27 resultados para night vision system
Resumo:
The processing conducted by the visual system requires the combination of signals that are detected at different locations in the visual field. The processes by which these signals are combined are explored here using psychophysical experiments and computer modelling. Most of the work presented in this thesis is concerned with the summation of contrast over space at detection threshold. Previous investigations of this sort have been confounded by the inhomogeneity in contrast sensitivity across the visual field. Experiments performed in this thesis find that the decline in log contrast sensitivity with eccentricity is bilinear, with an initial steep fall-off followed by a shallower decline. This decline is scale-invariant for spatial frequencies of 0.7 to 4 c/deg. A detailed map of the inhomogeneity is developed, and applied to area summation experiments both by incorporating it into models of the visual system and by using it to compensate stimuli in order to factor out the effects of the inhomogeneity. The results of these area summation experiments show that the summation of contrast over area is spatially extensive (occurring over 33 stimulus carrier cycles), and that summation behaviour is the same in the fovea, parafovea, and periphery. Summation occurs according to a fourth-root summation rule, consistent with a “noisy energy” model. This work is extended to investigate the visual deficit in amblyopia, finding that area summation is normal in amblyopic observers. Finally, the methods used to study the summation of threshold contrast over area are adapted to investigate the integration of coherent orientation signals in a texture. The results of this study are described by a two-stage model, with a mandatory local combination stage followed by flexible global pooling of these local outputs. In each study, the results suggest a more extensive combination of signals in vision than has been previously understood.
Resumo:
Golfers, coaches and researchers alike, have all keyed in on golf putting as an important aspect of overall golf performance. Of the three principle putting tasks (green reading, alignment and the putting action phase), the putting action phase has attracted the most attention from coaches, players and researchers alike. This phase includes the alignment of the club with the ball, the swing, and ball contact. A significant amount of research in this area has focused on measuring golfer’s vision strategies with eye tracking equipment. Unfortunately this research suffers from a number of shortcomings, which limit its usefulness. The purpose of this thesis was to address some of these shortcomings. The primary objective of this thesis was to re-evaluate golfer’s putting vision strategies using binocular eye tracking equipment and to define a new, optimal putting vision strategy which was associated with both higher skill and success. In order to facilitate this research, bespoke computer software was developed and validated, and new gaze behaviour criteria were defined. Additionally, the effects of training (habitual) and competition conditions on the putting vision strategy were examined, as was the effect of ocular dominance. Finally, methods for improving golfer’s binocular vision strategies are discussed, and a clinical plan for the optometric management of the golfer’s vision is presented. The clinical management plan includes the correction of fundamental aspects of golfers’ vision, including monocular refractive errors and binocular vision defects, as well as enhancement of their putting vision strategy, with the overall aim of improving performance on the golf course. This research has been undertaken in order to gain a better understanding of the human visual system and how it relates to the sport performance of golfers specifically. Ultimately, the analysis techniques and methods developed are applicable to the assessment of visual performance in all sports.
Resumo:
In this paper we propose an approach based on self-interested autonomous cameras, which exchange responsibility for tracking objects in a market mechanism, in order to maximise their own utility. A novel ant-colony inspired mechanism is used to grow the vision graph during runtime, which may then be used to optimise communication between cameras. The key benefits of our completely decentralised approach are on the one hand generating the vision graph online which permits the addition and removal cameras to the network during runtime and on the other hand relying only on local information, increasing the robustness of the system. Since our market-based approach does not rely on a priori topology information, the need for any multi-camera calibration can be avoided. © 2011 IEEE.
Resumo:
The semantic web vision is one in which rich, ontology-based semantic markup will become widely available. The availability of semantic markup on the web opens the way to novel, sophisticated forms of question answering. AquaLog is a portable question-answering system which takes queries expressed in natural language and an ontology as input, and returns answers drawn from one or more knowledge bases (KBs). We say that AquaLog is portable because the configuration time required to customize the system for a particular ontology is negligible. AquaLog presents an elegant solution in which different strategies are combined together in a novel way. It makes use of the GATE NLP platform, string metric algorithms, WordNet and a novel ontology-based relation similarity service to make sense of user queries with respect to the target KB. Moreover it also includes a learning component, which ensures that the performance of the system improves over the time, in response to the particular community jargon used by end users.
