32 resultados para SHORT-CONTACT TIMES
Resumo:
Purpose: Dynamic contact angle (DCA) methods have advantages over other contact angle methodologies, not least that they can provide more than single contact angle values. Here we illustrate the use of DCA analysis to provide “fingerprint” characterisation of contact lens surfaces, and the way that different materials change in the early stages of wear. Method: The DCA method involves attaching to a microbalance weighted strips cut from a lens. The strips are then cyclically inserted into and removed from an aqueous solution. Conventionally, readings of force taken from linear portions of the resultant dipping curves are translated into advancing (CAa) and receding contact (CAr) angles. Additionally, analysis of the force versus immersion profile provides a “fingerprint” characterisation of the state of the lens surface. Results: CAa and CAr values from DCA traces provide a useful means of differentiating gross differences in hydrophilicity and molecular mobility of surfaces under particular immersion and emersion conditions, such as dipping rate and dwell times. Typical values for etafilcon A (CAa:63.1; CAr:37) and balafilcon B (CAa:118.4; CAr:36.4) illustrate this. Surface modifications induced in lens manufacture are observed to produce not only changes in these value, which may be small, but also changes in the DCA “fingerprint” (slope, undulations, length of plateau). Interestingly, similar changes are induced in the first few hours of lens wear with some lens-patient combinations. Conclusions: Although single parameter contact angles are useful for material characterisation, information of potential clinical interest can be obtained from more detailed analysis of DCA traces.
Resumo:
The effect of stainless steel, glass, zirconium and titanium enamel surfaces on the thermal and photooxidative toughening mechanism of dehydrated castor oil films deposited on these surfaces was investigated using different analytical and spectroscopic methods. The conjugated and non-conjugated double bonds were identified and quantified using both Raman spectroscopy and 1D and 2D NMR spectroscopy. The disappearance of the double bonds in thermally oxidised oil-on-surface films was shown to be concomitant with the formation of hydroperoxides (determined by iodometric titration). The type of the surface had a major effect on the rate of thermal oxidation of the oil, but all of the surfaces examined had resulted in a significantly higher rate of oxidation compared to that of the neat oil. The highest effect was exhibited by the stainless steel surface followed by zirconium enamel, titanium enamel and glass. The rate of thermal oxidation of the oil-on-steel surface (at 100 °C, based on peroxide values) was more than five times faster than that of oil-on-glass and more than 21 times faster than the neat oil when compared under similar thermal oxidative conditions. The rate of photooxidation at 60 °C of oil-on-steel films was found to be about one and half times faster than their rate of thermal oxidation at the same temperature. Results from absorbance reflectance infrared microscopy with line scans taken across the depth of thermally oxidised oil-on-steel films suggest that the thermal oxidative toughening mechanism of the oil occurs by two different reaction pathways with the film outermost layers, i.e. furthest away from the steel surface, oxidising through a traditional free radical oxidation process involving the formation of various oxygenated products formed from the decomposition of allylic hydroperoxides, whereas, in the deeper layers closer to the steel surface, crosslinking reactions predominate.
Resumo:
Purpose - We performed a study of laser panretinal photocoagulation in 20 patients with proliferative retinopathy. We compared short exposure, high-energy laser settings with conventional settings, using a 532?nm, frequency doubled, Neodymium–Yag laser and assessed the patients in terms of pain experienced and effectiveness of treatment. Methods - Twenty patients having panretinal photocoagulation for the first time underwent random allocation to treatment of the superior and inferior hemi-retina. Treatment A used ‘conventional’ parameters: exposure time 0.1?s, power sufficient to produce a visible grey-white burns, spot size 300?µm. The other hemi- retina was treated with treatment B using exposure 0.02?s, 300?µm and sufficient power to have similar endpoint. All patients were asked to evaluate severity of pain on a visual analogue scale. (0=no pain, 10=most severe pain). All patients were masked as to the type of treatment and the order of carrying out the treatment on each patient was randomised. Patients underwent fundus photography and were followed up for 6–45 months. Results - Seventeen patients had proliferative diabetic retinopathy, two had ischaemic central retinal vein occlusion and one had ocular ischaemic syndrome. The mean response to treatment A was 5.11, compared to 1.40 treatment B, on the visual analogue scale, which was statistically significant (P=0.001). All patients preferred treatment B. Further treatments, if required, were performed with treatment B parameters and long-term follow-up has shown no evidence of undertreatment. Conclusions - Shortening exposure time of retinal laser is significantly less painful but equally effective as conventional parameters.
