37 resultados para astigmatism


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Previous research has indicated that schematic eyes incorporating aspheric surfaces but lacking gradient index are unable to model ocular spherical aberration and peripheral astigmatism simultaneously. This limits their use as wide-angle schematic eyes. This thesis challenges this assumption by investigating the flexibility of schematic eyes comprising aspheric optical surfaces and homogeneous optical media. The full variation of ocular component dimensions found in human eyes was established from the literature. Schematic eye parameter variants were limited to these dimensions. The levels of spherical aberration and peripheral astigmatism modelled by these schematic eyes were compared to the range of measured levels. These were also established from the literature. To simplify comparison of modelled and measured data, single value parameters were introduced; the spherical aberration function (SAF), and peripheral astigmatism function (PAF). Some ocular components variations produced a wide range of aberrations without exceeding the limits of human ocular components. The effect of ocular component variations on coma was also investigated, but no comparison could be made as no empirical data exists. It was demonstrated that by combined manipulation of a number of parameters in the schematic eyes it was possible to model all levels of ocular spherical aberration and peripheral astigmatism. However, the unique parameters of a human eye could not be obtained in this way, as a number of models could be used to produce the same spherical aberration and peripheral astigmatism, while giving very different coma levels. It was concluded that these schematic eyes are flexible enough to model the monochromatic aberrations tested, the absence of gradient index being compensated for by altering the asphericity of one or more surfaces.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The extent to which the surface parameters of Progressive Addition Lenses (PALs) affect successful patient tolerance was investigated. Several optico-physical evaluation techniques were employed, including a newly constructed surface reflection device which was shown to be of value for assessing semi-finished PAL blanks. Detailed physical analysis was undertaken using a computer-controlled focimeter and from these data, iso-cylindrical and mean spherical plots were produced for each PAL studied. Base curve power was shown to have little impact upon the distribution of PAL astigmatism. A power increase in reading addition primarily caused a lengthening and narrowing of the lens progression channel. Empirical measurements also indicated a marginal steepening of the progression power gradient with an increase in reading addition power. A sample of the PAL wearing population were studied using patient records and questionnaire analysis (90% were returned). This subjective analysis revealed the reading portion to be the most troublesome lens zone and showed that patients with high astigmatism (> 2.00D) adapt more readily to PALs than those with spherical or low cylindrical (2.00D) corrections. The psychophysical features of PALs were then investigated. Both grafting visual acuity (VA) and contrast sensitivity (CS) were shown to be reduced with an increase in eccentricity from the central umbilical line. Two sample populations (N= 20) of successful and unsuccessful PAL wearers were assessed for differences in their visual performance and their adaptation to optically induced distortion. The possibility of dispensing errors being the cause of poor patient tolerance amongst the unsuccessful wearer group was investigated and discounted. The contrast sensitivity of the successful group was significantly greater than that of the unsuccessful group. No differences in adaptation to or detection of curvature distortion were evinced between these presbyopic groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The work utilising a new material for contact lenses has fallen into three parts: Physioloeical considerations: Since the cornea is devoid of blood vessels, its oxygen is derived from the atmosphere. Early hydrophilic gel contact lenses interrupted the flow of oxygen and corneal insult resulted. Three techniques of fenestration were tried to overcome this problem. High speed drilling with 0.1 mm diameter twist drills. was found to be mechanically successful, but under clinical conditions mucous blockage of the fenestrations occurred. An investigation was made into the amount of oxygen arriving at the corneal interface; related to gel lens thickness. The results indicated an improvement in corneal oxygen as lens thickness was reduced. The mechanism is thought to be a form of mechanical pump. A series of clinical studies con:firmed the experimental work; the use of thin lenses removing the symptoms of corneal hypoxia. Design: The parameters of lens back curvature. lens thickness and lens diameter have been isolated and related to three criteria of vision (a) Visual acuity. (b) Visual stability and (c) Induced astigmatism. From the results achieved a revised and basically successful design of lens has been developed. Comparative study: The developed form of lens was compared with traditional lenses in a controlled survey. Twelve factors were assessed over a twenty week period of wear using a total of eighty four patients. The results of this study indicate that whilst the expected changes were noted with the traditional lens wearers, gel lens wearers showed no discernible change in any of the factors measured. ldth the exception of' one parameter. In addition to a description of' the completed l'iork. further investigations are ·sug~ested l'lhich. it is hoped. l'iould further improve the optical performance of gel lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To assess the stability of the Akreos AO intraocular lens (IOL) platform with a simulated toric design using objective image analysis. Setting: Six hospital eye clinics across Europe. Methods: After implantation in 1 eye of patients, IOLs with orientation marks were imaged at 1 to 2 days, 7 to 14 days, 30 to 60 days, and 120 to 180 days. The axis of rotation and IOL centration were objectively assessed using validated image analysis. Results: The study enrolled 107 patients with a mean age of 69.9 years ± 7.7 (SD). The image quality was sufficient