39 resultados para visual loss


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma activity to stationary grating stimuli was studied non-invasively using MEG recordings in humans. Using a spatial filtering technique, we localized gamma activity to primary visual cortex. We tested the hypothesis that spatial frequency properties of visual stimuli may be related to the temporal frequency characteristics of the associated cortical responses. We devised a method to assess temporal frequency differences between stimulus-related responses that typically exhibit complex spectral shapes. We applied this methodology to either single-trial (induced) or time-averaged (evoked) responses in four frequency ranges (0-40, 20-60, 40-80 and 60-100 Hz) and two time windows (either the entire duration of stimulus presentation or the first second following stimulus onset). Our results suggest that stimuli of varying spatial frequency induce responses that exhibit significantly different temporal frequency characteristics. These effects were particularly accentuated for induced responses in the classical gamma frequency band (20-60 Hz) analyzed over the entire duration of stimulus presentation. Strikingly, examining the first second of the responses following stimulus onset resulted in significant loss in stimulus specificity, suggesting that late signal components contain functionally relevant information. These findings advocate a functional role of gamma activity in sensory representation. We suggest that stimulus specific frequency characteristics of MEG signals can be mapped to processes of neuronal synchronization within the framework of coupled dynamical systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alzheimer's disease is the commonest degenerative disease of the nervous system to affect elderly people. It is characterised by 'dementia', a global cognitive decline involving loss of short term memory, judgement and emotional control. In addition, patients may suffer a range of visual problems including impairment of visual acuity, colour vision, eye movement problems and complex visual disturbances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The thesis investigated progression of the central 10° visual field with structural changes at the macula in a cross-section of patients with varying degrees of agerelated macular degeneration (AMD). The relationships between structure and function were investigated for both standard and short-wavelength automated perimetry (SWAP). Factors known to influence the measure of visual field progression were considered, including the accuracy of the refractive correction on SWAP thresholds and the learning effect. Techniques of assessing the structure to function relationships between fundus images and the visual field were developed with computer programming and evaluated for repeatability. Drusen quantification of fundus photographs and retro-mode scanning laser ophthalmoscopic images was performed. Visual field progression was related to structural changes derived from both manual and automated methods. Principal Findings: • Visual field sensitivity declined with advancing stage of AMD. SWAP showed greater sensitivity to progressive changes than standard perimetry. • Defects were confined to the central 5°. SWAP defects occurred at similar locations but were deeper and wider than corresponding standard perimetry defects. • The central field became less uniform as severity of AMD increased. SWAP visual field indices of focal loss were of more importance when detecting early change in AMD, than indices of diffuse loss. • The decline in visual field sensitivity over stage of severity of AMD was not uniform, whereas a linear relationship was found between the automated measure of drusen area and visual field parameters. • Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. • Overcorrection of the refraction for the working distance in SWAP should be avoided in subjects with insufficient accommodative facility. • The perimetric learning effect in the 10° field did not differ significantly between normal subjects and AMD patients. • Subretinal deposits appeared more numerous in retro-mode imaging than in fundus photography.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We sought to determine the extent to which red–green, colour–opponent mechanisms in the human visual system play a role in the perception of drifting luminance–modulated targets. Contrast sensitivity for the directional discrimination of drifting luminance–modulated (yellow–black) test sinusoids was measured following adaptation to isoluminant red–green sinusoids drifting in either the same or opposite direction. When the test and adapt stimuli drifted in the same direction, large sensitivity losses were evident at all test temporal frequencies employed (1–16 Hz). The magnitude of the loss was independent of temporal frequency. When adapt and test stimuli drifted in opposing directions, large sensitivity losses were evident at lower temporal frequencies (1–4 Hz) and declined with increasing temporal frequency. Control studies showed that this temporal–frequency–dependent effect could not reflect the activity of achromatic units. Our results provide evidence that chromatic mechanisms contribute to the perception of luminance–modulated motion targets drifting at speeds of up to at least 32°s-1. We argue that such mechanisms most probably lie within a parvocellular–dominated cortical visual pathway, sensitive to both chromatic and luminance modulation, but only weakly selective for the direction of stimulus motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The binocular Esterman visual field test (EVFT) is the current visual field test for driving in the UK. Merging of monocular field tests (Integrated Visual Field, IVF) has been proposed as an alternative for glaucoma patients. Aims: To examine the level of agreement between the EVFT and IVF for patients with binocular paracentral scotomata, caused by either ophthalmological or neurological conditions, and to compare outcomes with useful field of view (UFOV) performance, a test of visual attention thought to be important in driving. Methods: 60 patients with binocular paracentral scotomata but normal visual acuity (VA) were recruited prospectively. Subjects completed and were classified as “pass” or “fail” for the EVFT, IVF and UFOV. Results: Good agreement occurred between the EVFT and IVF in classifying subjects as “pass” or “fail” (kappa?