Resumo:
Purpose: to evaluate changes in tear metrics and ocular signs induced by six months of silicone-hydrogel contact lens wear and the difference in baseline characteristics between those who successfully continued in contact lens wear compared to those that did not. Methods: Non-invasive Keratograph, Tearscope and fluorescein tear break-up times (TBUTs), tear meniscus height, bulbar and limbal hyperaemia, lid-parallel conjunctival folds (LIPCOF), phenol red thread, fluorescein and lissamine-green staining, and lid wiper epitheliopathy were measured on 60 new contact lens wearers fitted with monthly silicone-hydrogels (average age 36 ± 14 years, 40 females). Symptoms were evaluated by the Ocular Surface Disease Index (OSDI). After six months full time contact lens wear the above metrics were re-measured on those patients still in contact lens wear (n= 33). The initial measurements were also compared between the group still wearing lenses after six months and those who had ceased lens wear (n= 27). Results: There were significant changes in tear meniscus height (p= 0.031), bulbar hyperaemia (p= 0.011), fluorescein TBUT (p= 0.027), corneal (p= 0.007) and conjunctival (p= 0.009) staining, LIPCOF (p= 0.011) and lid wiper epitheliopathy (p= 0.002) after six months of silicone-hydrogel wear. Successful wearers had a higher non-invasive (17.0 ± 8.2. s vs 12.0 ± 5.6. s; p= 0.001) and fluorescein (10.7 ± 6.4. s vs 7.5 ± 4.7. s; p= 0.001) TBUT than drop-outs, although OSDI (cut-off 4.2) was also a strong predictor of success. Conclusion: Silicone-hydrogel lenses induced significant changes in the tear film and ocular surface as well as lid margin staining. Wettability of the ocular surface is the main factor affecting contact lens drop-out. © 2013 British Contact Lens Association.
Resumo:
Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.
Resumo:
Readers may have noted that a short but very important announcement was made in the last issue of CLAE, at the top of the contents page. CLAE has been accepted by Thomson Reuters for abstracting and indexing in its SciSearch, Journal Citation Reports, and Current Contents services. This will ensure a greater visibility to the international research community. In addition, in June 2012 CLAE will receive its very first official Impact Factor – a measure of journal influence of importance to authors and readers alike. The impact factor value has not yet been decided but internal estimates by Elsevier estimate it will be around 1, and it will be applied to all CLAE issue back to January 2009 (volume 32). I would guess readers at this stage would have one of two responses – either ‘that's good news’ or perhaps ‘what's an impact factor?’ If you are in the latter camp then allow me to try and explain. Basically the impact factor or citation index of a journal is based on how many times in the previous year papers published in that journal in the previous two years were cited by authors publishing in other journals. So the 2012 impact factor for CLAE is calculated on how many times in 2011 papers that were published in CLAE in 2010 and 2009 were cited in other journals in 2011, divided by the number of papers published in CLAE 2010 and 2009. Essentially authors will try and get their work published in journals with a higher impact factor as it is thought that the paper will be cited more by other authors or the paper will have higher visibility in the arena. For universities having its published output in higher journals is one of the markers used to judge esteem. For individual authors publishing in journals with a higher impact factor or the number of times one of their papers is published is something that they are likely to add to their CVs or demonstrate the importance of their work. Journals with higher impact factors tend to be more review journals or journals with a wider spectrum so for a relatively small journal with a specialised field like CLAE it is great to be listed with a citation index. The awarding of a citation index crowns many changes that CLAE has undergone since the current Editor took the reins in 2005. CLAE has increased from four issues (in 2004) to six issues per year with at least one review article per issue and one article with continuing education per issue. The rejection rate has gone up significantly meaning that only best papers are published (currently it stands at 37%). CLAE has been Medline/Pubmed indexed for a few years now which is also a very important factor in improving visibility of the journal. The submission and reviewing process for CLAE in now entirely online and finally the editorial board has changed from being merely a list of keynote people to being an active group of keynote people who are enthusiastically involved with the journal. From the editorial board one person is appointed as a Reviews Editor plus we have two additional editors who work as Regional Editors. As ever, on behalf of CLAE I would like to thank the BCLA Council for their continued support (especially Vivien Freeman) and Elsevier for their continuing guidance (in particular Andrew Miller and Rosie Davey) and the excellent Editorial Board (Christopher Snyder, Pauline Cho, Eric Papas, Jan Bergmanson, Roger Buckley, Patrick Caroline, Dwight Cavanagh, Robin Chalmers, Michael Doughty, Nathan Efron, Michel Guillon, Nizar Hirji, Meng Lin, Florence Malet, Philip Morgan, Deborah Sweeney, Brian Tighe, Eef van Der Worp, Barry Weissman, Mark Willcox, James Wolffsohn and Craig Woods). And finally, a big thanks to the authors and reviewers who work tirelessly putting manuscripts together for publication in CLAE. Copyright © 2012 Published by Elsevier Ltd.