for IOL rotation analysis in 91% of eyes. The mean rotation between the first day postoperatively and 120 to 180 days was 1.93 ± 2.33 degrees, with 96% of IOLs rotating fewer than 5 degrees and 99% rotating fewer than 10 degrees. There was no significant rotation between visits and no clear bias in the direction of rotation. In 71% of eyes, the dilation and image quality was sufficient for image analysis of centration. The mean change in centration between 1 day and 120 to 180 days was 0.21 ± 0.11 mm, with all IOLs decentering less than 0.5 mm. There was no significant decentration between visits and no clear bias in the direction of the decentration. Conclusion: Objective analysis of digital retroillumination images taken at different postoperative periods shows the aspheric IOL platform was stable in the eye and is therefore suitable for the application of a toric surface to correct corneal astigmatism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE. To compare axial length growth between white children with myopia wearing orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) over a 2-year period. METHODS. Subjects 6 to 12 years of age with myopia -0.75 to -4.00 diopters of sphere (DS) and astigmatism ≤1.00 diopters of cylinder (DC) were prospectively allocated OK or SV correction. Measurements of axial length (Zeiss IOLMaster), corneal topography, and cycloplegic refraction were taken at 6-month intervals. RESULTS. Thirty-one children were fitted with OK and 30 with SV. Following 24 months, axial length increased significantly over time for both the OK group (0.47 mm) and SV group (0.69 mm; P < 0.001), with a significant interaction between time and group (P = 0.05) reflecting a greater increase in the SV group. Significant differences in refraction were found over time, between groups and for the interaction between time and group for spherical (all P < 0.001) but not cylindrical components of refraction (all P > 0.05). Significantly greater corneal flattening was evident in the OK group for the flatter and steeper corneal powers and for corneal shape factor (all P ≤0.05). CONCLUSIONS. Orthokeratology contact lens wear reduces axial elongation in comparison to distance single-vision spectacles in children. © 2012 The Association for Research in Vision and Ophthalmology, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Premium intraocular lenses (IOLs) aim to surgically correct astigmatism and presbyopia following cataract extraction, optimising vision and eliminating the need for cataract surgery in later years. It is usual to fully correct astigmatism and to provide visual correction for distance and near when prescribing spectacles and contact lenses, however for correction with the lens implanted during cataract surgery, patients are required to purchase the premium IOLs and pay surgery fees outside the National Health Service in the UK. The benefit of using toric IOLs was thus demonstrated, both in standard visual tests and real-world situations. Orientation of toric IOLs during implantation is critical and the benefit of using conjunctival blood vessels for alignment was shown. The issue of centration of IOLs relative to the pupil was also investigated, showing changes with the amount of dilation and repeat dilation evaluation, which must be considered during surgery to optimize the visual performance of premium IOLs. Presbyopia is a global issue, of growing importance as life expectancy increases, with no real long-term cure. Despite enhanced lifestyles, changes in diet and improved medical care, presbyopia still presents in modern life as a significant visual impairment. The onset of presbyopia was found to vary with risk factors including alcohol consumption, smoking, UV exposure and even weight as well as age. A new technique to make measurement of accommodation more objective and robust was explored, although needs for further design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for refinement for optimum visual outcome in addition to outlining how premium IOLs may provide long-term and successful correction of astigmatism and presbyopia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. Setting: University vision clinic. Methods: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. Results: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F= 70.341; p< 0.001). Comparatively better acuities were observed around 180°, as anticipated (F= 3.775; p= 0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F= 2.190, p= 0.129) or high cylinder (F= 0.491, p= 0.617) or in the adapted astigmats (F= 0.120, p= 0.887). Conclusion: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect. © 2013 British Contact Lens Association.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose. To assess the relative clinical success of orthokeratology contact lenses (OK) and distance single-vision spectacles (SV) in children in terms of incidences of adverse events and discontinuations over a 2-year period. Methods. Sixty-one subjects 6 to 12 years of age with myopia of - 0.75 to - 4.00DS and astigmatism =1.00DC were prospectively allocated OK or SV correction. Subjects were followed at 6-month intervals and advised to report to the clinic immediately should adverse events occur. Adverse events were categorized into serious, significant, and non-significant. Discontinuation was defined as cessation of lens wear for the remainder of the study. Results. Thirty-one children were corrected with OK and 30 with SV. A higher incidence of adverse events was found with OK compared with SV (p < 0.001). Nine OK subjects experienced 16 adverse events (7 significant and 9 non-significant). No adverse events were found in the SV group. Most adverse events were found between 6 and 12 months of lens wear, with 11 solely attributable to OK wear. Significantly more discontinuations were found with SV in comparison with OK (p < 0.05). Conclusions. The relatively low incidence of adverse events and discontinuations with OK is conducive for the correction of myopia in children with OK contact lenses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare vision-related quality-of-life measures between children wearing orthokeratology (OK) contact lenses and distance single-vision (SV) spectacles. Methods: Subjects 6 to 12 years of age and with myopia of -0.75 to -4.00 diopters and astigmatism less than or equal to 1.00 diopters were prospectively assigned OK