32 resultados para flicker


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background/aims. The MacuScope uses a psychophysical technique called heterochromic flicker photometry to measure macular pigment optical density (MPOD). Our aim was to determine the measurement variability (noise) of the MacuScope. Methods. Thirty-eight normally sighted participants who ranged in age from 19 to 46 years (25.7±7.6 years) were recruited from staff and students of Aston University. Data were collected by two operators, HB and JA, in two sessions separated by 1 week in order to assess test repeatability and reproducibility. Results. The overall mean MPOD for the cohort was 0.47±0.14. There was a significant negative correlation between MacuScope MPOD readings and age (r=-0.368, p=0.023). Coefficients were 0.45 and 0.58 for repeatability, and 0.49 and 0.36 for reproducibility. For each pair of results, there was a significant positive correlation between mean and difference MPOD values. Conclusions. If MPOD is being monitored over time then any change less than 0.58 units should not be considered clinically significant as it is very likely to be due to instrument noise. The size of the coefficient appears to be positively correlated with MPOD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis considers the visual electrophysiological effects of vigabatrin (an anti-epileptic drug, which acts by increasing the levels of the inhibitory neurotransmitter GABA on the retina of the eye compared to the concentric visual field defects which have been found associated with the drug. Flash and pattern ERG's, EOG's multifocal ERG's (VERIS), flash and pattern VEP's and visual fields were tested. Although VEP's have been shown not to be affected by vigabatrin, these were recorded to complete the testing. Initially, of the eight vigabatrin patients with known visual field defects, 7 showed abnormally delayed 30Hz flicker a-wave latencies, 5 abnormally delayed 30Hz b-wave latencies and 6 abnormally low 30Hz amplitudes. Also 7 showed an abnormally prolonged latency of oscillatory potential 1 (OP1). The two patients taking vigabatrin at the time of testing showed low EOG Arden index values. The VERIS results correlated well with the severity of the visual field defects. Following this finding, eleven healthy subjects received vigabatrin over a 10-day period. No changes were seen in the visual fields, however, the photopic ERG b-wave latency significantly increased (although not to abnormal values). A matched pairs study with eleven vigabatrin, patients and eleven epileptic patients, who had never taken vigabatrin supported the findings of abnormal 30Hz flicker b-wave and OP latencies associated with vigabatrin, again with the VERIS results correlating to the severity of the visual field defect. The abnormal 30Hz flicker and VERIS responses indicate involvement of the cone photoreceptors and the OP's show an effect on the amacrine cells. The ERG increase in the photopic b-wave latency also suggests involvement of the bipolar cells, however, this effect and the reversible effect on the Arden index after cessation of the drug may be unrelated to the visual field defect. To conclude this thesis, a field specific VEP stimulus was developed to assess the retinal function in the peripheral field of paediatric patients. It comprises of a dartboard stimulus with a central 0-5 degree black and white chequered stimulus, a blank 5-30 degree annulus and a 30-60 degree peripheral chequered stimulus. When optimised on four vigabatrin patients it was found that no peripheral response can be evoked with a field loss exceeding 30-35 degrees. Co-operation was found to be successful in children as young as four years old.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The principal aim of this work was to examine the effects of antiepileptic drugs (AEDs) on vision. Vigabatrin acts by increasing GABA at brain inhibitory synapses by irreversibly binding to GABA-transaminase. Remacemide is a novel non-competitive NMDA receptor antagonist and fast sodium channel inhibitor that results in the inhibition of the NMDA receptors located in the neuronal membrane calcium channels increasing glutamate in the brain. Vigabatrin has been shown to cause a specific pattern of visual field loss, as one in three adults taking vigabatrin have shown a bilateral concentric constriction. Remacemide has unknown effects on vision. The majority of studies of the effects of AEDs on vision have not included the paediatric population due to difficulties assessing visual field function using standard perimetry testing. Evidently an alternative test is required to establish and monitor visual field problems associated with AEDs both in children and in adults who cannot comply with perimetry. In order to test paediatric patients exposed to vigabatrin, a field-specific visual evoked potential was developed. Other tests performed on patients taking either vigabatrin or remacemide were electroretinograms, electro-oculograms, multifocal VEPs and perimetry. Comparing these tests to perimetry results from vigabatrin patients the field specific VEP was found to have a high sensitivity and specificity, as did the 30Hz flicker amplitude. The modified VEP was also found to provide useful results in vigabatrin patients. Remacemide did not produce a similar visual field loss to vigabatrin although macular vision was affected. The field specific VEP is a useful method for detecting vigabatrin associated visual field loss that is well tolerated by young children. This technique combined with the ERG under light adapted (30Hz flicker) condition is presently the superior method for detecting vigabatrin-attributed peripheral field defects present in children below the developmental age of 9. The effects of AEDs on vision should be monitored carefully and the use of multifocal stimulation allows for specific areas of the retina and visual pathway to be monitored.