90 resultados para DOMINANT OPTIC ATROPHY


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There were four principal sections to the work: 1. Investigation of ocular and systemic vascular risk factors in POAG. The principal findings of this work were: a). Glaucoma patients exhibit an anticipatory reaction to the physical stress, similar to subjects at risk for cardiovascular diseases; a blunted BP response and a reduction in ONH blood flow in response to cold provocation was also recorded. b). Silent myocardial ischaemic episodes occurred during peaks in systemic BP and HR. c). Independent of a positive history for cardiovascular diseases, patients suffering from POAG demonstrate a blunt circadian rhythm of the ANS. 2. Assessment of the relationship between vascular and systemic vascular risk factors in GON. The principal findings of this work were: a). POAG patients demonstrate a high sympathetic tonus over a 24-h period. b). POAG patients with lower OBF demonstrate both 24-h systemic BP and HRV abnormalities. c). OBF alterations observed in some glaucoma patients could be either primary or secondary to systemic haemodynamic disturbances and not a consequence of ONH damage. 3. Assessment of the level of systemic anti-oxidant defence in POAG patients. The principal finding of this work was: Patients suffering from POAG demonstrated significantly lower GSH and t-GSH levels than normal controls. 4. Investigation of the effect of treatment with latanoprost 0.005% on visual function and OBF. The findings of this work were: a). Treatment with latanoprost 0.005% resulted in a significant decrease in IOP and increase in OPP. VF damage progression has also been stopped. b). Treatment with latanoprost 0.005% resulted in a significant increase in the OBF parameters measured at the ONH and peripapillary retina levels. Finally, the importance of a clear protocol for managing new POAG cases is highlighted and a clinical conduit is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Loss of optic nerve head (ONH) axons in primary open angle glaucoma (POAG) has been attributed to both mechanical and vascular factors. Confocal scanning laser ophthalmoscopy (cSLO) provides a promising tool for the topographic follow-up of the ONH in glaucoma, while scanning laser Doppler flowmetry (SLDF) facilitates the rapid non-invasive assessment of retinal capillary blood flow. The purposes of these investigations were to optimise the techniques and explore their potential to classify and monitor disease. Preliminary investigations explored the reproducibility and validity of cSLO and SLDF and showed that: For cSLO: In a model eye, measurements are accurate over a range of axial lengths. For best reproducibility, seven images per visit are required, with a contour line located on Elschnig's scleral ring and transferred automatically between images. For SLDF: Three perfusion images are required for optimum reproducibility. Physiological changes induced by gas perturbation can be measured. Cross-sectional comparison of groups of normal subjects and early POAG patients showed that: cSLO parameters differentiate the early POAG group. Blood volume measured by SLDF showed group differences in superior nasal retina only. Longitudinal investigation of ONH topography, haemodynamic and visual field indices in normal subjects and POAG patients showed that: cSLO detects topographical change over time more frequently in the POAG group. Important parameters include: C:D area ratio, cup and rim area, mean depth in contour, volumes above and below reference and surface. Factor analysis identified "cup" and "rim" factors that can be used to detect change over time in individual patients. Blood flow changes were most apparent in the inferior nasal peripapillary retina of the POAG group. Perimetry is of clinical value for the identification of glaucoma but is less sensitive than cSLO for monitoring glaucomatous change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time to the authors' knowledge, fiber Bragg gratings (FBGs) with >80° tilted structures have been fabricated and characterized. Their performance in sensing temperature, strain, and the surrounding medium's refractive index was investigated. In comparison with normal FBGs and long-period gratings (LPGs), >80° tilted FBGs exhibit significantly higher refractive-index responsivity and lower thermal cross sensitivity. When the grating sensor was used to detect changes in refractive index, a responsivity as high as 340nm/refractive-index unit near an index of 1.33 was demonstrated, which is three times higher than that of conventional LPGs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple system atrophy (MSA) is a rare movement disorder and a member of a group of neurodegenerative diseases referred to collectively as the ‘parkinsonian syndromes’. Characteristic of these syndromes is that the patient exhibits symptoms of ‘parkinsonism’, viz., a range of problems involving