23 resultados para cost reduction


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fibre overlay is a cost-effective technique to alleviate wavelength blocking in some links of a wavelength-routed optical network by increasing the number of wavelengths in those links. In this letter, we investigate the effects of overlaying fibre in an all-optical network (AON) based on GÉANT2 topology. The constraint-based routing and wavelength assignment (CB-RWA) algorithm locates where cost-efficient upgrades should be implemented. Through numerical examples, we demonstrate that the network capacity improves by 25 per cent by overlaying fibre on 10 per cent of the links, and by 12 per cent by providing hop reduction links comprising 2 per cent of the links. For the upgraded network, we also show the impact of dynamic traffic allocation on the blocking probability. Copyright © 2010 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the thesis was to analyse several process configurations for the production of electricity from biomass. Process simulation models using AspenPlus aimed at calculating the industrial performance of power plant concepts were built, tested, and used for analysis. The criteria used in analysis were performance and cost. All of the advanced systems appear to have higher efficiencies than the commercial reference, the Rankine cycle. However, advanced systems typically have a higher cost of electricity (COE) than the Rankine power plant. High efficiencies do not reduce fuel costs enough to compensate for the high capital costs of advanced concepts. The successful reduction of capital costs would appear to be the key to the introduction of the new systems. Capital costs account for a considerable, often dominant, part of the cost of electricity in these concepts. All of the systems have higher specific investment costs than the conventional industrial alternative, i.e. the Rankine power plant; Combined beat and power production (CUP) is currently the only industrial area of application in which bio-power costs can be considerably reduced to make them competitive. Based on the results of this work, AsperiPlus is an appropriate simulation platform. How-ever, the usefulness of the models could be improved if a number of unit operations were modelled in greater detail. The dryer, gasifier, fast pyrolysis, gas engine and gas turbine models could be improved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Great Britain and Brazil healthcare is free at the point of delivery and based study only on citizenship. However, the British NHS is fifty-five years old and has undergone extensive reforms. The Brazilian SUS is barely fifteen years old. This research investigated the middle management mediation role within hospitals comparing managerial planning and control using cost information in Great Britain and Brazil. This investigation was conducted in two stages entailing quantitative and qualitative techniques. The first stage was a survey involving managers of 26 NHS Trusts in Great Britain and 22 public hospitals in Brazil. The second stage consisted of interviews, 10 in Great Britain and 22 in Brazil, conducted in four selected hospitals, two in each country. This research builds on the literature by investigating the interaction of contingency theory and modes of governance in a cross-national study in terms of public hospitals. It further builds on the existing literature by measuring managerial dimensions related to cost information usefulness. The project unveils the practice involved in planning and control processes. It highlights important elements such as the use of predictive models and uncertainty reduction when planning. It uncovers the different mechanisms employed on control processes. It also depicts that planning and control within British hospitals are structured procedures and guided by overall goals. In contrast, planning and control processes in Brazilian hospitals are accidental, involving more ad hoc actions and a profusion of goals. The clinicians in British hospitals have been integrated into the management hierarchy. Their use of cost information in planning and control processes reflects this integration. However, in Brazil, clinicians have been shown to operate more independently and make little use of cost information but the potential signalled for cost information use is seen to be even greater than that of their British counterparts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Central venous catheters have become an integral part of patient management however they are associated with many complications including infection. Despite efforts being made to reduce the incidence of such infect ions the problem continues to increase and has resource implications for the Health Service. Studies relating to the source of microorganisms causing CVC-associated infection, the cost of such infections and the efficacy of an antimicrobial catheter have been undertaken. Thirty patients who required a CVC as part of their medical management and underwent cardiac surgery had the distal tips of their catheters sampled whilst in situ. Sampling took place within 1 h of catheter placement. Bacteria were isolated from 16% of the catheter distal tips sampled in situ. The guidewires used to insert the devices were also contaminated (50%). When CVC were inserted via a protective sheath, avoiding contact with the skin. the incidence of microbial contamination was reduced. These findings suggest that despite rigorous skin disinfection and strict aseptic technique, viable microorganisms are impacted onto the distal tip of CVC during the insertion procedure. Needleless intravascular access devices have been introduced in order to reduce the incidence of need1estick injury. However, it was unclear whether such connectors would act as a portal of entry for microorganisms to CVC. The efficacy of these devices was investigated. Within the controlled laboratory environment it was demonstrated that needleless devices, when challenged with microorganisms, did not allow the passage of microbes when flu id was injected. This therefore suggested that the devices should not increase the risk of catheter colonisation. When used in clinical practice however microbial contamination of the needleless connectors was 55 % in comparison to the routinely used luer connectors (23%). The cost of infections associated with CVC was determined. Twenty patients catheterised with a CVC designed for long term use who were admitted to hospital with a presumptive diagnosis of catheter-related infection were studied. The treatment given specifically for this infection was costed. The mean cost of such an infection was £ 1781.81. Throughout the UK this may amount to £1.565.906 per annum. The cost of infections associated with CVC designed for short term use