Resumo:
OBJECTIVE: To assess refractive and biometric changes 1 week after discontinuation of lens wear in subjects who had been wearing orthokeratology (OK) contact lenses for 2 years. METHODS: Twenty-nine subjects aged 6 to 12 years and with myopia of -0.75 to -4.00 diopters (D) and astigmatism of ≤1.00 D participated in the study. Measurements of axial length and anterior chamber depth (Zeiss IOLMaster), corneal power and shape, and cycloplegic refraction were taken 1 week after discontinuation and compared with those at baseline and after 24 months of lens wear. RESULTS: A hyperopic shift was found at 24 months relative to baseline in spherical equivalent refractive error (+1.86±1.01 D), followed by a myopic shift at 1 week relative to 24 months (-1.93±0.92 D) (both P<0.001). Longer axial lengths were found at 24 months and 1 week in comparison to baseline (0.47±0.18 and 0.51±0.18 mm, respectively) (both P<0.001). The increase in axial length at 1 week relative to 24 months was statistically significant (0.04±0.06 mm; P=0.006). Anterior chamber depth did not change significantly over time (P=0.31). Significant differences were found between 24 months and 1 week relative to baseline and between 1-week and 24-month visits in mean corneal power (-1.68±0.80, -0.44±0.32, and 1.23±0.70 D, respectively) (all P≤0.001). Refractive change at 1 week in comparison to 24 months strongly correlated with changes in corneal power (r=-0.88; P<0.001) but not with axial length changes (r=-0.09; P=0.66). Corneal shape changed significantly between the baseline and 1-week visits (0.15±0.10 D; P<0.001). Corneal shape changed from a prolate to a more oblate corneal shape at the 24-month and 1-week visits in comparison to baseline (both P≤0.02) but did not change significantly between 24 months and 1 week (P=0.06). CONCLUSIONS: The effects of long-term OK on ocular biometry and refraction are still present after 1-week discontinuation of lens wear. Refractive change after discontinuation of long-term OK is primarily attributed to the recovery of corneal shape and not to an increase in the axial length.
Resumo:
Biochemical changes brought about by the influence of the contact lens on the tear film are conveniently split into two categories. Firstly, the lens can remove or reduce the levels of specific components in the tear film, and secondly, the lens can augment the tear film, by stimulating the influx of new components or increasing the level of existing components. The most obvious tear film components for study in this context are lipids, proteins, mucins and electrolytes. The interactions are affected by the properties of the lens, the characteristics of the individual wearer and the wear schedule. An additional complicating factor is the fact that the lens is many times thicker than the tear film and any immobilised tear components will be more extensively exposed to oxygen and UV radiation than is the case in the absence of a lens. It is arguably the lipoidal components that are most markedly affected by lens wear, since their immobilisation on the lens surface markedly increases their susceptibility to autoxidative degradation. The limited information that is available highlights the importance of subject specificity and suggests that lipid oxidation phenomena are potentially important in contributing to the 'end of day' discomfort of symptomatic contact lens patients. It is clear that tear lipids, although regarded as relatively inert for many years, are now seen as a reactive and potentially important family of compounds in the search for understanding of contact lens-induced discomfort. The influence of the lens on tear proteins shows the greatest range of complexity. Deposition and denaturation can stimulate immune response, lower molecular weight proteins can be extensively absorbed into the lens matrix and the lens can stimulate cascade or upregulation processes leading either to the generation of additional proteins and peptides or an increase in concentration of existing components. Added to this is the stimulating influence of the lens on vascular leakage leading to the influx of plasma proteins such as albumin. The evidence from studies of mucin expression in tears is not consistent and conclusive. This is in part because sample sources, lens materials and methods of analysis vary considerably, and in some cases the study population numbers are low. Expression levels show mucin and material specificity but clear patterns of behaviour are elusive. The electrolyte composition of tears is significantly different from that of other body fluids. Sodium and potassium dominate but potassium ion concentrations in tears are much higher than in serum levels. Calcium and magnesium concentrations in tears are lower than in serum but closer to interstitial fluids. The contact lens provides the potential for increased osmolarity through enhanced evaporation and differential electrolyte concentrations between the anterior and posterior tear films. Since the changes in ocular biochemistry consequent upon contact lens wear are known to be subject-dependent - as indeed is wearer response to the lens - pre-characterisation of individual participant tear chemistry in clinical studies would enhance understanding of these complex effects. © 2013 Elsevier Ltd.
