22 resultados para Repeated Measures
Resumo:
Purpose: To compare lens orientation and rotational recovery of five currently available soft toric lenses. Methods: Twenty subjects were recruited and trialed with each of the study lenses in a random order. Study lenses were PureVision® Toric (B&L), Air Optix® for Astigmatism (Alcon), Biofinity® Toric (CooperVision), Acuvue® Advance for Astigmatism (Vistakon), and Proclear® Toric (CooperVision). Lens orientation in primary position to determine the lens rotation form the vertical position and rotational recovery to primary gaze orientation following a 45° manual misorientation for the different lenses was compared. Results: The Biofinity Toric showed the lowest rotation from the vertical position and the Proclear Toric the highest. Also, the highest and the lowest reorientation speed were related to the Biofinity Toric and the Acuvue Advance for Astigmatism, respectively. The Repeated Measures ANOVA showed a significant difference in the lens rotation (P=. 0.004) and rotational recovery (P<. 0.001) among different contact lenses and the performed multiple comparisons indicated differences in rotation and also in reorientation speed were only seen between the Biofinity Toric when compared to four other lenses (P<. 0.05). Conclusion: Although there was appropriate fitting, based upon lens orientation and reorientation speed, with each of the study lenses it would appear that the optimized ballast technique used in the design of the Biofinity Toric helps reduce lens rotation and improve rotational recovery compared to others.
Resumo:
Purpose: To explore the repeatability of lower-order and higher-order ocular aberrations measured in patients with keratoconus. Methods: The IRX-3 (Imagine Eyes, Paris, France) aberrometer was used to record lower-order and higher-order aberrations in 31 eyes of 31 patients with keratoconus. Four monocular measurements were taken consecutively for each patient. The aberrometry data were analysed up to the 5th Zernike order for a 4-mm pupil diameter. The data were evaluated using repeated-measures anova and Friedman analyses. Repeatability was analysed using within-subject standard deviation (SW) and the repeatability limit (r) calculated as 1.96 ×√2×Sw. Results: Of the 11 aberration terms evaluated, the repeatability of Z (2,0) (mean= 1.36μm; SW=0.09μm; r=0.26μm); Z (2,±2) RMS (mean=1.05μm; SW= 0.09μm; r=0.24μm) and Z (4,0) aberrations (mean=0.34μm; SW=0.09 μm; r=0.24μm) showed the highest variability. In contrast, Z (3,±1) RMS aberrations (mean=0.85μm; SW=0.06μm; r=0.16μm) and Z (4,±2) RMS aberrations (mean=0.40μm; SW=0.07μm; r=0.18μm) showed comparatively better repeatability. Conclusions: The lower-order and higher-order aberrations measured in this group of keratoconic patients showed higher levels of variability compared to previous investigations of visually-normal subjects. These results may be of interest to eyecare practitioners involved in the design and fitting of aberration-controlling contact lenses for patients with keratoconus. © 2011 The College of Optometrists.
Resumo:
Purpose: This paper aims to present a cross-national study that investigates changes in purchase intentions of UK versus Chinese consumers following exposure to successive e-WOM comments in the form of positive and negative user reviews for experience versus search products. Design/methodology/approach: A 2(e-WOM valence and order: negative versus positive most recent)×2(product type: experience versus search)×3(purchase intentions at t 1, t 2, t 3) repeated-measures factorial design is used to test a set of hypotheses developed from the literature. Findings: Chinese consumers are susceptible to recent e-WOM comments regardless of their valence, while UK consumers anchor on negative information regardless of the order in which it is acquired. This holds particularly for experience products. Originality/value: This cross-national study contributes to the scarce literature on the impact of e-WOM on consumer purchase decisions by comparing UK and Chinese consumers. The authors suggest that culture moderates the development of product evaluations following exposure to e-WOM. © Emerald Group Publishing Limited.
Resumo:
BACKGROUND: Contrast detection is an important aspect of the assessment of visual function; however, clinical tests evaluate limited spatial frequencies and contrasts. This study validates the accuracy and inter-test repeatability of a swept-frequency near and distance mobile app Aston contrast sensitivity test, which overcomes this limitation compared to traditional charts. METHOD: Twenty subjects wearing their full refractive correction underwent contrast sensitivity testing on the new near application (near app), distance app, CSV-1000 and Pelli-Robson charts with full correction and with vision degraded by 0.8 and 0.2 Bangerter degradation foils. In addition repeated measures using the 0.8 occluding foil were taken. RESULTS: The mobile apps (near more than distance, p = 0.005) recorded a higher contrast sensitivity than printed tests (p < 0.001); however, all charts showed a reduction in measured contrast sensitivity with degradation (p < 0.001) and a similar decrease with increasing spatial frequency (interaction > 0.05). Although the coefficient of repeatability was lowest for the Pelli-Robson charts (0.14 log units), the mobile app charts measured more spatial frequencies, took less time and were more repeatable (near: 0.26 to 0.37 log units; distance: 0.34 to 0.39 log units) than the CSV-1000 (0.30 to 0.93 log units). The duration to complete the CSV-1000 was 124 ± 37 seconds, Pelli-Robson 78 ± 27 seconds, near app 53 ± 15 seconds and distance app 107 ± 36 seconds. CONCLUSIONS: While there were differences between charts in contrast levels measured, the new Aston near and distance apps are valid, repeatable and time-efficient method of assessing contrast sensitivity at multiple spatial frequencies.
