ever seen. On behalf of the CLAE Editorial board (or Jedi Council) and the BCLA Council (the Senate of the Republic) we wish for you a great 2016 and ‘may the contact lens force be with you’. Or let me put that another way ‘the CLAE Editorial Board and BCLA Council, on behalf of, a great 2016, we wish for you!’

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: We have adapted the existing , optometry diabetic retinopathy screening pathway and software , so that it can be used for wet AMD fast track referral. Purpose: To compare the conventional, optometry wet AMD fast track referral service using FAX transmission, with a teleophthalmology service using colour fundus photography transmitted to a central retinal grading centre. Method: 40 optometry practices involved in diabetic retinopathy screening were enrolled and had modified computer software installed. Referrals were made by conventional fast track FAX to the macular clinic, and patients were photographed by the optometrist and images transmitted to a central grading centre Results of the two pathways were compared in terms of 1)speed of diagnosis and 2)sensitivity and specificity of diagnosis of wet AMD. Results: Over a ten month period, 62 consecutive patients were referred. The mean time for conventional pathway was 20.8 days (range 3-34),and for new teleophthalmology pathway was 6.9 days (range 1-13). Sensitivity of technician grading of images was 96%, Specificity 53%, and consultant ophthalmologist was sensitivity 96%, specificiity 87%. The technician showed a learning effect with specificity increasing from 30.7% for first 31 patient cohort, to 70.6% for the second cohort. One patient had images that could not be graded. Conclusion: Rapid referral of wet AMD cases by optometrists using modified diabetic retinopathy screening software, allows fast and accurate diagnosis, and may reduce unnecessary referrals. Retinal grading technicians can be trained to grade wet AMD images.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dementia with Lewy bodies ('Lewy body dementia' or 'diffuse Lewy body disease') (DLB) is the second most common form of dementia to affect elderly people, after Alzheimer's disease. A combination of the clinical symptoms of Alzheimer's disease and Parkinson's disease is present in DLB and the disorder is classified as a 'parkinsonian syndrome', a group of diseases which also includes Parkinson's disease, progressive supranuclear palsy, corticobasal degeneration and multiple system atrophy. Characteristics of DLB are fluctuating cognitive ability with pronounced variations in attention and alertness, recurrent visual hallucinations and spontaneous motor features, including akinesia, rigidity and tremor. In addition, DLB patients may exhibit visual signs and symptoms, including defects in eye movement, pupillary function and complex visual functions. Visual symptoms may aid the differential diagnoses of parkinsonian syndromes. Hence, the presence of visual hallucinations supports a diagnosis of Parkinson's disease or DLB rather than progressive supranuclear palsy. DLB and Parkinson's disease may exhibit similar impairments on a variety of saccadic and visual perception tasks (visual discrimination, space-motion and object-form recognition). Nevertheless, deficits in orientation, trail-making and reading the names of colours are often significantly greater in DLB than in Parkinson's disease. As primary eye-care practitioners, optometrists should be able to work with patients with DLB and their carers to manage their visual welfare.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optometrists play an important part in delivering eye care in the United Kingdom; however opportunities for practitioners to extend their role through co-management of patients with ophthalmologists vary across the country. Devolution in Scotland and Wales has led to greater emphasis on community based care in these regions. This thesis reviews the current situation and, by examining ophthalmic outpatient clinic data, discusses further opportunities to reduce demands on secondary care and the cost savings that can be made. To assess whether the profession is currently in a position to adopt an extended clinical role, changes in the availability of optometric instrumentation are assessed over a two year period. An increased prevalence of fundus cameras and contact tonometers places optometrists in a good position to take on further responsibilities in glaucoma management, however future investment could be impacted by the current economic climate as value for money became increasingly important to practitioners looking to purchase equipment. Methods of training optometrists in the necessary skills to utilise new technology to extend their role are evaluated in terms of both learning and cost effectiveness. Interactive distance learning is proposed as a convenient and effective method to deliver continuing professional development. Any changes to optometric practice must take account of the need for a sustainable business and the importance of attracting and retaining patients. The views of patients are assessed through a validated service quality questionnaire, SERVQUAL. The questionnaire is found to be valid for use in an optometry setting. Patients have a generally positive view of the service quality they receive from their optical practice and consider the intangible aspects, in particular responsiveness and empathy, most important. Optometrists are well placed to increase their role in patient management; however a viable business model must exist to enable investment in instrumentation and training.