Resumo:
Purpose: Polyvinyl alcohol (PVA) is a successful tear film stabiliser and is widely used in comfort drops and some soft contact lens materials. A PVA-containing lens, nelfilcon A has been modified to include additional (non-functional) PVA in order to provide improved comfort. This study aims to examine the clinical performance of this nelfilcon A lens with AquaRelease™ (AquaRelease). Methods: Two contralateral, investigator masked, open label, subjective and objective evaluations were conducted. The first examined the effect of adding increased molecular weight PVA to nelfilcon A (n = 5), and the second compared this AquaRelease lens to ocufilcon B (n = 34). The principal measures were non-invasive break-up time (NIBUT) and subjective comfort, which were assessed at the beginning and end of a week of daily wear, and three times throughout 1 day at 8, 12 and 16 h. Results: All subjects successfully completed the daily wearing schedule of 16 h. On initial insertion, subjective comfort and NIBUT improved for AquaRelease than original nelfilcon A lenses (p < 0.05). Initial comfort was better for AquaRelease compared to ocufilcon B lenses (p = 0.01); however, NIBUT was not statistically different (11.7 ± 15.6 s versus 8.4 ± 6.8 s; p = 0.26). Subjective comfort decreased with time (p < 0.001), but there was no significant difference between AquaRelease and ocufilcon B lenses (p = 0.16). NIBUT was not significantly affected by time (p = 0.56) or between lenses (p = 0.33). At the end of a weeks' wear, subjective initial, end-of-day, overall comfort and vision were rated significantly better with AquaRelease than ocufilcon B (p < 0.01). Conclusions: Release of additional non-functionalised PVA from the nelfilcon A lenses appears to enhance comfortable contact lens wear. © 2006 British Contact Lens Association.
Resumo:
The American Academy of Optometry (AAO) had their annual meeting in San Diego in December 2005 and the BCLA and CLAE were well represented there. The BCLA does have a reasonable number of non-UK based members and hopefully in the future will attract more. This will certainly be beneficial to the society as a whole and may draw more delegates to the BCLA annual conference. To increase awareness of the BCLA at the AAO a special evening seminar was arranged where BCLA president Dr. James Wolffsohn gave his presidential address. Dr. Wolffsohn has given the presidential address in the UK, Ireland, Hong Kong and Japan – making it the most travelled presidential address for the BCLA to date. Aside from the BCLA activity at the AAO there were numerous lectures of interest to all, truly a “something for everyone” meeting. All the sessions were multi-track (often up to 10 things occurring at the same time) and the biggest dilemma was often deciding what to attend and more importantly what you will miss! Nearly 200 new AAO Fellows were inducted at the Gala Dinner from many countries including 3 new fellows from the UK (this year they all just happened to be from Aston University!). It is certainly one of the highlights of the AAO to see fellows from different schools of training from around the world fulfilling the same criteria and being duly rewarded for their commitment to the profession. BCLA members will be aware that 2006 sees the introduction of the new fellowship scheme of the BCLA and by the time you read this the first set of fellowship examinations will have taken place. For more details of the FBCLA scheme see the BCLA web site http://www.bcla.org.uk. Since many of CLAE's editorial panel were at the AAO an informal meeting and dinner was arranged for them where ideas were exchanged about the future of the journal. It is envisaged that the panel will meet twice a year – the next meeting will be at the BCLA conference. The biggest excitement by far was the fact that CLAE is now Medline/PubMed indexed. You may ask why is this significant to CLAE? PubMed is the free web-based service from the US National Library of Medicine. It holds over 15 million biomedical citations and abstracts from the Medline database. Medline is the largest component of PubMed and covers over 4800 journals published in more than 70 countries. The impact of this is that CLAE is starting to attract more submissions as researchers and authors are not worried that their work will not be hidden from other colleagues in the field but rather the work is available to view on the World Wide Web. CLAE is one of a very small number of contact lens journals that is indexed this way. Amongst the other CL journals listed you will note that the International Contact Lens Clinic has now merged with CLAE and the journal CLAO has been renamed Eye and Contact Lenses – making the list of indexed CL journals even