218 resultados para Fiber optic sensor


Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a growing interest for esophageal measurements which can provide important and reliable data when diagnosing the motor function of the sphincters and the esophageal body. Biocompatibility, sensing resolution and the comfort of the patient are key parameters for manometric sensing systems. A new sensing approach which could fulfill all these needs is presented in this paper consisting of an embedded polymer fiber sensor, based on multiplexed fiber Bragg gratings. A response to a radial pressure almost 6 times that of a comparable silica fiber based sensor is obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a growing interest for esophageal measurements which can provide important and reliable data when diagnosing the motor function of the sphincters and the esophageal body. Biocompatibility, sensing resolution and the comfort of the patient are key parameters for manometric sensing systems. A new sensing approach which could fulfill all these needs is presented in this paper consisting of an embedded polymer fiber sensor, based on multiplexed fiber Bragg gratings. A response to a radial pressure almost 6 times that of a comparable silica fiber based sensor is obtained.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present what is to our knowledge the first comprehensive investigation of the use of blazed fiber Bragg gratings (BFBGs) to interrogate wavelength division multiplexed (WDM) in-fiber optical sensor arrays. We show that the light outcoupled from the core of these BFBGs is radiated with sufficient optical power that it may be detected with a low-cost charge-coupled device (CCD) array. We present thorough system performance analysis that shows sufficient spectral-spatial resolution to decode sensors with a WDM separation of 75 ρm, signal-to-noise ratio greater than 45-dB bandwidth of 70 nm, and drift of only 0.1 ρm. We show the system to be polarization-state insensitive, making the BFBG-CCD spectral analysis technique a practical, extremely low-cost, alternative to traditional tunable filter approaches.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We propose a simple method for passive nonlinear optical pulse shaping that utilizes pulse prechirping and nonlinear propagation in a normally dispersive nonlinear fiber to generate various temporal waveforms of practical interest from conventional laser pulses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The aim of the research work described in this thesis was to investigate the interrogation of fibre optic sensors using "off the shelf optical components and equipment developed mainly for the telecommunications industry. This provides a cost effective way of bringing fibre optic sensor systems to within the price range of their electro-mechanical counterparts. The research work focuses on the use of an arrayed waveguide grating, an acousto-optic tuneable filter and low-coherence interferometry to measure dynamic strain and displacement using fibre Bragg grating and interferometric sensors. Based on the intrinsic properties of arrayed waveguide gratings and acousto-optic tuneable filters used in conjunction with interferometry, fibre Bragg gratings and interferometric sensors a number of novel fibre optic sensor interrogation systems have been realised. Special single mode fibre, namely, high-birefringence fibre has been employed to implement a dual-beam interrogating interferometer. The first interrogation scheme is based on an optical channel monitor, which is an arrayed waveguide grating with integral photo-detectors providing a number of amplified electrical outputs. It is used to interrogate fibre Bragg grating and interferometric sensors. Using the properties of polarisation maintainability in high-birefringent fibre an interrogating interferometer was realised by winding a length of the fibre around a piezoelectric modulator generating a low-frequency carrier signal. The system was used to interrogate both fibre Bragg grating and interferometric sensors. Finally, the use of an acousto-optic tuneable filter is employed to interrogate fibre Bragg gratings. The device is used to generate a very high frequency carrier signal at the output of an optical interferometer.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have UV-inscribed and theoretically and experimentally analyzed fiber gratings with the structure tilted at 45° and implemented this type of devices as an in-fiber polarizer. A systematic investigation has been carried out on the characterization of 45° tilted fiber gratings (45° TFGs) in terms of the polarization-dependant loss (PDL) and thermal response. The detailed theoretical modeling has revealed a linear correlation between the grating length and the PDL, which has been proved by the experimental results. For the first time, we have examined the UV beam diffraction from a tilted phase mask and designed the UV-inscription system to suit the 45° TFG fabrication. Experimentally, a 24 mm long 45° TFG UV-inscribed in standard telecom single-mode fiber exhibited around 25 dB PDL at 1530 nm and an over ~300 nm bandwidth of PDL spectrum. By the concatenation method, a 44 mm long grating showed a PDL as high as 40 dB that is close to the high polarization extinction ratio of commercial products. Moreover, we have revealed that the PDL of 45° TFGs has low thermal influence, which is desirable for real application devices. Finally, we experimentally demonstrated an all-fiber twist sensor system based on a 45° and an 81° TFG.