was estimated to be between 5 and 7 million pounds per annum in the UK. In an attempt to reduce both the incidence and cost of catheter- related infection antimicrobial CVC have been developed. The efficacy of a novel polyurethane CVC impregnated on both the internal and external catheter surface with the quaternary ammonium compound benzalkonium chloride was investigated. Eighty eight patients received an antimicrobial catheter and 78 patients a conventional polyurethane CVC. The anti-microbial CVC resulted in a reduction in microbial colonisation of the external and internal polymer surfaces as compared to the control device. The observed reduction in microbial colonisation with the anti-microbial CVC may decrease the likelihood of subsequent infection offering a useful approach to the prevention of catheter-related infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work described in this thesis is directed towards the reduction of noise levels in the Hoover Turbopower upright vacuum cleaner. The experimental work embodies a study of such factors as the application of noise source identification techniques, investigation of the noise generating principles for each major source and evaluation of the noise reducing treatments. It was found that the design of the vacuum cleaner had not been optimised from the standpoint of noise emission. Important factors such as noise `windows', isolation of vibration at the source, panel rattle, resonances and critical speeds had not been considered. Therefore, a number of experimentally validated treatments are proposed. Their noise reduction benefit together with material and tooling costs are presented. The solutions to the noise problems were evaluated on a standard Turbopower and the sound power level of the cleaner was reduced from 87.5 dB(A) to 80.4 db(A) at a cost of 93.6 pence per cleaner.The designers' lack of experience in noise reduction was identified as one of the factors for the low priority given to noise during design of the cleaner. Consequently, the fundamentals of acoustics, principles of noise prediction and absorption and guidelines for good acoustical design were collated into a Handbook and circulated at Hoover plc.Mechanical variations during production of the motor and the cleaner were found to be important. These caused a vast spread in the noise levels of the cleaners. Subsequently, the manufacturing processes were briefly studied to identify their source and recommendations for improvement are made.Noise of a product is quality related and a high level of noise is considered to be a bad feature. This project suggested that the noise level be used constructively both as a test on the production line to identify cleaners above a certain noise level and also to promote the product by `designing' the characteristics of the sound so that the appliance is pleasant to the user. This project showed that good noise control principles should be implemented early in the design stage.As yet there are no mandatory noise limits or noise-labelling requirements for household appliances. However, the literature suggests that noise-labelling is likely in the near future and the requirement will be to display the A-weighted sound power level. However, the `noys' scale of perceived noisiness was found more appropriate to the rating of appliance noise both as it is linear and therefore, a sound level that seems twice as loud is twice the value in noys and also takes into consideration the presence of pure tones, which even in the absence of a high noise level can lead to annoyance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measurement assisted assembly (MAA) has the potential to facilitate a step change in assembly efficiency for large structures such as airframes through the reduction of rework, manually intensive processes and expensive monolithic assembly tooling. It is shown how MAA can enable rapid part-to-part assembly, increased use of flexible automation, traceable quality assurance and control, reduced structure weight and improved aerodynamic tolerances. These advances will require the development of automated networks of measurement instruments; model based thermal compensation, the automatic integration of 'live' measurement data into variation simulation and algorithms to generate cutting paths for predictive shimming and drilling processes. This paper sets out an architecture for digital systems which will enable this integrated approach to variation management. © 2013 The Authors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The peak-to-average power ratio (PAPR) and optical beat interference (OBI) effects are examined thoroughly in orthogonal frequency-division multiplexing access (OFDMA)-passive optical networks (PONs) at a signal bit rate up to ∼ 20 Gb/s per channel using cost-effective intensity-modulation and direct-detection (IM/DD). Single-channel OOFDM and upstream multichannel OFDM-PONs are investigated for up to six users. A number of techniques for mitigating the PAPR and OBI effects are presented and evaluated including adaptive-loading algorithms such as bit/power-loading, clipping for PAPR reduction, and thermal detuning (TD) for the OBI suppression. It is shown that the bit-loading algorithm is a very efficient PAPR reduction technique by reducing it at about 1.2 dB over 100 Km of transmission. It is also revealed that the optimum method for suppressing the OBI is the TD + bit-loading. For a targeted BER of 1 × 10-3, the minimum allowed channel spacing is 11 GHz when employing six users. © 2013 Springer Science+Business Media New York.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Switched reluctance motors (SRMs) are gaining in popularity because of their robustness, low cost, and excellent high-speed characteristics. However, they are known to cause vibration and noise primarily due to the radial pulsating force resulting from their double-saliency structure. This paper investigates the effect of skewing the stator and/or rotor on the vibration reduction of the three-phase SRMs by developing four 12/8-pole SRMs, including a conventional SRM, a skewed rotor-SRM (SR-SRM), a skewed stator-SRM (SS-SRM), and a skewed stator and rotor-SRM (SSR-SRM). The radial force distributed on the stator yoke under different skewing angles is extensively studied by the finite-element method and experimental tests on the four prototypes. The inductance and torque characteristics of the four motors are also compared, and a control strategy by modulating the turn-ON and turn-OFF angles for the SR-SRM and the SS-SRM are also presented. Furthermore, experimental results validate the numerical models and the effectiveness of the skewing in reducing the motor vibration. Test results also suggest that skewing the stator is more effective than skewing the rotor in the SRMs.