contact lens or SV spectacle correction. A pediatric refractive error profile questionnaire was administered at 12- and 24-month intervals to evaluate children's perceptions in terms of overall vision, near vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, and peer perceptions. The mean score of all items was calculated as the overall score. Additionally, parents/guardians were asked to rate their child's mode of visual correction and their intention to continue treatment after study completion. Results: Thirty-one children were fitted with OK contact lenses and 30 with SV spectacles. Children wearing OK contact lenses rated overall vision, far distance vision, symptoms, appearance, satisfaction, activities, academic performance, handling, peer perceptions, and the overall score significantly better than children wearing SV spectacles (all P<0.05). Near vision and handling were, respectively, rated better (P<0.001) and similar (P=0.44) for SV spectacles in comparison to OK contact lenses. No significant differences were found between 12 and 24 months for any of the subjective ratings assessed (all P>0.05). Parents/guardians of children wearing OK contact lenses rated visual correction method and intention to continue treatment higher than parents of children wearing SV spectacles (P=0.01). Conclusion: The results indicate that the significant improvement in vision-related quality of life and acceptability with OK contact lenses is an incentive to engage in its use for the control of myopia in children.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Tilted disc syndrome has been described to be associated with obliquely directed long axis of the disc, oblique direction of vessels, retinal pigment epithelial conus, hypoplasia of retina, visual field defects and myopic astigmatism. This prospective study looks at corneal astigmatism in eyes with a tilted optic disc. Refractive errors in these eyes were also analyzed. Methods: Patients with tilted optic discs were identified prospectively by clinical evaluation (BI, VK). All the patients with obliquely directed long axis of the disc, oblique direction of vessels and retinal pigment epithelial conus were included in the study. Best corrected visual acuity, slit-lamp examination, optic disc measurements, keratometry and refraction were recorded. Results: Twenty four patients (41 eyes) were recruited for the study. Eighteen (75%) patients had bilateral tilted optic discs. Eighteen patients (75%) were females and six (25%) were males. The mean age was 62 years(range 9 – 86 years). 76% of the patients were myopic and 24% hypermetropic. The mean spherical equivalent was –7.49 dioptres (SD 1.7D, range +6D to -17D). The mean corneal astigmatism was 1.09D (SD 0.9D, range 0.25D to 3.80D). The 6 patients who had unilateral, untilted discs were used as a control group to compare their mean corneal astigmatism (1.32 D) with the rest. Student "t" test was performed. ("p" = 0.49). Conclusions: In our study, tilted disc syndrome was found to be largely bilateral and more commonly seen in females. Myopia was the commonest refractive error associated with this clinical condition. However, 24% of patients in this series were hypermetropic. No correlation between the tilting of the optic disc and significant corneal astigmatism was noted as previously reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

For more than a century it has been known that the eye is not a perfect optical system, but rather a system that suffers from aberrations beyond conventional prescriptive descriptions of defocus and astigmatism. Whereas traditional refraction attempts to describe the error of the eye with only two parameters, namely sphere and cylinder, measurements of wavefront aberrations depict the optical error with many more parameters. What remains questionable is the impact these additional parameters have on visual function. Some authors have argued that higher-order aberrations have a considerable effect on visual function and in certain cases this effect is significant enough to induce amblyopia. This has been referred to as ‘higher-order aberration-associated amblyopia’. In such cases, correction of higher-order aberrations would not restore visual function. Others have reported that patients with binocular asymmetric aberrations display an associated unilateral decrease in visual acuity and, if the decline in acuity results from the aberrations alone, such subjects may have been erroneously diagnosed as amblyopes. In these cases, correction of higher-order aberrations would restore visual function. This refractive entity has been termed ‘aberropia’. In order to investigate these hypotheses, the distribution of higher-order aberrations in strabismic, anisometropic and idiopathic amblyopes, and in a group of visual normals, was analysed both before and after wavefront-guided laser refractive correction. The results show: (i) there is no significant asymmetry in higher-order aberrations between amblyopic and fixing eyes prior to laser refractive treatment; (ii) the mean magnitude of higher-order aberrations is similar within the amblyopic and visually normal populations; (iii) a significant improvement in visual acuity can be realised for adult amblyopic patients utilising wavefront-guided laser refractive surgery and a modest increase in contrast sensitivity was observed for the amblyopic eye of anisometropes following treatment (iv) an overall trend towards increased higher-order aberrations following wavefront-guided laser refractive treatment was observed for both visually normal and amblyopic eyes. In conclusion, while the data do not provide any direct evidence for the concepts of either ‘aberropia’ or ‘higher-order aberration-associated amblyopia’, it is clear that gains in visual acuity and contrast sensitivity may be realised following laser refractive treatment of the amblyopic adult eye. Possible mechanisms by which these gains are realised are discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To compare lens orientation and rotational recovery of five currently available soft toric lenses. Methods: Twenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared. Results: The Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P=. 0.004) and rotational recovery (P<. 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P<. 0.05). Conclusion: Although there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.