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The observation that performance in many visual tasks can be made independent of eccentricity by increasing the size of peripheral stimuli according to the cortical magnification factor has dominated studies of peripheral vision for many years. However, it has become evident that the cortical magnification factor cannot be successfully applied to all tasks. To find out why, several tasks were studied using spatial scaling, a method which requires no pre-determined scaling factors (such as those predicted from cortical magnification) to magnify the stimulus at any eccentricity. Instead, thresholds are measured at the fovea and in the periphery using a series of stimuli, all of which are simply magnified versions of one another. Analysis of the data obtained in this way reveals the value of the parameter E2, the eccentricity at which foveal stimulus size must double in order to maintain performance equivalent to that at the fovea. The tasks investigated include hyperacuities (vernier acuity, bisection acuity, spatial interval discrimination, referenced displacement detection, and orientation discrimination), unreferenced instantaneous and gradual movement, flicker sensitivity, and face discrimination. In all cases tasks obeyed the principle of spatial scaling since performance in the periphery could be equated to that at the fovea by appropriate magnification. However, E2 values found for different spatial tasks varied over a 200-fold range. In spatial tasks (e.g. bisection acuity and spatial interval discrimination) E2 values were low, reaching about 0.075 deg, whereas in movement tasks the values could be as high as 16 deg. Using a method of spatial scaling it has been possible to equate foveal and peripheral perfonnance in many diverse visual tasks. The rate at which peripheral stimulus size had to be increased as a function of eccentricity was dependent upon the stimulus conditions and the task itself. Possible reasons for these findings are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the role of ophthalmic factors in dyslexia remains the subject of controversy, recent research has indicated that the correlates of dyslexia may include binocular dysfunction, unstable motor ocular dominance, a deficit of the transient visual subsystem, and an anomaly that can be treated with tinted lenses. These features, typically, have been studied in isolation and their inter-relationship has received little attention. The aim of the present research was to investigate ophthalmic factors in dyslexia, with a particular emphasis on the interaction between optometric variables. Further aims were to establish the most appropriate investigative techniques for optometric practice and to explore the relationship between optometric and psychometric variables. A pilot study was used to refine the experimental design for a subsequent detailed study of 39 children with a specific reading disability and 43 good readers, who were selected from 240 children. The groups were matched for age, sex, and performance IQ. The following factors emerged as correlates of dyslexia: slight impaired visual acuity; reduced vergence amplitudes; increased vergence instability; decreased accommodative amplitude; poor peformance at tests that were designed to assess the function of the transient visual system; and slightly slower performance at a non-verbal simulated reading visual search task. The `transient system deficit', as measured by reduced flicker sensitivity, was significantly associated with decreased accommodative and vergence amplitudes. This links the motor and sensory visual correlates of dyslexia. Although the binocular dysfunction was correlated with increased symptoms, the difference in the groups' simulated reading visual search task performance was largely attributable to psychometric variables. The results suggest tht optometric problems may be a contributory factor in dyslexia, but are unlikely to play a key causative role. Several optometric variables were confounded by psychometric parameters, and this interaction should be a priority for future investigation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was carried out of 45 migrainous patients with visually induced migraine (VIM), and 25 migrainous students, each having an age and sex matched control. The study utilised questionnaires, interviews, electroencephalography (EEG) and visual evoked potentials (VEP). The experimental work and analysis was carried out in the Neuropsychology Unit in collaboration with the Birmingham Migraine Clinic, over a period of five years. The study suggests: 1. The literature on a possible relationship between migraine and epilepsy hitherto published is unreliable (supporting evidence is given). 2. That a much greater precision is needed in defining migraine for research purposes. 3. A revised methodology for the selection of controls is needed and this is proposed. 