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report less than 1-dB cross-talk penalty for 26 DWDM channels modulated at 43.7 Gb/s RZ-DPSK when amplified by a fiber optical parametric amplifier showing compatibility with high-capacity (> 1 Tb/s) communication systems. © 2010 Optical Society of America.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pulse generation often requires a stabilized cavity and its corresponding mode structure for initial phase-locking. Contrastingly, modeless cavity-free random lasers provide new possibilities for high quantum efficiency lasing that could potentially be widely tunable spectrally and temporally. Pulse generation in random lasers, however, has remained elusive since the discovery of modeless gain lasing. Here we report coherent pulse generation with modeless random lasers based on the unique polarization selectivity and broadband saturable absorption of monolayer graphene. Simultaneous temporal compression of cavity-free pulses are observed with such a polarization modulation, along with a broadly-tunable pulsewidth across two orders of magnitude down to 900 ps, a broadly-tunable repetition rate across three orders of magnitude up to 3 MHz, and a singly-polarized pulse train at 41 dB extinction ratio, about an order of magnitude larger than conventional pulsed fiber lasers. Moreover, our graphene-based pulse formation also demonstrates robust pulse-to-pulse stability and widewavelength operation due to the cavity-less feature. Such a graphene-based architecture not only provides a tunable pulsed random laser for fiber-optic sensing, speckle-free imaging, and laser-material processing, but also a new way for the non-random CW fiber lasers to generate widely tunable and singly-polarized pulses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fiber Bragg grating sensors recorded in poly(methyl methacrylate) fiber often exhibit hysteresis in the response of Bragg wavelength to strain, particularly when exposed to high levels of strain. We show that, when such a fiber grating sensor is bonded directly to a substrate, the hysteresis is reduced by more than 12 times, compared to the case where the sensor is suspended freely between two supports. © 2013 Optical Society of America.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We report less than 1-dB cross-talk penalty for 26 DWDM channels modulated at 43.7 Gb/s RZ-DPSK when amplified by a fiber optical parametric amplifier showing compatibility with high-capacity (> 1 Tb/s) communication systems. © 2010 Optical Society of America.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We have UV-inscribed and theoretically and experimentally analyzed fiber gratings with the structure tilted at 45° and implemented this type of devices as an in-fiber polarizer. A systematic investigation has been carried out on the characterization of 45° tilted fiber gratings (45° TFGs) in terms of the polarization-dependant loss (PDL) and thermal response. The detailed theoretical modeling has revealed a linear correlation between the grating length and the PDL, which has been proved by the experimental results. For the first time, we have examined the UV beam diffraction from a tilted phase mask and designed the UV-inscription system to suit the 45° TFG fabrication. Experimentally, a 24 mm long 45° TFG UV-inscribed in standard telecom single-mode fiber exhibited around 25 dB PDL at 1530 nm and an over ~300 nm bandwidth of PDL spectrum. By the concatenation method, a 44 mm long grating showed a PDL as high as 40 dB that is close to the high polarization extinction ratio of commercial products. Moreover, we have revealed that the PDL of 45° TFGs has low thermal influence, which is desirable for real application devices. Finally, we experimentally demonstrated an all-fiber twist sensor system based on a 45° and an 81° TFG.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We propose a simple method for passive nonlinear optical pulse shaping that utilizes pulse prechirping and nonlinear propagation in a normally dispersive nonlinear fiber to generate various temporal waveforms of practical interest from conventional laser pulses.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

In non-invasive ventilation, continuous monitoring of respiratory volumes is essential. Here, we present a method for the measurement of respiratory volumes by a single fiber-grating sensor of bending and provide the proof-of-principle by applying a calibration-test measurement procedure on a set of 18 healthy volunteers. Results establish a linear correlation between a change in lung volume and the corresponding change in a local thorax curvature. They also show good sensor accuracy in measurements of tidal and minute respiratory volumes for different types of breathing. The proposed technique does not rely on the air flow through an oronasal mask or the observation of chest movement by a clinician, which distinguishes it from the current clinical practice. © 2014 Optical Society of America.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We present a new class of multi-channel Fiber Bragg grating, which provides the characteristics of channelized dispersion but does so with only a single reflection band. Such gratings can provide pure phase control of optical pulses without introducing any deleterious insertion-loss-variation. © 2006 Optical Society of America.