smaller than it appears. The on-line submission and reviewing system introduced in 2005 has also made it easier for authors to submit their work and easier for reviewers to check the content. This ease of use has lead to quicker times from submission to publication. Looking back at the articles published in CLAE in 2005 reveals some interesting facts. The majority of the material still tends to be from UK groups related to the field of Optometry, although we hope that in the future we will attract more work from non-UK groups and also from non-Optometric areas such as refractive surgery or anterior eye pathology. Interestingly in 2005 the most downloaded article from CLAE was “Wavefront technology: Past, present and future” by Professor W. Neil Charman, who was also the recipient of the Charles F. Prentice award at the AAO – one of the highest awards honours that the AAO can bestow. Professor Charman was also the keynote speaker at the BCLA's first Pioneer's Day meeting in 2004. In 2006, readers of CLAE will notice more changes, firstly we are moving to 5 issues per year. It is hoped that in the future, depending on increased submissions, a move to 6 issues may be feasible. Secondly, CLAE will aim to have one article per issue that carries CL CET points. You will see in this issue there is an article from Professor Mark Wilcox (who was a keynote speaker at the BCLA conference in 2005). In future articles that carry CET points will be either reviews from BCLA conference keynote speakers, members of the editorial panel or material from other invited persons that will be of interest to the readership of CLAE. Finally, in 2006, you will notice a change to the Editorial Panel, some of the distinguished panel felt that it was good time to step down and new members have been invited to join the remaining panel. The panel represent some of the most eminent names in the fields of contact lenses and/or anterior eye and have varying backgrounds and interests from many of the prominent institutions around the world. One of the tasks that the Editorial Panel undertake is to seek out possible submissions to the journal, either from conferences they attend (posters and papers that they will see and hear) and from their own research teams. However, on behalf of CLAE I would like to extend that invitation to seek original articles to all readers – if you hear a talk and think it could make a suitable publication to CLAE please ask the presenters to submit the work via the on-line submission system. If you found the work interesting then the chances are so will others. CLAE invites submissions that are original research, full length articles, short case reports, full review articles, technical reports and letters to the editor. The on-line submission web page is http://www.ees.elsevier.com/clae/.
Resumo:
Aim: To determine the dynamic emitted temperature changes of the anterior eye during and immediately after wearing different materials and modalities of soft contact lenses. Method: A dynamic, non-contact infrared camera (Thermo-Tracer TH7102MX, NEC San-ei) was used to record the ocular surface temperature (OST) in 48 subjects (mean age 21.7 ± 1.9 years) wearing: lotrafilcon-A contact lenses on a daily wear (LDW; n = 8) or continuous wear (LCW; n = 8) basis; balafilcon-A contact lenses on a daily wear (BDW; n = 8) or continuous wear (BCW; n = 8) basis; etafilcon-A contact lenses on a daily disposable regimen (EDW; n = 8); and no lenses (controls; n = 8). OST was measured continuously five times, for 8 s after a blink, following a minimum of 2 h wear and immediately following lens removal. Absolute temperature, changes in temperature post-blink and the dynamics of temperature changes were calculated. Results: OST immediately following contact lens wear was significantly greater compared to non-lens wearers (37.1 ± 1.7 °C versus 35.0 ± 1.1 °C; p < 0.005), predominantly in the LCW group (38.6 ± 1.0 °C; p < 0.0001). Lens surface temperature was highly correlated (r = 0.97) to, but lower than OST (by -0.62 ± 0.3 °C). There was no difference with modality of wear (DW 37.5 ± 1.6 °C versus CW 37.8 ± 1.9 °C; p = 0.63), but significant differences were found between etafilcon A and silicone hydrogel lens materials (35.3 ± 1.1 °C versus 37.5 ± 1.5 °C; p < 0.0005). Ocular surface cooling following a blink was not significantly affected by contact lens wear with (p = 0.07) or without (p = 0.47) lenses in situ. Conclusions: Ocular surface temperature is greater with hydrogel and greater still with silicone hydrogel contact lenses in situ, regardless of modality of wear. The effect is likely to be due to the thermal transmission properties of a contact lens. © 2004 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.
