27 resultados para Queensland University of Technology, Visual Arts
Resumo:
This thesis first considers the calibration and signal processing requirements of a neuromagnetometer for the measurement of human visual function. Gradiometer calibration using straight wire grids is examined and optimal grid configurations determined, given realistic constructional tolerances. Simulations show that for gradiometer balance of 1:104 and wire spacing error of 0.25mm the achievable calibration accuracy of gain is 0.3%, of position is 0.3mm and of orientation is 0.6°. Practical results with a 19-channel 2nd-order gradiometer based system exceed this performance. The real-time application of adaptive reference noise cancellation filtering to running-average evoked response data is examined. In the steady state, the filter can be assumed to be driven by a non-stationary step input arising at epoch boundaries. Based on empirical measures of this driving step an optimal progression for the filter time constant is proposed which improves upon fixed time constant filter performance. The incorporation of the time-derivatives of the reference channels was found to improve the performance of the adaptive filtering algorithm by 15-20% for unaveraged data, falling to 5% with averaging. The thesis concludes with a neuromagnetic investigation of evoked cortical responses to chromatic and luminance grating stimuli. The global magnetic field power of evoked responses to the onset of sinusoidal gratings was shown to have distinct chromatic and luminance sensitive components. Analysis of the results, using a single equivalent current dipole model, shows that these components arise from activity within two distinct cortical locations. Co-registration of the resulting current source localisations with MRI shows a chromatically responsive area lying along the midline within the calcarine fissure, possibly extending onto the lingual and cuneal gyri. It is postulated that this area is the human homologue of the primate cortical area V4.
Resumo:
It is known that parallel pathways exist within the visual system. These have been described as magnocellular and parvocellular as a result of the layered organisation of the lateral geniculate nucleus and extend from the retina to the cortex. Dopamine (DA) and acetylcholine (ACH) are neurotransmitters that are present in the visual pathway. DA is present in the retina and is associated with the interplexiform cells and horizontal cells. ACH is also present in the retina and is associated with displaced amacrine cells; it is also present in the superior colliculus. DA is found to be significantly depleted in the brain of Parkinson's disease (PD) patients and ACH in Alzheimer's disease (AD) patients. For this reason these diseases were used to assess the function of DA and ACH in the electrophysiology of the visual pathway. Experiments were conducted on young normals to design stimuli that would preferentially activate the magnocellular or parvocellular pathway. These stimuli were then used to evoke visual evoked potentials (VEP) in patients with PD and AD, in order to assess the function of DA and ACH in the visual pathway. Electroretinograms (ERGs) were also measured in PD patients to assess the role of DA in the retina. In addition, peripheral ACH function was assessed by measuring VEPs, ERGs and contrast sensitivity (CS) in young normals following the topical instillation of hyoscine hydrobromide (an anticholinergic drug). The results indicate that the magnocellular pathway can be divided into two: a cholinergic tectal-association area pathway carrying luminance information, and a non-cholinergic geniculo-cortical pathway carrying spatial information. It was also found that depletion of DA had very little effect on the VEPs or ERGs, confirming a general regulatory function for this neurotransmitter.
Resumo:
In an endeavour to provide further insight into the maturation of the human visual system, the contiguous development of the pattern reversal VEP, flash VEP and flash ERG was studied in a group of neurologically normal pre-term infants, born between 28 and 35 weeks gestation. Maturational changes were observed in all the evoked electrophysiological responses recorded, these were mainly characterised by an increase in the complexity of the waveform and a shortening in the latency of the response. Initially the ERG was seen to consist of a broad b-wave only, with the a-wave emerging at an average age of 40 weeks PMA. The a-wave showed only a slight reduction in latency and a modest increase in amplitude as the infant grows older, whereas the changes seen in the ERG b-wave were much more dramatic. Pattern reversal VEPs were successfully recorded for the first time during the pre-term period. Flash VEPs were also recorded for comparison. The neonatal pattern reversal VEP consistently showed a major positive component (P1) of long latency. As the infant grew older, the latency of the P1 component decreased and was found to be negatively correlated with PMA at recording. The appearance of the N1 and N2 components became more frequent as the infant matured. The majority of infants were found to be myopic at birth and refractive error was correlated with PMA, with emmetropisation occurring at about 45 weeks PMA. The pattern reversal VEP in response to 2o checks was apparently unaffected by refractive error.
Resumo:
Distortion or deprivation of vision during an early `critical' period of visual development can result in permanent visual impairment which indicates the need to identify and treat visually at-risk individuals early. A significant difficulty in this respect is that conventional, subjective methods of visual acuity determination are ineffective before approximately three years of age. In laboratory studies, infant visual function has been quantified precisely, using objective methods based on visual evoked potentials (VEP), preferential looking (PL) and optokinetic nystagmus (OKN) but clinical assessment of infant vision has presented a particular difficulty. An initial aim of this study was to evaluate the relative clinical merits of the three techniques. Clinical derivatives were devised, the OKN method proved unsuitable but the PL and VEP methods were evaluated in a pilot study. Most infants participating in the study had known ocular and/or neurological abnormalities but a few normals were included for comparison. The study suggested that the PL method was more clinically appropriate for the objective assessment of infant acuity. A study of normal visual development from birth to one year was subsequently conducted. Observations included cycloplegic refraction, ophthalmoscopy and preferential looking visual acuity assessment using horizontally and vertically oriented square wave gratings. The aims of the work were to investigate the efficiency and sensitivity of the technique and to study possible correlates of visual development. The success rate of the PL method varied with age; 87% of newborns and 98% of infants attending follow-up successfully completed at least one acuity test. Below two months monocular acuities were difficult to secure; infants were most testable around six months. The results produced were similar to published data using the acuity card procedure and slightly lower than, but comparable with acuity data derived using extended PL methods. Acuity development was not impaired in infants found to have retinal haemorrhages as newborns. A significant relationship was found between newborn binocular acuity and anisometropia but not with other refractive findings. No strong or consistent correlations between grating acuity and refraction were found for three, six or twelve months olds. Improvements in acuity and decreases in levels of hyperopia over the first week of life were suggestive of recovery from minor birth trauma. The refractive data was analysed separately to investigate the natural history of refraction in normal infants. Most newborns (80%) were hyperopic, significant astigmatism was found in 86% and significant anisometropia in 22%. No significant alteration in spherical equivalent refraction was noted between birth and three months, a significant reduction in hyperopia was evident by six months and this trend continued until one year. Observations on the astigmatic component of the refractive error revealed a rather erratic series of changes which would be worthy of further investigation since a repeat refraction study suggested difficulties in obtaining stable measurements in newborns. Astigmatism tended to decrease between birth and three months, increased significantly from three to six months and decreased significantly from six to twelve months. A constant decrease in the degree of anisometropia was evident throughout the first year. These findings have implications for the correction of infantile refractive error.