Resumo:
The semantic web (SW) vision is one in which rich, ontology-based semantic markup will become widely available. The availability of semantic markup on the web opens the way to novel, sophisticated forms of question answering. AquaLog is a portable question-answering system which takes queries expressed in natural language (NL) and an ontology as input, and returns answers drawn from one or more knowledge bases (KB). AquaLog presents an elegant solution in which different strategies are combined together in a novel way. AquaLog novel ontology-based relation similarity service makes sense of user queries.
Resumo:
Magnification can be provided to assist those with visual impairment to make the best use of remaining vision. Electronic transverse magnification of an object was first conceived for use in low vision in the late 1950s, but has developed slowly and is not extensively prescribed because of its relatively high cost and lack of portability. Electronic devices providing transverse magnification have been termed closed-circuit televisions (CCTVs) because of the direct cable link between the camera imaging system and monitor viewing system, but this description generally refers to surveillance devices and does not indicate the provision of features such as magnification and contrast enhancement. Therefore, the term Electronic Vision Enhancement Systems (EVES) is proposed to better distinguish and describe such devices. This paper reviews current knowledge on EVES for the visually impaired in terms of: classification; hardware and software (development of technology, magnification and field-of-view, contrast and image enhancement); user aspects (users and usage, reading speed and duration, and training); and potential future development of EVES. © 2003 The College of Optometrists.
Resumo:
Multiple system atrophy (MSA) is a rare movement disorder and a member of the 'parkinsonian syndromes', which also include Parkinson's disease (PD), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB) and corticobasal degeneration (CBD). Multiple system atrophy is a complex syndrome, in which patients exhibit a variety of signs and symptoms, including parkinsonism, ataxia and autonomic dysfunction. It can be difficult to separate MSA from the other parkinsonian syndromes but if ocular signs and symptoms are present, they may aid differential diagnosis. Typical ocular features of MSA include blepharospasm, excessive square-wave jerks, mild to moderate hypometria of saccades, impaired vestibular-ocular reflex (VOR), nystagmus and impaired event-related evoked potentials. Less typical features include slowing of saccadic eye movements, the presence of vertical gaze palsy, visual hallucinations and an impaired electroretinogram (ERG). Aspects of primary vision such as visual acuity, colour vision or visual fields are usually unaffected. Management of the disease to deal with problems of walking, movement, daily tasks and speech problems is important in MSA. Optometrists can work in collaboration with the patient and health-care providers to identify and manage the patient's visual deficits. A more specific role for the optometrist is to correct vision to prevent falls and to monitor the anterior eye to prevent dry eye and control blepharospasm.
Resumo:
In this article we present an approach to object tracking handover in a network of smart cameras, based on self-interested autonomous agents, which exchange responsibility for tracking objects in a market mechanism, in order to maximise their own utility. A novel ant-colony inspired mechanism is used to learn the vision graph, that is, the camera neighbourhood relations, during runtime, which may then be used to optimise communication between cameras. The key benefits of our completely decentralised approach are on the one hand generating the vision graph online, enabling efficient deployment in unknown scenarios and camera network topologies, and on the other hand relying only on local information, increasing the robustness of the system. Since our market-based approach does not rely on a priori topology information, the need for any multicamera calibration can be avoided. We have evaluated our approach both in a simulation study and in network of real distributed smart cameras.
Resumo:
The etiology of primary open-angle glaucoma (POAG) remains the subject of continuing investigation. Despite the many known risk factors and mechanism of damage, the principal treatment objectives in POAG still consist of reduction of intraocular pressure, which although straightforward in many cases, often leaves the clinician with the question of how far to pursue a sufficiently low pressure to prevent further damage. Other risk factors such as hemodynamic insufficiency due to vascular dysregulation and abnormal blood pressure are often overlooked in the day-to-day practice; their harmful effects for glaucoma are, it seems, more potent at night while the patient sleeps and when clinical investigation is most difficult. Although the status of autonomic nervous system is an important determinant of the systemic hemodynamic parameters, this issue is usually ignored by the clinician in the process of glaucoma diagnosis. Consequently, there is a lack of alternative therapies tailored to address associated systemic risk factors for POAG on a case and chronological basis; this approach could be more effective in preventing the progression and visual loss in selected glaucoma cases. © 2004 Elsevier Inc. All rights reserved.