=?0.84). Classifications disagreed for four subjects with paracentral scotomata of neurological origin (three “passed” IVF yet “failed” EVFT). Mean UFOV scores did not differ between those who “passed” and those who “failed” both visual field tests (p?=?0.11). Agreement between the visual field tests and UFOV was limited (EVFT kappa?=?0.22, IVF kappa 0.32). Conclusions: Although the IVF and EVFT agree well in classifying visual fields with regard to legal fitness to drive in the UK, the IVF “passes” some individuals currently classed as unfit to drive due to paracentral scotomata of non-glaucomatous origin. The suitability of the UFOV for assessing crash risk in those with visual field loss is questionable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis considers the visual electrophysiological effects of vigabatrin (an anti-epileptic drug, which acts by increasing the levels of the inhibitory neurotransmitter GABA on the retina of the eye compared to the concentric visual field defects which have been found associated with the drug. Flash and pattern ERG's, EOG's multifocal ERG's (VERIS), flash and pattern VEP's and visual fields were tested. Although VEP's have been shown not to be affected by vigabatrin, these were recorded to complete the testing. Initially, of the eight vigabatrin patients with known visual field defects, 7 showed abnormally delayed 30Hz flicker a-wave latencies, 5 abnormally delayed 30Hz b-wave latencies and 6 abnormally low 30Hz amplitudes. Also 7 showed an abnormally prolonged latency of oscillatory potential 1 (OP1). The two patients taking vigabatrin at the time of testing showed low EOG Arden index values. The VERIS results correlated well with the severity of the visual field defects. Following this finding, eleven healthy subjects received vigabatrin over a 10-day period. No changes were seen in the visual fields, however, the photopic ERG b-wave latency significantly increased (although not to abnormal values). A matched pairs study with eleven vigabatrin, patients and eleven epileptic patients, who had never taken vigabatrin supported the findings of abnormal 30Hz flicker b-wave and OP latencies associated with vigabatrin, again with the VERIS results correlating to the severity of the visual field defect. The abnormal 30Hz flicker and VERIS responses indicate involvement of the cone photoreceptors and the OP's show an effect on the amacrine cells. The ERG increase in the photopic b-wave latency also suggests involvement of the bipolar cells, however, this effect and the reversible effect on the Arden index after cessation of the drug may be unrelated to the visual field defect. To conclude this thesis, a field specific VEP stimulus was developed to assess the retinal function in the peripheral field of paediatric patients. It comprises of a dartboard stimulus with a central 0-5 degree black and white chequered stimulus, a blank 5-30 degree annulus and a 30-60 degree peripheral chequered stimulus. When optimised on four vigabatrin patients it was found that no peripheral response can be evoked with a field loss exceeding 30-35 degrees. Co-operation was found to be successful in children as young as four years old.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study developed statistical techniques to evaluate visual field progression for use with the Humphrey Field Analyzer (HFA). The long-term fluctuation (LF) was evaluated in stable glaucoma. The magnitude of both LF components showed little relationship with MD, CPSD and SF. An algorithm was proposed for determining the clinical necessity for a confirmatory follow-up examination. The between-examination variability was determined for the HFA Standard and FASTPAC algorithms in glaucoma. FASTPAC exhibited greater between-examination variability than the Standard algorithm across the range of sensitivities and with increasing eccentricity. The difference in variability between the algorithms had minimal clinical significance. The effect of repositioning the baseline in the Glaucoma Change Probability Analysis (GCPA) was evaluated. The global baseline of the GCPA limited the detection of progressive change at a single stimulus location. A new technique, pointwise univariate linear regressions (ULR), of absolute sensitivity and, of pattern deviation, against time to follow-up was developed. In each case, pointwise ULR was more sensitive to localised progressive changes in sensitivity than ULR of MD, alone. Small changes in sensitivity were more readily determined by the pointwise ULR than by the GCPA. A comparison between the outcome of pointwise ULR for all fields and for the last six fields manifested linear and curvilinear declines in the absolute sensitivity and the pattern deviation. A method for delineating progressive loss in glaucoma, based upon the error in the forecasted sensitivity of a multivariate model, was developed. Multivariate forecasting exhibited little agreement with GCPA in glaucoma but showed promise