4. That despite what are now seen to be superficial similarities, there are clear distinctions of a fundamental nature between photo-sensitive epilepsy (PSE) and VIM. 5. Caution be used when taking headache as a symptom, since many of the precipitants of migrainous headache can also precipitate non-migrainous headache (NMH). 6. The list of visual precipitants of migraine is expanded (particularly flicker and pattern). 7. That colour (principally red) is a previously unreported precipitant of migraine. 8. The extended range of responses to flicker (the 'H' response) has no significant difference in its frequency of occurrence in patients and normal controls, which contradicts previous literature. 9. The mechanisms thought to underlie migraine serve to explain previously unexplained EEG findings. 10. Further research is needed and proposed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background/aims To investigate ethnic differences in retinal vascular function and their relationship to traditional risk indicators for cardiovascular disease (CVD). Methods A total of 90 normoglycaemic subjects (45 South Asian (SA) and 45 age- and gender-matched white Europeans (WEs)) were recruited for the present study. Retinal vessel reactivity to flickering light was assessed by means of the dynamic retinal vessel analyser according to a modified protocol. Fasting plasma glucose, triglycerides (TG), total, LDL and HDL cholesterol were also measured in all individuals. Results SA individuals showed higher fasting triglyceride (p=0.001) and lower HDL levels (p=0.007), leading to a higher TG:HDL-C ratio (p=0.001) than age-matched WE subjects. Additionally, in SAs, the retinal arterial reaction time in response to flicker stimulation was significantly longer in the last flicker cycle than in the WEs (p=0.039), and this change correlated positively with measured plasma TG levels (r=0.60; p=0.01). No such relationship was observed in the WEs (p>0.05). Conclusion Even in the absence of overt vascular disease, in otherwise healthy SAs there are potential signs of retinal vascular function impairment that correlates with established plasma markers for CVD risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To establish an alternative method, sequential and diameter response analysis (SDRA), to determine dynamic retinal vessel responses and their time course in serial stimulation compared with the established method of averaged diameter responses and standard static assessment. METHODS. SDRA focuses on individual time and diameter responses, taking into account the fluctuation in baseline diameter, providing improved insight into reaction patterns when compared with established methods as delivered by retinal vessel analyzer (RVA) software. SDRA patterns were developed with measurements from 78 healthy nonsmokers and subsequently validated in a group of 21 otherwise healthy smokers. Fundus photography and retinal vessel responses were assessed by RVA, intraocular pressure by contact tonometry, and blood pressure by sphygmomanometry. RESULTS. Compared with the RVA software method, SDRA demonstrated a marked difference in retinal vessel responses to flickering light (P 0.05). As a validation of that finding, SDRA showed a strong relation between baseline retinal vessel diameter and subsequent dilatory response in both healthy subjects and smokers (P 0.001). The RVA software was unable to detect this difference or to find a difference in retinal vessel arteriovenous ratio between smokers and nonsmokers (P 0.243). However, SDRA revealed that smokers’ vessels showed both an increased level of arterial baseline diameter fluctuation before flicker stimulation (P 0.005) and an increased stiffness of retinal arterioles (P 0.035) compared with those in nonsmokers. These differences were unrelated to intraocular pressure or systemic blood pressure. CONCLUSIONS. SDRA shows promise as a tool for the assessment of vessel physiology. Further studies are needed to explore its application in patients with vascular diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of the following studies was to explore the effect of systemic vascular and endothelial dysfunction upon the ocular circulation and functionality of the retina. There are 6 principal sections to the present work. Retinal vessel activity in smokers and non-smokers: the principal findings of this work were: chronic smoking affects retinal vessel motion at baseline and during stimulation with flickering light; chronic smoking leads to a vaso-constrictory shift in retinal arteriolar reactivity to flicker; retinal arteriolar elasticity is decreased in chronic smokers. The effect of acute smoking on retinal vessel dynamics in smokers and non-smokers: the principal finding of this work was that retinal reactivity in chronic smokers is blunted when exposed to clicker light provocation immediately after smoking one cigarette. Ocular blood flow in coronary artery disease: The principal findings of this work were: retrobulbar and retinal blood flow is preserved in CAD patients, despite a change pulse wave transmission; arterial retinal response to flickering light provocation is significantly delayed in CAD patients; retinal venular diameters are significantly dilated in CAD patients. Autonomic nervous system function and peripheral circulation in CAD: The principal findings in this work were: CAD patients demonstrate a sympathetic overdrive during a 24 period; a delay in peripheral vascular reactivity (nail-fold capillaries) as observed in patients suffering from