Resumo:
To explore the views of pharmacy and rheumatology stakeholders about system-related barriers to medicines optimisation activities with young people with long-term conditions. A three-phase consensus-building study comprising (1) focus groups with community and hospital pharmacists; (2) semi-structured telephone interviews with lay and professional adolescent rheumatology stakeholders and pharmacy policymakers, and (3) multidisciplinary discussion groups with community and hospital pharmacists and rheumatology staff. Qualitative verbatim transcripts from phases 1 and 2 were subjected to framework analysis. Themes from phase 1 underpinned a briefing for phase 2 interviewees. Themes from phases 1 and 2 generated elements of good pharmacy practice and current/future pharmacy roles for ranking in phase 3. Results from phase 3 prioritisation and ranking exercises were captured on self-completion data collection forms, entered into an Excel spreadsheet and subjected to descriptive statistical analysis. Institutional ethical approval was given by Aston University Health and Life Sciences Research Ethics Committee. Four focus groups were conducted with 18 pharmacists across England, Scotland and Wales (7 hospital, 10 community and 1 community/public health). Fifteen stakeholders took part in telephone interviews (3 pharmacist commissioners; 2 pharmacist policymakers; 2 pharmacy staff members (1 community and 1 hospital); 4 rheumatologists; 1 specialist nurse, and 3 lay juvenile arthritis advocates). Twenty-five participants took part in three discussion groups in adolescent rheumatology centres across England and Scotland (9 community pharmacists; 4 hospital pharmacists; 6 rheumatologists; 5 specialist nurses, and 1 physiotherapist). In all phases of the study, system-level issues were acknowledged as barriers to more engagement with young people and families. Community pharmacists in the focus groups reported that opportunities for engaging with young people were low if parents collected prescriptions alone, which was agreed by other stakeholders. Moreover, institutional/company prescription collection policies – an activity largely disallowed for a young person under 16 without an accompanying parent - were identified by hospital and community pharmacists as barriers to open discussion and engagement. Few community pharmacists reported using Medicines Use Review (England/Wales) or Chronic Medication Service (Scotland) as a medicines optimisation activity with young people; many were unsure about consent procedures. Despite these limitations, rheumatology stakeholders ranked highly the potential of pharmacists empowering young people with general health care skills, such as repeat prescription ordering. The pharmacy profession lacks vision for its role in the care of young people with long-term conditions. Pharmacists and rheumatology stakeholders identified system-level barriers to more engagement with young people who take medicines regularly. We acknowledge that the modest number of participants may have had a specific interest and thus bias for the topic, but this underscores their frank admission of the challenges. Professional guidance and policy, practice frameworks and institutional/company policies must promote flexibility for pharmacy staff to recognise and empower young people who are able to give consent and take responsibility for medicines activities. This will increase mutual confidence and trust, and foster pharmacy’s role in teaching general health care skills. In this way, pharmacists will be able to build long-term relationships with young people and families.
Resumo:
Our goal here is a more complete understanding of how information about luminance contrast is encoded and used by the binocular visual system. In two-interval forced-choice experiments we assessed observers' ability to discriminate changes in contrast that could be an increase or decrease of contrast in one or both eyes, or an increase in one eye coupled with a decrease in the other (termed IncDec). The base or pedestal contrasts were either in-phase or out-of-phase in the two eyes. The opposed changes in the IncDec condition did not cancel each other out, implying that along with binocular summation, information is also available from mechanisms that do not sum the two eyes' inputs. These might be monocular mechanisms. With a binocular pedestal, monocular increments of contrast were much easier to see than monocular decrements. These findings suggest that there are separate binocular (B) and monocular (L,R) channels, but only the largest of the three responses, max(L,B,R), is available to perception and decision. Results from contrast discrimination and contrast matching tasks were described very accurately by this model. Stimuli, data, and model responses can all be visualized in a common binocular contrast space, allowing a more direct comparison between models and data. Some results with out-of-phase pedestals were not accounted for by the max model of contrast coding, but were well explained by an extended model in which gratings of opposite polarity create the sensation of lustre. Observers can discriminate changes in lustre alongside changes in contrast.