for monitoring visual field progression in OHT patients. The recovery of sensitivity in optic neuritis over time was modelled with a Cumulative Gaussian function. The rate and level of recovery was greater in the peripheral than the central field. Probability models to forecast the field of recovery were proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study investigated the detrimental effect of central field loss (CFL) on reading ability and general visual function. The aim was to improve the understanding of reading with eccentric retina in order that reading performances of individuals with CFL may be maximised. To improve visual ability of individuals with CFL, it is important to be able to accurately measure the outcome of any intervention. Various methods for determining visual function were therefore compared with perceived visual performance (as measured with a quality of life questionnaire) before and after surgical removal of choroidal new vessels (CNV) in macular disease patients. The results highlight the importance of low contrast measures (low contrast visual acuity and contrast sensitivity) when investigating perceived reading performance. Reading speed was found to be important for reflecting changes in general visual quality of life. Potential causes for reduced peripheral reading ability were investigated using both normally sighted and CFL subjects. For normally sighted subjects reading eccentrically with rapid serial visual presentation (RSVP) text, the inferior visual field was a better position (in terms of reading speed) for the presentation of the text. The size of the visual span was found to reduce with increasing eccentricity of fixation, providing a potential reason for reduced peripheral reading performances. The investigation of the ability to use context when reading with peripheral retina resulted in conflicting results. Studies in this thesis found both a reduction and no reduction in the ability of the peripheral retina to utilise context compared to the fovea. Individuals with long-term CFL showed no improvement in peripheral reading ability over that found for normally sighted subjects reading at the same eccentricity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Octopus Automated Perimeter was validated in a comparative study and found to offer many advantages in the assessment of the visual field. The visual evoked potential was investigated in an extensive study using a variety of stimulus parameters to simulate hemianopia and central visual field defects. The scalp topography was recorded topographically and a technique to compute the source derivation of the scalp potential was developed. This enabled clarification of the expected scalp distribution to half field stimulation using different electrode montages. The visual evoked potential following full field stimulation was found to be asymmetrical around the midline with a bias over the left occiput particularly when the foveal polar projections of the occipital cortex were preferentially stimulated. The half field response reflected the distribution asymmetry. Masking of the central 3° resulted in a response which was approximately symmetrical around the midline but there was no evidence of the PNP-complex. A method for visual field quantification was developed based on the neural representation of visual space (Drasdo and Peaston 1982) in an attempt to relate visual field depravation with the resultant visual evoked potentials. There was no form of simple, diffuse summation between the scalp potential and the cortical generators. It was, however, possible to quantify the degree of scalp potential attenuation for M-scaled full field stimuli. The results obtained from patients exhibiting pre-chiasmal lesions suggested that the PNP-complex is not scotomatous in nature but confirmed that it is most likely to be related to specific diseases (Harding and Crews 1982). There was a strong correlation between the percentage information loss of the visual field and the diagnostic value of the visual evoked potential in patients exhibiting chiasmal lesions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Vigabatrin (VGB) is a transaminase inhibitor that elicits its anitepileptic effect by increasing GABA concentrations in the brain and retina. - Assess whether certain factors predispose patients to develop severe visual field loss. - Develop a sensitive algorithm for investigating the progression of visual field loss. - Determine the most sensitive clinical regimen for diagnosing VGB-attributed visual field loss. - Investigate whether the reports of central retinal sparing are accurate. The investigations have resulted in a number of significant findings: - The anatomical evidence in combination with the pattern of visual field loss suggests that the damage induced by VGB therapy occurs at retinal level, and is most likely a toxic effect. - The quantitative algorithm, designed within the course of this investigation, provided increased sensitivity in determining the severity of visual field loss. - Maximum VGB dose predisposes patients to develop severe visual field loss. - The SITA Standard algorithm was found to be as sensitive and significantly faster, in diagnosing visual field defects attributed to VGB, when compared to the Full Threshold algorithm. The Full Threshold was found to be the most repeatable between visits. - The normal SWAP 10-2 database provided an effective method of differentiating SWAP defects. - SWAP, FDT and the mfERG have increased sensitivity in detecting visual field loss attributed to VGB. The pattern of visual field loss from these investigations suggests that VGB produces a diffuse effect across the retina including subtle central abnormalities and more severe peripheral defects. - Abnormalities detected using the mfERG have suggested that VGB adversely affects the photoreceptors Müller, amacrine and ganglion cells in the retina. An urgent review of the manufacturers recommended maximum dose for VGB is required.