Resumo:
Anterior segment optical coherent tomography (AS-OCT, Visante; Zeiss) is used to examine meridional variation in anterior scleral thickness (AST) and its association with refractive error, ethnicity and gender. Scleral cross-sections of 74 individuals (28 males; 46 females; aged between 18-40 years (27.7±5.3)) were sampled twice in random order in 8 meridians: [superior (S), inferior (I), nasal (N), temporal (T), superior-temporal (ST), superior-nasal (SN), inferior-temporal (IT) and inferior-nasal (IN)]. AST was measured in 1mm anterior-toposterior increments (designated the A-P distance) from the scleral spur (SS) over a 6mm distance. Axial length and refractive error were measured with a Zeiss IOLMaster biometer and an open-view binocular Shin-Nippon autorefractor. Intra- And inter-observer variability of AST was assessed for each of the 8 meridians. Mixed repeated measures ANOVAs tested meridional and A-P distance differences in AST with refractive error, gender and ethnicity. Only right eye data were analysed. AST (mean±SD) across all meridians and A-P distances was 725±46μm. Meridian SN was the thinnest (662±57μm) and I the thickest (806 ±60μm). Significant differences were found between all meridians (p<0.001), except S:ST, IT:IN, IT:N and IN:N. Significant differences between A-P distances were found except between SS and 6 mm and between 2 and 4mm. AST measurements at 1mm (682±48 μm) were the thinnest and at 6mm (818±49 μm) the thickest (p<0.001); a significant interaction occurred between meridians and A-P distances (p<0.001). AST was significantly greater (p<0.001) in male subjects but no significant differences were found between refractive error or ethnicity. Significant variations in AST occur with regard to meridian and distance from the SS and may have utility in selecting optimum sites for pharmaceutical or surgical intervention.
Resumo:
Background and aims: The selective SGLT2 inhibitor dapagliflozin (DAPA) reduces hyperglycaemia independently of insulin secretion or action by inhibiting renal glucose reabsorption. This study (MB102014) is a randomised double-blind, placebo (PBO)-controlled trial of DAPA added to metformin (MET) in T2DM (n=546) inadequately controlled with MET alone. Previously reported short-term data at week 24 showed significant mean reductions in the primary [HbA1c] and secondary [fasting plasma glucose (FPG) and weight] endpoints with DAPA compared to PBO. Here we report efficacy and safety results at week 102 of the long-term extension. Materials and methods: Patients aged 18-77 years with HbA1c 7-10% received DAPA 2.5 mg, 5 mg, 10 mg or PBO, plus open-label MET (≥1500mg/d). Exploratory endpoints at week 102 included changes from baseline in HbA1c, FPG and weight, and were analyzed by longitudinal repeated measures analysis. Results: Overall 71.2% of patients completed 102 weeks of the study; fewer on PBO (63.5%) than on DAPA 2.5 mg, 5 mg, and 10 mg (68.3%, 73.0%, 79.8%), due mainly to more patients on PBO discontinuing for lack of efficacy. At week 102, all DAPA groups showed greater mean reductions from baseline in HbA1c, FPG and weight compared to PBO (table), effects that were similar to those observed at week 24 and maintained throughout the trial. More patients at week 102 also achieved a therapeutic response of HbA1c<7% with DAPA 2.5 mg, 5 mg, and 10 mg (20.7%, 26.4%, 31.5%) than with PBO (15.4%). Adverse events (AEs), serious AEs and AEs leading to discontinuation were balanced across all groups. Signs and symptoms suggestive of genital infection (GenInf) were reported in 11.7%, 14.6%, 12.6% (DAPA 2.5 mg, 5 mg, 10 mg) and 5.1% (PBO) of patients, with 1 discontinuation due to GenInf. Signs and symptoms suggestive of urinary tract infection (UTI) were reported in 8.0%, 8.8%, 13.3% (DAPA 2.5 mg, 5 mg, 10 mg) and 8.0% (PBO), with 1 discontinuation due to UTI. No event of pyelonephritis was reported. Conclusion: In comparison to PBO, DAPA added to MET over 102 weeks demonstrated greater and sustained improvements in glycaemic control, clinically meaningful reduction in weight, and no increased risk of hypoglycaemia in patients with T2DM inadequately controlled with MET alone.
Resumo:
Aim: Contrast sensitivity (CS) provides important information on visual function. This study aimed to assess differences in clinical expediency of the CS increment-matched new back-lit and original paper versions of the Melbourne Edge Test (MET) to determine the CS of the visually impaired. Methods: The back-lit and paper MET were administered to 75 visually impaired subjects (28-97 years). Two versions of the back-lit MET acetates were used to match the CS increments with the paper-based MET. Measures of CS were repeated after 30 min and again in the presence of a focal light source directed onto the MET. Visual acuity was measured with a Bailey-Lovie chart and subjects rated how much difficulty they had with face and vehicle recognition. Results: The back-lit MET gave a significantly higher CS than the paper-based version (14.2 ± 4.1 dB vs 11.3 ± 4.3 dB, p < 0.001). A significantly higher reading resulted with repetition of the paper-based MET (by 1.0 ± 1.7 dB, p < 0.001), but this was not evident with the back-lit MET (by 0.1 ± 1.4 dB, p = 0.53). The MET readings were increased by a focal light source, in both the back-lit (by 0.3 ± 0.81, p < 0.01) and paper-based (1.2 ± 1.7, p < 0.001) versions. CS as measured by the back-lit and paper-based versions of the MET was significantly correlated to patients' perceived ability to recognise faces (r = 0.71, r = 0.85 respectively; p < 0.001) and vehicles (r = 0.67, r = 0.82 respectively; p < 0.001), and with distance visual acuity (both r =-0.64; p < 0.001). Conclusions: The CS increment-matched back-lit MET gives higher CS values than the old paper-based test by approximately 3 dB and is more repeatable and less affected by external light sources. Clinically, the MET score provides information on patient difficulties with visual tasks, such as recognising faces. © 2005 The College of Optometrists.