movement, most typically manifest in Parkinson’s disease (PD) itself1, but also seen in progressive supranuclear palsy (PSP), and to some extent in dementia with Lewy bodies (DLB). MSA is a relatively ‘new’ descriptive term and is derived from three previously described diseases, viz., olivopontocerebellar atrophy, striato-nigral degeneration, and Shy-Drager syndrome. The classical symptoms of MSA include parkinsonism, ataxia, and autonomic dysfunction.6 Ataxia describes a gross lack of coordination of muscle movements while autonomic dysfunction involves a variety of systems that regulate unconscious bodily functions such as heart rate, blood pressure, bladder function, and digestion. Although primarily a neurological disorder, patients with MSA may also develop visual signs and symptoms that could be useful in differential diagnosis. The most important visual signs may include oculomotor dysfunction and problems in pupil reactivity but are less likely to involve aspects of primary vision such as visual acuity, colour vision, and visual fields. In addition, the eye-care practitioner can contribute to the management of the visual problems of MSA and therefore, help to improve quality of life of the patient. Hence, this first article in a two-part series describes the general features of MSA including its prevalence, signs and symptoms, diagnosis, pathology, and possible causes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple system atrophy (MSA) is a rare movement disorder and a member of a group of neurodegenerative diseases, which include Parkinson’s disease (PD) and progressive supranuclear palsy (PSP), and referred to as the ‘parkinsonian syndromes’. Although primarily a neurological disorder, patients with MSA may also develop visual signs and symptoms that could be useful in differential diagnosis. In addition, the eye-care practitioner may contribute to the management of visual problems of MSA patients and therefore, help to improve quality of life. This second article in the series considers the visual signs and symptoms of MSA with special reference to those features most useful in differential diagnosis of the parkinsonian syndromes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The initial aim of this project was to develop a non-contact fibre optic based displacement sensor to operate in the harsh environment of a 'Light Gas Gun' (LGG), which can 'fire' small particles at velocities ranging from 1-8.4 km/s. The LGG is used extensively for research in aerospace to analyze the effects of high speed impacts on materials. Ideally the measurement should be made close to the centre of the impact to minimise corruption of the data from edge effects and survive the impact. A further requirement is that it should operate at a stand-off distance of ~ 8cm. For these reasons we chose to develop a pseudo con-focal intensity sensor, which demonstrated resolution comparable with conventional PVDF sensors combined with high survivability and low cost. A second sensor was developed based on 'Fibre Bragg Gratings' (FBG) which although requiring contact with the target the low weight and very small contact area had minimal effect on the dynamics of the target. The FBG was mounted either on the surface of the target or tangentially between a fixed location. The output signals from the FBG were interrogated in time by a new method. Measurements were made on composite and aluminium plates in the LGG and on low speed drop tests. The particle momentum for the drop tests was chosen to be similar to that of the particles used in the LGG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Atrophy of skeletal muscle in cancer cachexia has been attributed to a tumour-produced highly glycosylated peptide called proteolysis-inducing factor (PIF). The action of PIF is mediated through a high-affinity membrane receptor in muscle. This study investigates the ability of peptides derived from the 20 N-terminal amino acids of the receptor to neutralise PIF action both in vitro and in vivo. Methods: Proteolysis-inducing factor was purified from the MAC16 tumour using an initial pronase digestion, followed by binding on DEAE cellulose, and the pronase was inactivated by heating to 80°C, before purification of the PIF using affinity chromatography. In vitro studies were carried out using C2C12 murine myotubes, while in vivo studies employed mice bearing the cachexia-inducing MAC16 tumour. Results: The process resulted in almost a 23?000-fold purification of PIF, but with a recovery of only 0.004%. Both the D- and L-forms of the 20mer peptide attenuated PIF-induced protein degradation in vitro through the ubiquitin-proteosome proteolytic pathway and increased expression of myosin. In vivo studies showed that neither the D- nor the L-peptides significantly attenuated weight loss, although the D-peptide did show a tendency to increase lean body mass. Conclusion: These results suggest that the peptides may be too hydrophilic