125 resultados para Zhou, Chen, 1381-1453


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A low-cost high-resolution wavelength-division-multiplexing (WDM) interrogation system operating around 800 nm region with operational bandwidth up to 60 nm and resolution of 12.7 pm utilizing a tilted fiber Bragg grating (TFBG) and a CCDarray detector has been implemented. The system has been evaluated for interrogating fiber Bragg grating based strain, temperature sensors, giving sensitivities of 0.59 pm/µe and 5.6 pm/°C, which are in good agreement with previously reported values. Furthermore, the system has been utilized to detect the refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10¯5. In addition, the vectorial expression of phase match condition and fabrication of TFBG have been discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an in-fiber polarizer implemented using a 45° tilted FBG. Polarization extinction ratio of 28dB at 1550nm and HMFW over 80nm has been demonstrated. When the un-polarized light passes this device, 99.5% of degree of polarization can be achieved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single polarisation operation of fibre ring laser has been realised by employing an intracavity 45deg-tilted fibre Bragg grating (45deg-TFBG). The degree of polarisation up to 99.94% of the laser was demonstrated with good stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Single polarisation operation of fibre ring laser has been realised by employing an intracavity 45°tilted fibre Bragg gratings (45° TFBGs). The degree of polarisation of 99.94% of the laser was demonstrated with good stability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an implementation of optical fibre sensors based on fibre Bragg gratings with excessively tilted (>45°) structures, showing distinctive polarisation characteristics, desirable low thermal-cross-sensitivity and enhanced responsivity to surrounding-medium-refractive-index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report for the first time forward propagating cladding modes coupling by using tilted gratings. The spectral responses of these gratings were investigated and their thermal characteristics and sensitivity to environmental refractive index were evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the implementation of vector bending sensors using long-period gratings (LPGs) UV-inscribed in flat-clad, four-core and D-shaped fibres. Our experiments reveal a strong fibre-orientation dependence of the spectral response when such LPGs are subjected to dynamic bending, which provided an opportunity to realize curvature measurement with direction recognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two-dimensional optical power distribution of the out-coupled radiation from UV-inscribed tilted fibre Bragg gratings (TFBGs) in multimode fibre (MMF) has been side-detected with high spatial/spectral resolution, showing a near-identical radiation mode profile to that measured from the fibre-end detection method. A comparative investigation of the radiation characteristics of TFBGs fabricated in singlemode fibre (SMF) and MMF clearly indicates that the radiation out-coupling is stronger and spatially more confined in MMF. The unique spatial-to-spectral encoding property of the coupling mechanism offers potential application in low-cost WDM devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have experimentally investigated the mode dispersion property and refractive index sensitivity of dual-peak long-period fiber gratings (LPGs) that were sensitized by hydrofluoric acid (HF) etching. The nature of the coupled cladding modes close to the dispersion turning point makes the dual-peak LPGs ultrasensitive to cladding property, permitting a fine tailoring of the mode dispersion and index sensitivity by the light cladding etching method using HF acid of only 1% concentration. As an implementation of an optical biosensor, the etched device was used to detect the concentration of hemoglobin protein in a sugar solution, showing a sensitivity as high as 20 nm/1%.