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parkinson’s disease (PD) is a common disorder of middle-aged and elderly people in which degeneration of the extrapyramidal motor system causes significant movement problems. In some patients, however, there are additional disturbances in sensory systems including loss of the sense of smell and auditory and/or visual problems. This article is a general overview of the visual problems likely to be encountered in PD. Changes in vision in PD may result from alterations in visual acuity, contrast sensitivity, colour discrimination, pupil reactivity, eye movements, motion perception, visual field sensitivity and visual processing speeds. Slower visual processing speeds can also lead to a decline in visual perception especially for rapidly changing visual stimuli. In addition, there may be disturbances of visuo-spatial orientation, facial recognition problems, and chronic visual hallucinations. Some of the treatments used in PD may also have adverse ocular reactions. The pattern electroretinogram (PERG) is useful in evaluating retinal dopamine mechanisms and in monitoring dopamine therapies in PD. If visual problems are present, they can have an important effect on the quality of life of the patient, which can be improved by accurate diagnosis and where possible, correction of such defects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Alzheimer’s disease (AD) is an important neurodegenerative disorder causing visual problems in the elderly population. The pathology of AD includes the deposition in the brain of abnormal aggregates of ?-amyloid (A?) in the form of senile plaques (SP) and abnormally phosphorylated tau in the form of neurofibrillary tangles (NFT). A variety of visual problems have been reported in patients with AD including loss of visual acuity (VA), colour vision and visual fields; changes in pupillary responses to mydriatics, defects in fixation and in smooth and saccadic eye movements; changes in contrast sensitivity and in visual evoked potentials (VEP); and disturbances in complex visual tasks such as reading, visuospatial function, and in the naming and identification of objects. In addition, pathological changes have been observed to affect the eye, visual pathway, and visual cortex in AD. To better understand degeneration of the visual cortex in AD, the laminar distribution of the SP and NFT was studied in visual areas V1 and V2 in 18 cases of AD which varied in disease onset and duration. In area V1, the mean density of SP and NFT reached a maximum in lamina III and in laminae II and III respectively. In V2, mean SP density was maximal in laminae III and IV and NFT density in laminae II and III. The densities of SP in laminae I of V1 and NFT in lamina IV of V2 were negatively correlated with patient age. No significant correlations were observed in any cortical lamina between the density of NFT and disease onset or duration. However, in area V2, the densities of SP in lamina II and lamina V were negatively correlated with disease duration and disease onset respectively. In addition, there were several positive correlations between the densities of SP and NFT in V1 with those in area V2. The data suggest: (1) NFT pathology is greater in area V2 than V1, (2) laminae II/III of V1 and V2 are most affected by the pathology, (3) the formation of SP and NFT in V1 and V2 are interconnected, and (4) the pathology may spread between visual areas via the feed-forward short cortico-cortical connections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presentation Purpose:To relate structural change to functional change in age-related macular degeneration (AMD) in a cross-sectional population using fundus imaging and the visual field status. Methods:10 degree standard and SWAP visual fields and other standard functional clinical measures were acquired in 44 eyes of 27 patients at various stages of AMD, as well as fundus photographs. Retro-mode SLO images were captured in a subset of 29 eyes of 19 of the patients. Drusen area, measured by automated drusen segmentation software (Smith et al. 2005) was correlated with visual field data. Visual field defect position was compared to the position of the imaged drusen and deposits using custom software. Results:The effect of AMD stage on drusen area within the 6000µm was significant (One-way ANOVA: F = 17.231, p < 0.001), however the trend was not strong across all stages. There were significant linear relationships between visual field parameters and drusen area. The mean deviation (MD) declined by 3.00dB and 3.92dB for each log % drusen area for standard perimetry and SWAP, respectively. The visual field parameters of focal loss displayed the strongest correlations with drusen area. The number of pattern deviation (PD) defects increased by 9.30 and 9.68 defects per log % drusen area for standard perimetry and SWAP, respectively. Weaker correlations were found between drusen area and visual acuity, contrast sensitivity, colour vision and reading speed. 72.6% of standard PD defects and 65.2% of SWAP PD defects coincided with retinal signs of AMD on fundus photography. 67.5% of standard PD defects and 69.7% of SWAP PD defects coincided with deposits on retro-mode images. Conclusions:Perimetry exhibited a stronger relationship with drusen area than other measures of visual function. The structure-function relationship between visual field parameters and drusen area was linear. Overall the indices of focal loss had a stronger correlation with drusen area in SWAP than in standard perimetry. Visual field defects had a high coincidence proportion with retinal manifestations of AMD.Smith R.T. et al. (2005) Arch Ophthalmol 123:200-206.