to be used as therapeutic agents, but confirm the importance of the receptor in the action of the PIF on muscle protein degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poster section INTRODUCTION. Retrospective Analysis PURPOSE. To evaluate the morphology and location of optic disc haemorrhages (ODH) identified at diabetic retinopathy (DR) screening to establish whether particular ODH are predictive of ocular disease (e.g. glaucoma). METHODS. Retrospective analysis of 77 patients who presented with ODH at DR screening in the Birmingham and Black Country screening programme between June 2009-March 2010. Mean age was 71 years (range 39-89). Cup/disc ratio (CDR), location and morphology of the haemorrhage were recorded. The outcome of the referral and the status of the ODH were followed up a year later. RESULTS. Of the 77 referred, 34 patients were unassessed for possible glaucoma. Of the 43 patients that were assessed in the hospital eye service for glaucoma, 11 (26%) were diagnosed with glaucoma. These glaucoma patients mostly presented with flame haemorrhages (64%) and blot haemorrhages (36%). Haemorrhages tended to adjoin the margin of the OD (64%), and were more commonly flame shaped (64%). They less commonly occurred in the optic disc itself (36%), and were all blot shaped. The OD Cup/disc ratio (CDR) of the patients with glaucoma (n=11) ranged from 0.33-0.57. It is interesting to note the highest CDR was 0.68 in the 77 patients referred. 32 patients were confirmed as not having glaucoma. 24 (75%) of these patients presented with an ODH adjoining the margin, of which 20 (83%) were flame, and 4 blot (17%) shaped. Only 8 (25%) presented with an ODH in the OD, of which 6 (75%) were blot shaped. One year follow up of the 77 referred cases revealed that the ODH resolved in 45 (57%) patients while 10 (13%) still had an ODH present. 15 (21%) were still under ophthalmology hence digital retinal photos were not available for assessment. Six patients (8%) (age range 71-91 years) died within the year, and one lost to follow up. CONCLUSIONS. The results suggest that a significant number of patients with ODH have glaucoma and that the differing morphology of the haemorrhage is not a major predictor i.e. blot versus flame shaped, adjoining or in the optic disc. The cup/disc ratio did not predict glaucoma either.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Free paper session INTRODUCTION. Microaneurysms and haemorrhages within the macula area are a poor predictor of macular oedema as shown by optical coherence tomography (OCT). Our research suggests that it is safe and cost effective to screen patients who present with these surrogate markers annually. PURPOSE. To determine whether microaneurysms (ma) and haemorrhages (hm) within one optic disc diameter of the fovea (ma/hm<1DD) are significant predictors of macular oedema. METHODS. Data were collected over a one-year period from patients attending digital diabetic retinopathy screening. Patients who presented with ma/hm<1DD also had an OCT scan. The fast macula scan on the Stratus OCT was used and an ophthalmologist reviewed the scans to determine whether macular oedema was present. Macular oedema was identified by thickening on the OCT cross-sections. Patients were split into two groups. Group one (325 eyes) included those with best VA?6/9 and group two (30 eyes) with best VA =6/12. Only patients who had no other referable features of diabetic retinopathy were selected. RESULTS. In group one, 6 (1.8%) out of 325 eyes showed thickening on the OCT and were referred to hospital eye service (HES) for further investigation. In group two, 6 (20%) out of 30 eyes showed thickening and were referred to HES. CONCLUSIONS. Ma/hm<1DD become more significant predictors of macular oedema when VA is reduced. Results confirm the grading criteria concerning microaneurysms predicting macular oedema for referable maculopathy in the English national screening programme. OCT is a useful method to accurately identify patients requiring referral to HES.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To study the density and cross-sectional area of axons in the optic nerve in elderly control subjects and in cases of Alzheimer's disease (AD) using an image analysis system. Methods: Sections of optic nerves from control and AD patients were stained with toluidine blue to reveal axon profiles. Results: The density of axons was reduced in both the center and peripheral portions of the optic nerve in AD compared with control patients. Analysis of axons with different cross-sectional areas suggested a specific loss of the smaller sized axons in AD, i.e., those with areas less that 1.99 μm2. An analysis of axons >11 μm2 in cross-sectional area suggested no specific loss of the larger axons in this group of patients. Conclusions: The data suggest that image analysis provides an accurate and reproducible method of quantifying axons in the optic nerve. In addition, the