35 resultados para Combined system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We experimentally demonstrated a highly sensitive twist sensor system based on a 45° and an 81° tilted fibre grating (TFG). The 81°-TFG has a set of dual-peaks that are due to the birefringence induced by its extremely tilted structure. When the 81°-TFG subjected to twist, the coupling to the two peaks would interchange from each other, providing a mechanism to measure and monitor the twist. We have investigated the performance of the sensor system by three interrogation methods (spectral, power-measurement and voltage-measurement). The experimental results clearly show that the 81°-TFG and the 45°-TFG could be combined forming a full fibre twist sensor system capable of not just measuring the magnitude but also recognising the direction of the applied twist.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Heavy menstrual bleeding (HMB) is a common problem, yet evidence to inform decisions about initial medical treatment is limited. OBJECTIVES: To assess the clinical effectiveness and cost-effectiveness of the levonorgestrel-releasing intrauterine system (LNG-IUS) (Mirena(®), Bayer) compared with usual medical treatment, with exploration of women's perspectives on treatment. DESIGN: A pragmatic, multicentre randomised trial with an economic evaluation and a longitudinal qualitative study. SETTING: Women who presented in primary care. PARTICIPANTS: A total of 571 women with HMB. A purposeful sample of 27 women who were randomised or ineligible owing to treatment preference participated in semistructured face-to-face interviews around 2 and 12 months after commencing treatment. INTERVENTIONS: LNG-IUS or usual medical treatment (tranexamic acid, mefenamic acid, combined oestrogen-progestogen or progesterone alone). Women could subsequently swap or cease their allocated treatment. OUTCOME MEASURES: The primary outcome was the patient-reported score on the Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period and then again at 5 years. Secondary outcomes included general quality of life (QoL), sexual activity, surgical intervention and safety. Data were analysed using iterative constant comparison. A state transition model-based cost-utility analysis was undertaken alongside the randomised trial. Quality-adjusted life-years (QALYs) were derived from the European Quality of Life-5 Dimensions (EQ-5D) and the Short Form questionnaire-6 Dimensions (SF-6D). The intention-to-treat analyses were reported as cost per QALY gained. Uncertainty was explored by conducting both deterministic and probabilistic sensitivity analyses. RESULTS: The MMAS total scores improved significantly in both groups at all time points, but were significantly greater for the LNG-IUS than for usual treatment [mean difference over 2 years was 13.4 points, 95% confidence interval (CI) 9.9 to 16.9 points; p < 0.001]. However, this difference between groups was reduced and no longer significant by 5 years (mean difference in scores 3.9 points, 95% CI -0.6 to 8.3 points; p = 0.09). By 5 years, only 47% of women had a LNG-IUS in place and 15% were still taking usual medical treatment. Five-year surgery rates were low, at 20%, and were similar, irrespective of initial treatments. There were no significant differences in serious adverse events between groups. Using the EQ-5D, at 2 years, the relative cost-effectiveness of the LNG-IUS compared with usual medical treatment was £1600 per QALY, which by 5 years was reduced to £114 per QALY. Using the SF-6D, usual medical treatment dominates the LNG-IUS. The qualitative findings show that women's experiences and expectations of medical treatments for HMB vary considerably and change over time. Women had high expectations of a prompt effect from medical treatments. CONCLUSIONS: The LNG-IUS, compared with usual medical therapies, resulted in greater improvement over 2 years in women's assessments of the effect of HMB on their daily routine, including work, social and family life, and psychological and physical well-being. At 5 years, the differences were no longer significant. A similar low proportion of women required surgical intervention in both groups. The LNG-IUS is cost-effective in both the short and medium term, using the method generally recommended by the National Institute for Health and Care Excellence. Using the alternative measures to value QoL will have a considerable impact on cost-effectiveness decisions. It will be important to explore the clinical and health-care trajectories of the ECLIPSE (clinical effectiveness and cost-effectiveness of levonorgestrel-releasing intrauterine system in primary care against standard treatment for menorrhagia) trial participants to 10 years, by which time half of the cohort will have reached menopause. TRIAL REGISTRATION: Current Controlled Trials ISRCTN86566246. FUNDING: This project was funded by the NIHR Health Technology Assessment programme and will be published in full in Health Technology Assessment; Vol. 19, No. 88. See the NIHR Journals Library website for further project information.