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The principle theme of this thesis is the advancement and expansion of ophthalmic research via the collaboration between professional Engineers and professional Optometrists. The aim has been to develop new and novel approaches and solutions to contemporary problems in the field. The work is sub divided into three areas of investigation; 1) High technology systems, 2) Modification of current systems to increase functionality, and 3) Development of smaller more portable and cost effective systems. High Technology Systems: A novel high speed Optical Coherence Tomography (OCT) system with integrated simultaneous high speed photography was developed achieving better operational speed than is currently available commercially. The mechanical design of the system featured a novel 8 axis alignment system. A full set of capture, analysis, and post processing software was developed providing custom analysis systems for ophthalmic OCT imaging, expanding the current capabilities of the technology. A large clinical trial was undertaken to test the dynamics of contact lens edge interaction with the cornea in-vivo. The interaction between lens edge design, lens base curvature, post insertion times and edge positions was investigated. A novel method for correction of optical distortion when assessing lens indentation was also demonstrated. Modification of Current Systems: A commercial autorefractor, the WAM-5500, was modified with the addition of extra hardware and a custom software and firmware solution to produce a system that was capable of measuring dynamic accommodative response to various stimuli in real time. A novel software package to control the data capture process was developed allowing real time monitoring of data by the practitioner, adding considerable functionality of the instrument further to the standard system. The device was used to assess the accommodative response differences between subjects who had worn UV blocking contact lens for 5 years, verses a control group that had not worn UV blocking lenses. While the standard static measurement of accommodation showed no differences between the two groups, it was determined that the UV blocking group did show better accommodative rise and fall times (faster), thus demonstrating the benefits of the modification of this commercially available instrumentation. Portable and Cost effective Systems: A new instrument was developed to expand the capability of the now defunct Keeler Tearscope. A device was developed that provided a similar capability in allowing observation of the reflected mires from the tear film surface, but with the added advantage of being able to record the observations. The device was tested comparatively with the tearscope and other tear film break-up techniques, demonstrating its potential. In Conclusion: This work has successfully demonstrated the advantages of interdisciplinary research between engineering and ophthalmic research has provided new and novel instrumented solutions as well as having added to the sum of scientific understanding in the ophthalmic field.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim was to investigate the visual effect of coloured filters compared to transmission-matched neutral density filters, in patients with dry age-related macular degeneration. Methods: Visual acuity (VA, logMAR), contrast sensitivity (Pelli-Robson) and colour vision (D15) were recorded for 39 patients (average age 79.1 ± 7.2 years) with age-related macular degeneration, both in the presence and absence of glare from a fluorescent source. Patients then chose their preferred coloured and matched neutral density transmission filters (NoIR). Visual function tests were repeated with the chosen filters, both in the presence and absence of glare from the fluorescent source. Patients trialled the two filters for two weeks each, in random order. Following the trial of each filter, a telephone questionnaire was completed. Results: VA and contrast sensitivity were unaffected by the coloured filters but reduced through the neutral density filters (p < 0.01). VA and contrast sensitivity were reduced by similar amounts, following the introduction of the glare source, both in the presence and absence of filters (p < 0.001). Colour vision error scores were increased following the introduction of a neutral density filter (from 177.6 ± 60.2 to 251.9 ± 115.2) and still further through coloured filters (275.1 ± 50.8; p < 0.001). In the absence of any filter, colour vision error scores increased by 29.1 ± 55.60 units in the presence of glare (F2,107 = 3.9, p = 0.02); however, there was little change in colour vision error scores, in the presence of glare, with either the neutral density or coloured filters. Questionnaires indicated that patients tended to gain more benefit from the coloured filters. Conclusions: Coloured filters had minimal impact on VA and contrast sensitivity in patients with age-related macular degeneration; however, they caused a small reduction in objective colour vision, although this was not registered subjectively by patients. Patients indicated that they received more benefit from the coloured filters compared with neutral density filters. © 2013 The Authors © 2013 Optometrists Association Australia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: The aim was to investigate the effect on the measured amplitude of accommodation and repeatability of using the minus lens technique with the target at distance or near. Methods: Forty-three students (average age: 21.17 ± 1.50 years, 35 female) had their amplitude of accommodation measured with minus lenses on top of their distance correction in a trial frame with the target at far (6.0m) or near (0.4m). The minus lens power was gradually added with steps of 0.25D. Measurements were taken on two occasions at each distance, which were separated by a time interval of at least 24 hours. Results: The measured amplitude at six metres was significantly lower than that with the target at 40cm, by 1.56 ± 1.17D (p < 0.001) and this varied between individuals (r = 0.716, intraclass correlation coefficient = 0.439). With either target distance, repeated measurement was highly correlated (r > 0.9) but the agreement was better at 6.0m (±0.74D) than at 40cm (± 0.92D). Conclusion: The measurements of the amplitude of accommodation with the minus lens technique using targets at far or near are not comparable and the difference between the target distances may provide clinically relevant information. © 2013 Optometrists Association Australia.