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Presentation Purpose:To examine the correlation of central visual field loss and progression of structural changes in the macular area in age-related macular degeneration (AMD). Methods:Central 10° standard and short-wavelength automated perimetry (SWAP) visual fields were acquired in 39 eyes of 24 patients with AMD using a Humphrey Field Analyzer. Stereoscopic fundus photographs were graded1 by two independent observers and the stage of disease determined2. Custom software mapped perimetric data onto fundus images in order to relate structural changes to functional loss. Results:Mean deviation (MD) in standard perimetry changed from 0.04 dB at stage 1 to -12.39 dB at stage 4 (r2=0.48, p<0.001). The group mean SWAP MD was -5.26 dB at stage 1 and increased to -17.08 dB at stage 4 (r2=0.53, p<0.001). Pattern standard deviation (PSD) also increased with advancing stage in standard perimetry; 1.32 dB to 8.67 dB at stage 1 and 4, respectively (r2=0.54, p<0.001). In SWAP, PSD increased from 2.86 dB to 5.63 dB at stage 1 and stage 4 (r2=0.43, p<0.001). Defect frequency was greater in SWAP than standard perimetry. Early stage defects occurred with the greatest frequency at eccentricities of 3.2° and 5.1° in standard perimetry and at 4.2° in SWAP. Late stage defects were most frequent at 1° eccentricity in standard perimetry and at 1° and 9° in SWAP. MD declined with increasing affected retinal area over the central 3000µm; by 0.20 dB (r2=0.67, p<0.001) and 0.18 dB (r2=0.49, p<0.001) per % increase in defect area for standard perimetry and SWAP respectively. 41% of defects were associated with structural changes on the retina in standard perimetry and 43% in SWAP. Conclusions:Sensitivity decreased with advancing stage of AMD, with a greater effect demonstrated in SWAP compared to standard perimetry. The central field became less uniform as stage increased. SWAP defects occurred at similar locations but were deeper and wider than corresponding defects in standard perimetry. Central loss in SWAP is a sensitive marker of functional progression in AMD.1. Bird et al. (1995) Surv Ophthalmol 39:367-3742. van Leeuwen et al. (2003) Arch Ophthalmol 121:519-526

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visual field assessment is a core component of glaucoma diagnosis and monitoring, and the Standard Automated Perimetry (SAP) test is considered up until this moment, the gold standard of visual field assessment. Although SAP is a subjective assessment and has many pitfalls, it is being constantly used in the diagnosis of visual field loss in glaucoma. Multifocal visual evoked potential (mfVEP) is a newly introduced method used for visual field assessment objectively. Several analysis protocols have been tested to identify early visual field losses in glaucoma patients using the mfVEP technique, some were successful in detection of field defects, which were comparable to the standard SAP visual field assessment, and others were not very informative and needed more adjustment and research work. In this study, we implemented a novel analysis approach and evaluated its validity and whether it could be used effectively for early detection of visual field defects in glaucoma. OBJECTIVES: The purpose of this study is to examine the effectiveness of a new analysis method in the Multi-Focal Visual Evoked Potential (mfVEP) when it is used for the objective assessment of the visual field in glaucoma patients, compared to the gold standard technique. METHODS: 3 groups were tested in this study; normal controls (38 eyes), glaucoma patients (36 eyes) and glaucoma suspect patients (38 eyes). All subjects had a two standard Humphrey visual field HFA test 24-2 and a single mfVEP test undertaken in one session. Analysis of the mfVEP results was done using the new analysis protocol; the Hemifield Sector Analysis HSA protocol. Analysis of the HFA was done using the standard grading system. RESULTS: Analysis of mfVEP results showed that there was a statistically significant difference between the 3 groups in the mean signal to noise ratio SNR (ANOVA p<0.001 with a 95% CI). The difference between superior and inferior hemispheres in all subjects were all statistically significant in the glaucoma patient group 11/11 sectors (t-test p<0.001), partially significant 5/11 (t-test p<0.01) and no statistical difference between most sectors in normal group (only 1/11 was significant) (t-test p<0.9). sensitivity and specificity of the HAS protocol in detecting glaucoma was 97% and 86% respectively, while for glaucoma suspect were 89% and 79%. DISCUSSION: The results showed that the new analysis protocol was able to confirm already existing field defects detected by standard HFA, was able to differentiate between the 3 study groups with a clear distinction between normal and patients with suspected glaucoma; however the distinction between normal and glaucoma patients was especially clear and significant. CONCLUSION: The new HSA protocol used in the mfVEP testing can be used to detect glaucomatous visual field defects in both glaucoma and glaucoma suspect patient. Using this protocol can provide information about focal visual field differences across the horizontal midline, which can be utilized to differentiate between glaucoma and normal subjects. Sensitivity and specificity of the mfVEP test showed very promising results and correlated with other anatomical changes in glaucoma field loss.