23 resultados para TRANSIENT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the magnitude of nearwork-induced transient myopia (NITM) under binocular viewing conditions separately in each eye of individuals with mild to moderate anisometropia to determine the relationship between NITM and their interocular refractive error. Methods: Forty-three children and young adults with anisometropia [cycloplegic spherical equivalent (SE) difference >1.00 D] were tested (ages 9-28 years). NITM was measured with binocular viewing separately in each eye after binocularly performing a sustained near task (5 D) for 5 min incorporating a cognitive demand using an open-field, infrared autorefractor (Grand-Seiko, WAM-5500). Data were averaged over 10 s bins for 3 min in each eye. Initial NITM, its decay time (DT), and its decay area (DA) were determined. A-scan ultrasound ocular biometry was also performed to determine the axial length of each eye. Results: The more myopic eye exhibited increased initial NITM, DT, and DA as compared to the less myopic eye (0.21 ± 0.16 D vs 0.15 ± 0.13 D, p = 0.026; 108.4 ± 64.3 secs vs 87.0 ± 65.2 secs, p = 0.04; and 17.6 ± 18.7 D*secs vs 12.3 ± 15.7 D*secs, p = 0.064), respectively. The difference in DA and the difference in SE between the more versus less myopic eye were significantly correlated (r = 0.31, p = 0.044). Furthermore, 63% (27/43), 56% (24/43), and 70% (30/43) of the more myopic eyes exhibited increased initial NITM, longer DT, and larger DA, respectively, than found in the less myopic eye. Conclusions: In approximately two-thirds of the anisometropic individuals, the initial NITM and its decay area were significantly increased in the more myopic eye as compared to the less myopic eye. NITM may play an important role in the development of interocular differences in myopia, although a causal relationship is yet to be established. Furthermore, the findings have potentially important implications regarding accommodative control and interocular accommodative responsitivity in anisometropia, in particular for anisomyopia. © 2013 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A distributed temperature sensor for transient threshold monitoring with a 22 km sensing length, based on the Brillouin loss in standard communications fibre, is demonstrated. The system can be used for real-time monitoring of a preset temperature threshold. Good S/N ratios were achieved with only 8–16 sample averages giving a response time of 2 to 4 s with a temperature uncertainty of ±1 °C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. Whereas many previous studies have identified the association between sustained near work and myopia, few have assessed the influence of concomitant levels of cognitive effort. This study investigates the effect of cognitive effort on near-work induced transient myopia (NITM). Methods. Subjects comprised of six early onset myopes (EOM; mean age 23.7 yrs; mean onset 10.8 yrs), six late-onset myopes (LOM; mean age 23.2 yrs; mean onset 20.0 yrs) and six emmetropes (EMM; mean age 23.8 yrs). Dynamic, monocular, ocular accommodation was measured with the Shin-Nippon SRW-5000 autorefractor. Subjects engaged passively or actively in a 5 minute arithmetic sum checking task presented monocularly on an LCD monitor via a Badal optical system. In all conditions the task was initially located at near (4.50 D) and immediately following the task instantaneously changed to far (0.00 D) for a further 5 minutes. The combinations of active (A) and passive (P) cognition were randomly allocated as P:P; A:P; A:A; P:A. Results. For the initial near task, LOMs were shown to have a significantly less accurate accommodative response than either EOMs or EMMs (p < 0.001). For the far task, post hoc analyses for refraction identified EOMs as demonstrating significant NITM compared to LOMs (p < 0.05), who in turn showed greater NITM than EMMs (p < 0.001). The data show that for EOMs the level of cognitive activity operating during the near and far tasks determines the persistence of NITM; persistence being maximal when active cognition at near is followed by passive cognition at far. Conclusions. Compared with EMMs, EOMs and LOMs are particularly susceptible to NITM such that sustained near vision reduces subsequent accommodative accuracy for far vision. It is speculated that the marked NITM found in EOM may be a consequence of the crystalline lens thinning shown to be a developmental feature of EOM. Whereas the role of small amounts of retinal defocus in myopigenesis remains equivocal, the results show that account needs to be taken of cognitive demand in assessing phenomena such as NITM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whereas there are numerous reported ocular side effects from systemic sulpha medication, most are rare and reversible, with myopia being the most common reaction observed. A case report is presented of sudden bilateral onset of -1.0 DS of myopia (from -3.0 to -4.0 DS) in a young adult female following the addition of a sulphonamide (sulphasalazine) to oral non-steroidal anti-inflammatory treatment (meloxicam) for rheumatoid arthritis. The myopia regressed to -3.50 DS after 2 weeks when all medication was withdrawn and stabilised at this level when subsequent treatment was resumed after 8 weeks with the non-steroidal anti-inflammatory drug celecoxib. The case indicates that account needs to be taken of the possibility that relatively modest myopic shifts encountered in young adult contact lens wearers may be associated with concomitant systemic medication. © 2003 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To compare the magnitude and time course of nearwork-induced transient myopia (NITM) in preadolescent Hong Kong Chinese myopes and emmetropes. METHOD. Forty-five Hong Kong Chinese children, 35 myopes and 10 emmetropes aged 6 to 12 years (median, 7.5), monocularly viewed a letter target through a Badal lens for 5 minutes at either 5.00- or 2.50-D accommodative demand, followed by 3 minutes of viewing the equivalent target at optical infinity. Accommodative responses were measured continuously with a modified, infrared, objective open-field autorefractor. Accommodative responses were also measured for a countercondition: viewing of a letter target for 5 minutes at optical infinity, followed by 3 minutes of viewing the target at a 5.00-D accommodative demand. The results were compared with tonic accommodation and both subject and family history of refractive error. RESULTS. Retinal-blur-driven NITM was significantly greater in Hong Kong Chinese children with myopic vision than in the emmetropes after both near tasks, but showed no significant dose effect. The NITM was still evident 3 minutes after viewing the 5.00-D near task for 5 minutes. The magnitude of NITM correlated with the accommodative drift after viewing a distant target for more than 4 minutes, but was unrelated to the subjects' or family history of refractive error. CONCLUSIONS. In a preadolescent ethnic population with known predisposition to myopia, there is a significant posttask blur-driven accommodative NITM, which is sustained for longer than has previously been found in white adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We perform numerical simulations on a model describing a Brillouin-based temperature and strain sensor, testing its response when it is probed with relatively short pulses. Experimental results were recently published [e.g., Opt. Lett. 24, 510 (1999)] that showed a broadening of the Brillouin loss curve when the probe pulse duration is reduced, followed by a sudden and rather surprising reduction of the linewidth when the pulse duration gets shorter than the acoustic relaxation time. Our study reveals the processes responsible for this behavior. We give a clear physical insight into the problem, allowing us to define the best experimental conditions required for one to take the advantage of this effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Transient fully reconfigurable photonic circuits can be introduced at the optical fiber surface with subangstrom precision. A building block of these circuits - a 0.7Å-precise nano-bottle resonator - is experimentally created by local heating, translated, and annihilated.