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: Heavy menstrual bleeding (menorrhagia) is a common problem, yet evidence is limited to inform therapeutic decisions.We compared the levonorgestrel-releasing intrauterine system(LNG-IUS) to usual medical treatment in a pragmatic randomised trial in primary care. Methods: We randomly assigned 571 women consulting their primary care providers with menorrhagia to LNG-IUS or to usual medical treatment as clinically appropriate (tranexamic acid, mefenamic acid, combined estrogen/progestogen or progestogen only). The primary outcome was a patient-reported measure ofimpact of menorrhagia, the validated Menorrhagia Multi-Attribute Scale (MMAS), assessed over 2 years. Secondary measures included generic quality of life (SF-36), sexual activity and surgical intervention.Results MMAS scores improved from baseline in both the LNG-IUS and usual medical treatment groups by 6 months (mean increases 32.7 points versus 21.4 points, respectively; P < 0.001for both) and were maintained over 2 years, but improvements were significantly greater with LNG-IUS (mean between-group difference 13.4 points, 95%CI, 9.9–16.9; P < 0.001).All domains of MMAS (practical difficulties, social life, family life,work/daily routine, psychological well being and physical health)improved significantly more with LNG-IUS, as were seven of the eight domains of SF-36. More women were still using LNG-IUSthan usual medical treatment at 2 years (64% versus 38%,P < 0.001). There were no significant between-group differences in surgical intervention rates or sexual activity scores. There were no serious adverse events in either group.Conclusions Among women presenting to primary care providers with menorrhagia, LNG-IUS was more effective than usual medical treatment at reducing the impact of this problem on their quality of life. In practice therefore, conventional treatments, such as tranexamic and mefenamic acid, remain helpful choices in women for whom LNG-IUS is considered unsuitable, or due to individual preference. For other women, LNG-IUS can be confidently recommended as an effective initial medical therapy for menorrhagia. Funding: This project was funded by the National Institute for Health Research Health Technology Assessment (NIHR HTA) Programme (project number 02/06/02)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this study, two linear coplanar array antennas based on Indium Phosphide (InP) substrate are designed, presented and compared in terms of bandwidth and gain. Slot introduction in combination with coplanar structure is investigated, providing enhanced antenna gain and bandwidth at the 60 GHz frequency band. In addition the proposed array antennas are evaluated in terms of integration with a high-speed photodiode and investigated in terms of matching, providing a bandwidth that reaches 2 GHz. Moreover a potential beam forming scenario combined with photonic up-conversion scheme has been proposed. © 2013 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose – The purpose of this paper is to develop an integrated patient-focused analytical framework to improve quality of care in accident and emergency (A&E) unit of a Maltese hospital. Design/methodology/approach – The study adopts a case study approach. First, a thorough literature review has been undertaken to study the various methods of healthcare quality management. Second, a healthcare quality management framework is developed using combined quality function deployment (QFD) and logical framework approach (LFA). Third, the proposed framework is applied to a Maltese hospital to demonstrate its effectiveness. The proposed framework has six steps, commencing with identifying patients’ requirements and concluding with implementing improvement projects. All the steps have been undertaken with the involvement of the concerned stakeholders in the A&E unit of the hospital. Findings – The major and related problems being faced by the hospital under study were overcrowding at A&E and shortage of beds, respectively. The combined framework ensures better A&E services and patient flow. QFD identifies and analyses the issues and challenges of A&E and LFA helps develop project plans for healthcare quality improvement. The important outcomes of implementing the proposed quality improvement programme are fewer hospital admissions, faster patient flow, expert triage and shorter waiting times at the A&E unit. Increased emergency consultant cover and faster first significant medical encounter were required to start addressing the problems effectively. Overall, the combined QFD and LFA method is effective to address quality of care in A&E unit. Practical/implications – The proposed framework can be easily integrated within any healthcare unit, as well as within entire healthcare systems, due to its flexible and user-friendly approach. It could be part of Six Sigma and other quality initiatives. Originality/value – Although QFD has been extensively deployed in healthcare setup to improve quality of care, very little has been researched on combining QFD and LFA in order to identify issues, prioritise them, derive improvement measures and implement improvement projects. Additionally, there is no research on QFD application in A&E. This paper bridges these gaps. Moreover, very little has been written on the Maltese health care system. Therefore, this study contributes demonstration of quality of emergency care in Malta.