CAD could be caused by either arteriosclerotic changes of the vascular walls or due to systemic haemodynamic changes. Visual function in CAD: The principal findings in this work were: overall visual function in CAD patients is preserved, despite a decrease in contrast sensitivity; applying a filtering technique selecting those with greater coefficient of variance which in turn represents a decrease in reliability, some patients appear to have an impaired visual function as assessed using FDT visual field evaluation. Multiple functional, structural and biochemical vascular endothelial dysfunctions in patients suffering from CAD: relationships and possible implications: The principal findings of this work were: BMI significantly correlated with vWF (a marker of endothelial function) in CAD patients. Retinal vascular reactivity showed a significant correlation with peripheral reactivity parameters in controls which lacked in the CAD group and could reflect a loss in vascular endothelial integrity; visual field parameters as assessed by frequency doubling technology were strongly related with systemic vascular elasticity (ambulatory arterial stiffness index) in controls but not CAD patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The important role played by vascular factors in the pathogenesis of neurodegenerative disease has been increasingly realised over recent years. The nature and impact of ocular and systemic vascular dysfunction in the pathogenesis of comparable neurodegenerative diseases such as glaucoma and Alzheimer’s disease (AD) has however never been fully explored. The aim of this thesis was therefore to investigate the presence of macro- and micro-vascular alterations in both glaucoma and AD and to explore the relationships between these two chronic, slowly progressive neurodegenerative diseases. The principle sections and findings of this work were: 1. Is the eye a window to the brain? Retinal vascular dysfunction in Alzheimer’s disease · Mild newly diagnosed AD patients demonstrated ocular vascular dysfunction, in the form of an altered retinal vascular response to flicker light, which correlated with their degree of cognitive impairment. 2. Ocular and systemic vascular abnormalities in newly diagnosed normal tension glaucoma (NTG) patients · NTG patients demonstrated an altered retinal arterial constriction response to flicker light along with an increased systemic arterial stiffness and carotid artery intima-media thickness (IMT). These findings were not replicated by healthy age matched controls. 3. Ocular vascular dysregulation in AD compares to both POAG and NTG · AD patients demonstrated altered retinal arterial reactivity to flicker light which was comparable to that of POAG patients and altered baseline venous reactivity which was comparable to that of NTG patients. Neither alteration was replicated by healthy controls. 4. POAG and NTG: two separate diseases or one continuous entity? The vascular perspective · POAG and NTG patients demonstrated comparable alterations in nocturnal systolic blood pressure (SBP) variability, ocular perfusion pressure, retinal vascular reactivity, systemic arterial stiffness and carotid IMT. · Nocturnal SBP variability was found to correlate with both retinal artery baseline diameter fluctuation and carotid IMT across the glaucoma groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To investigate the relationship between vascular function parameters measured at the retinal and systemic level and known markers for cardiovascular risk in patients with impaired glucose tolerance (IGT). Sixty age- and gender- matched White-European adults (30 IGT and 30 normal glucose tolerance -NGT) were recruited for the study. Fasting plasma glucose, lipids and 24-hour blood pressure (BP) was measured in all subjects. Systemic vascular and endothelial function was assessed using carotid-artery intimal media thickness (cIMT) and flow mediated dilation (FMD). Retinal vascular reactivity was assessed by the Dynamic Retinal Vessel Analyser (DVA). Additionally, blood glutathione (GSH, GSSG and tGSH) and plasma von-Willebrand (vWF) factor levels were also measured. Individuals with IGT demonstrated higher BP values (p<0.001), fasting TG and TG:HDL ratios (p<0.001) than NGT subjects. Furthermore, Total:HDL-C ratios and Framingham scores were raised (p=0.010 and p<0.001 respectively). Blood glutathione levels (GSH, GSSG and tGSH) were lower (p<0.001, p=0.039 and p<0.001 respectively) while plasma vWF was increased (p=0.014) in IGT subjects compared to controls. IGT individuals also demonstrated higher IMT in right and left carotid arteries (p=0.017 and p=0.005, respectively) alongside larger brachial artery diameter (p=0.015), lower FMD% (p=0.026) and GTN induced dilation (GID) (p=0.012) than healthy controls. At the retinal arterial level, the IGT subjects showed higher baseline fluctuations (BDF) (p=0.026), longer reaction time (RT) (p=0.032) and reduced baseline-corrected flicker response (bFR) (p=0.045). In IGT subjects retinal BDF correlated with and Total:HDL (p= 0.003) and HDL-C (p= 0.004). Arterial RT also correlated with FMD (p=0.017) in IGT but not NGT subjects. In IGT individuals there is a relationship between macro- and microvascular function, as well as a direct correlation between the observed retinal microcirculatory changes and established plasma markers for CVD. Multifactorial preventive interventions to decrease vascular risk in these individuals should