Resumo:
We design a Raman fibre laser with a short cavity providing narrow-band generation. The laser is based on a commercial single-mode fibre (980-HP) span of 12 m length. The laser generates up to 11 W of intracavity power. Even at high generation power, the laser spectrum is narrow (less than 200 pm) - several times narrower than for conventional Raman fibre lasers based on longer fibres. The intensity dynamics reveals indications of mode correlations. © 2014 Astro Ltd.
Resumo:
Lipids play a vital role in the body at many interfaces. Examples include the lubrication of articulating joints by synovial fluid, the coating of the lung by pulmonary surfactant and the functions of the tear film in the protection of the anterior eye. The role of the lipids is similar at each site - acting as boundary lubricants and reducing surface and interfacial tension. This review focuses on how and why contact lens wear can disrupt the normal function of lipids within the tear film and explains how the otherwise advantageous presence and function of tear lipids can become disadvantageous, causing problems for the wearer. Because the contact lens is some ten times thicker than the tear film, lipids deposited on the anterior surface become immobilised, reducing lipid turnover and thus leading to prolonged exposure to oxygen and light with consequent generation of degradation products. These degraded lipids reduce lens wettability and have additionally been linked to problems of contact lens discomfort and intolerance. Lipid problems are influenced by the thickness of the lens, the material, surface modification, mode of wear and ultimately the subject. The most influential of these variables is frequently the subject. © 2012.
Resumo:
Purpose: This work investigates how short-term changes in blood glucose concentration affect the refractive components of the diabetic eye in patients with long-term Type 1 and Type 2 diabetes. Methods: Blood glucose concentration, refractive error components (mean spherical equivalent MSE, J0, J45), central corneal thickness (CCT), anterior chamber depth (ACD), crystalline lens thickness (LT), axial length (AL) and ocular aberrations were monitored at two-hourly intervals over a 12-hour period in: 20 T1DM patients (mean age ± SD) 38±14 years, baseline HbA1c 8.6±1.9%; 21 T2DM patients (mean age ± SD) 56±11 years, HbA1c 7.5±1.8%; and in 20 control subjects (mean age ± SD) 49±23 years, HbA1c 5.5±0.5%. The refractive and biometric results were compared with the corresponding changes in blood glucose concentration. Results: Blood glucose concentration at different times was found to vary significantly within (p<0.0005) and between groups (p<0.0005). However, the refractive error components and ocular aberrations were not found to alter significantly over the day in either the diabetic patients or the control subjects (p>0.05). Minor changes of marginal statistical or optical significance were observed in some biometric parameters. Similarly there were some marginally significant differences between the baseline biometric parameters of well-controlled and poorly-controlled diabetic subjects. Conclusion: This work suggests that normal, short-term fluctuations (of up to about 6 mM/l on a timescale of a few hours) in the blood glucose levels of diabetics are not usually associated with acute changes in refractive error or ocular wavefront aberrations. It is therefore possible that factors other than refractive error fluctuations are sometimes responsible for the transient visual problems often reported by diabetic patients. © 2012 Huntjens et al.
Resumo:
PURPOSE: To assess the correlation between changes in corneal aberrations and the 2-year change in axial length in children fitted with orthokeratology (OK) contact lenses. METHODS: Thirty-one subjects 6 to 12 years of age and with myopia −0.75 to −4.00DS and astigmatism ≤1.00DC were fitted with OK. Measurements of axial length and corneal topography were taken at regular intervals over a 2-year period. Corneal topography at baseline and after 3 and 24 months of OK lens wear was used to derive higher-order corneal aberrations (HOA) that were correlated with OK-induced axial length changes at 2 years. RESULTS: Significant changes in C3, C4, C4, root mean square (RMS) secondary astigmatism and fourth and total HOA were found with both 3 and 24 months of OK lens wear in comparison with baseline (all P0.05). Coma angle of orientation changed significantly pre-OK in comparison with 3 and 24 months post-OK as well as secondary astigmatism angle of orientation pre-OK in comparison with 24 months post-OK (all P0.05). DISCUSSION: Short-term and long-term OK lens wear induces significant changes in corneal aberrations that are not significantly correlated with changes in axial elongation after 2-years.