data suggest that axons are lost throughout the optic nerve with a specific loss of the smaller-sized axons. Loss of the smaller axons may explain the deficits in color vision observed in a significant proportion of patients with AD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proteolysis-inducing factor (PIF) induces muscle loss in cancer cachexia through a high affinity membrane bound receptor. This study investigates the mechanism by which the PIF receptor communicates to intracellular signalling pathways. C2C12 murine myoblasts were used as a model using PIF purified from MAC16 tumours. Calcium imaging was determined using fura-4-acetoxymethyl ester (Fura-4-AM). PIF induced a rapid rise in Ca2 +i, which was completely attenuated by a anti-receptor antibody, or peptides representing 20 mers of the N-terminus of the PIF receptor. Other agents catabolic for skeletal muscle including angiotensin II (AngII) tumour necrosis factor-a (TNF-a) and lipopolysaccharide (LPS) also induced a rise in Ca2 +i, but this was not attenuated by anti-PIF-receptor antibody. The rise in Ca2 +i induced by PIF and AngII was completely attenuated by the Zn2 + chelator D-myo-inositol-1,2,6-triphosphate, and this was reversed by administration of exogenous Zn2 +. The Ca2 +i rise induced by PIF was independent of the presence of extracellular Ca2 +, and attenuated by the Ca2 + pump inhibitor thapsigargin, suggesting that the Ca2 +i rise was due to release from intracellular stores. This rise in Ca2 +i induced by PIF was attenuated by both the phospholipase C inhibitor U73122 and 2-APB, an inhibitor of the inositol 1,4,5-triphosphate receptor, suggesting the involvement of a G-protein. Binding of the PIF to its receptor in skeletal muscle triggers a rise in Ca2 +i, which initiates a signalling cascade leading to a depression in protein synthesis, and an increase in protein degradation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibre-optic communications systems have traditionally carried data using binary (on-off) encoding of the light amplitude. However, next-generation systems will use both the amplitude and phase of the optical carrier to achieve higher spectral efficiencies and thus higher overall data capacities(1,2). Although this approach requires highly complex transmitters and receivers, the increased capacity and many further practical benefits that accrue from a full knowledge of the amplitude and phase of the optical field(3) more than outweigh this additional hardware complexity and can greatly simplify optical network design. However, use of the complex optical field gives rise to a new dominant limitation to system performance-nonlinear phase noise(4,5). Developing a device to remove this noise is therefore of great technical importance. Here, we report the development of the first practical ('black-box') all-optical regenerator capable of removing both phase and amplitude noise from binary phase-encoded optical communications signals.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new type of fibre-optic biochemical concentration sensor based on a polymer optical fibre Bragg grating (POFBG) is proposed. The wavelength of the POFBG varies as a function of analyte concentration. The feasibility of this sensing concept is demonstrated by a saline concentration sensor. When polymer fibre is placed in a water based solution the process of osmosis takes place in this water-fibre system. An osmotic pressure which is proportional to the solution concentration, will apply to the fibre in addition to the hydraulic pressure. It tends to drive the water content out of the fibre and into the surrounding solution. When the surrounding solution concentration increases the osmotic pressure increases to drive the water content out of the fibre, consequently increasing the differential hydraulic pressure and reducing the POFBG wavelength. This process will stop once there is a balance between the osmotic pressure and the differential hydraulic pressure. Similarly when the solution concentration decreases the osmotic pressure decreases, leading to a dominant differential hydraulic pressure which drives the water into the fibre till a new pressure balance is established. Therefore the water content in the polymer fibre - and consequently the POFBG wavelength - depends directly on the solution concentration. A POFBG wavelength change of 0.9 nm was measured for saline concentration varying from 0 to 22%. For a wavelength interrogation system with a resolution of 1 pm, a measurement of solution concentration of 0.03% can be expected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

All-optical data processing is expected to play a major role in future optical communications. Nonlinear effects in optical fibers have attractive applications in optical signal processing. In this paper, we review our recent advances in developing all-optical processing techniques at high speed based on optical fiber nonlinearities.