be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the range of macular pigment optical density (MPOD) in a healthy group of young adults of South Asian origin; to investigate whether any dietary factors or personal characteristics were related to inter-subject variations in MPOD; and to compare the mean MPOD of the South Asian group with the mean MPOD of a white group. Methods: Heterochromatic flicker photometry was used to measure the MP levels of 169 healthy volunteers, of which 117 were Asian and 52 were white. In addition, the Asian participants completed a questionnaire pertaining to the various physical, ocular, lifestyle, dietary and environmental factors that may be associated with MPOD or age-related macular degeneration (AMD). Results: The mean MPOD of the Asian subjects was 0.43±0.14. The male participants had a higher mean MPOD than the females (0.47±0.13 vs 0.41±0.14, p<0.01). Possible associations also emerged between MPOD and form of refractive correction, and iris colour. No MPOD associations were found for the other variables examined in the questionnaire. The mean MPOD of the white subject group was 0.33±0.13, which was significantly lower than the Asian group (p<0.0005). Conclusions: This study adds to the currently limited information on MPOD in South Asians, and while a comparison between Asians and Whites was not the main focus here, highly significant differences between these two ethnicities were revealed. This provokes the possibility that South Asian individuals could have a lower risk for AMD, and it warrants further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To investigate the coexistence of ocular microvascular and systemic macrovascular abnormalities in early stage, newly diagnosed and previously untreated normal tension glaucoma patients (NTG). Methods: Retinal vascular reactivity to flickering light was assessed in 19 NTG and 28 age-matched controls by means of dynamic retinal vessel analysis (IMEDOS GmbH, Jena, Germany). Using a newly developed computational model, the entire dynamic vascular response profile to flicker light was imaged and used for analysis. In addition, assessments of carotid intima-media thickness (IMT) and pulse wave analysis (PWA) were conducted on all participants, along with blood pressure (BP) measurements and blood analyses for lipid metabolism markers. Results: Patients with NTG demonstrated an increased right and left carotid IMT (p = 0.015, p = 0.045) and an elevated PWA augmentation index (p = 0.017) in comparison with healthy controls, along with an enhanced retinal arterial constriction response (p = 0.028), a steeper retinal arterial constriction slope (p = 0.031) and a reduced retinal venous dilation response (p = 0.026) following flicker light stimulation. Conclusions: Early stage, newly diagnosed, NTG patients showed signs of subclinical vascular abnormalities at both macro- and micro-vascular levels, highlighting the need to consider multi-level circulation-related pathologies in the development and progression of this type of glaucoma.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare and contrast the presence of ocular and systemic vascular function in newly diagnosed and previously untreated primary open angle glaucoma (POAG) and normal tension glaucoma (NTG) patients with comparable, early stage, functional loss. Methods: The systemic vascular function of 19 POAG patients, 19 NTG patients and 20 healthy controls was assessed by means of 24 hour ambulatory blood pressure (ABPM), peripheral pulse wave analysis (PWA) and carotid intima-media thickness (IMT). Retinal vascular reactivity to flicker light was assessed using dynamic retinal vessel analysis (DVA,IMEDOS, GmbH, Jena, Germany). Results: When compared to normal controls, both POAG and NTG patients exhibited similarly increased nocturnal systemic blood pressure variability (p=0.011); peripheral arterial stiffness (p=0.015), carotid IMT (p=0.040) and reduced ocular perfusion pressure (OPP) (p<0.001). Furthermore, on DVA analysis, both groups of glaucoma patients also exhibited steeper retinal arterial constriction slopes (slope AC) following cessation of flicker (p=0.007) and a similarly increased fluctuation in arterial and venous baseline diameter (p=0.008 and p=0.009 respectively) in comparison to controls. Conclusion: POAG and NTG patients exhibit similar alterations in both ocular and systemic circulation at the early stages of their disease process. This highlights not only the importance of considering vascular risk factors in both conditions, but also raises questions about the current separation of the two conditions into completely distinct clinical entities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease.Methods: Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index.Results: Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p<0.05). Arterial reaction time was linked to serum creatinine (p=0.036) and eGFR (p=0.039), venous reaction time was linked to creatinine clearance (p=0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p<0.001 and p=0.003 respectively) and the dilatation amplitude (p=0.038 and p=0.048 respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p=0.004) and dilatation amplitude (p=0.017), vWf was linked to the maximum constriction response (p=0.016), and creatinine clearance to the baseline diameter fluctuation (p=0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p=0.022). Conclusions: Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.