Resumo:
The topographical distribution of the pattern reversal Visual Evoked Response (VER) was recorded from a localised montage of 20 electrodes over the visual cortex. The response was recorded after stimulation with a black and white checkerboard stimulus. The effect of field location on the major components was investigated in 11 subjects (age range (23-55). The major components of the half field response were; a negative around 75ms (N75) followed by a positivity around 80ms (P80), then a positivity around 100ms (P100) followed by another positivity at around 120ms (P120) and a negativity at approximately 145ms (N145). No effect of field size could be demonstrated on either the amplitude or latency of the late negativity, N145. No significant effect of field size or location was shown on the latency of the P100 response. A delay previously shown in the upper half field response was therefore not substantiated. In contrast the amplitude of the major positivity, P100 was significantly affected by the field size and location. The amplitude of both P100 and N145 were significantly reduced following upper field stimulation when compared with the lower field response. No significant amplitude difference between the upper and lower field responses was demonstrated using electroretinography, the amplitude may therefore be reduced as a result of the ventral position of the upper field representation on the visual cortex. The lateral half field VEP was compared with the distribution of the visual evoked magnetic response (VEMR). The distribution of the VEMR supported the proposal that the paradoxical lateralisation of the VEP half field response is the result of the source being directed ipsilaterally. The morphology of the VEP following octant and double octant stimulation suggests that the response is generated in the striate cortex, with a reversal in response distribution following stimulation of the upper vertical and horizontal meridia.
Resumo:
The study investigated the potential applications and the limitations of non-standard techniques of visual field investigation utilizing automated perimetry. Normal subjects exhibited a greater sensitivity to kinetic stimuli than to static stimuli of identical size. The magnitude of physiological SKD was found to be largely independent of age, stimulus size, meridian and eccentricity. The absence of a dependency on stimulus size indicated that successive lateral spatial summation could not totally account for the underlying mechanism of physiological SKD. The visual field indices MD and LV exhibited a progressive deterioration during the time course of a conventional central visual field examination both for normal subjects and for ocular hypertensive patients. The fatigue effect was more pronounced in the latter stages and for the second eye tested. The confidence limits for the definition of abnormality should reflect the greater effect of fatigue on the second eye. A 330 cdm-2 yellow background was employed for blue-on-yellow perimetry. Instrument measurement range was preserved by positioning a concave mirror behind the stimulus bulb to increase the light output by 60% . The mean magnitude of SWS pathway isolation was approximately 1.4 log units relative to a 460nm stimulus filter. The absorption spectra of the ocular media exhibited an exponential increase with increase in age, whilst that of the macular pigment showed no systematic trend. The magnitude of ocular media absorption was demonstrated to reduce with increase in wavelength. Ocular media absorption was significantly greater in diabetic patients than in normal subjects. Five diabetic patients with either normal or borderline achromatic sensitivity exhibited an abnormal blue-on-yellow sensitivity; two of these patients showed no signs of retinopathy. A greater vulnerability of the SWS pathway to the diabetic disease process was hypothesized.
Resumo:
The diagnosis and monitoring of ocular disease presents considerable clinical difficulties for two main reasons i) the substantial physiological variation of anatomical structure of the visual pathway and ii) constraints due to technical limitations of diagnostic hardware. These are further confounded by difficulties in detecting early loss or change in visual function due to the masking of disease effects, for example, due to a high degree of redundancy in terms of nerve fibre number along the visual pathway. This thesis addresses these issues across three areas of study: 1. Factors influencing retinal thickness measures and their clinical interpretation As the retina is the principal anatomical site for damage associated with visual loss, objective measures of retinal thickness and retinal nerve fibre layer thickness are key to the detection of pathology. In this thesis the ability of optical coherence tomography (OCT) to provide repeatable and reproducible measures of retinal structure at the macula and optic nerve head is investigated. In addition, the normal physiological variations in retinal thickness and retinal nerve fibre layer thickness are explored. Principal findings were: • Macular retinal thickness and optic nerve head measurements are repeatable and reproducible for normal subjects and diseased eyes • Macular and retinal nerve fibre layer thickness around the optic nerve correlate negatively with axial length, suggesting that larger eyes have thinner retinae, potentially making them more susceptible to damage or disease • Foveola retinal thickness increases with age while retinal nerve fibre layer thickness around the optic nerve head decreases with age. Such findings should be considered during examination of the eye with suspect pathology or in long-term disease monitoring 2. Impact of glucose control on retinal anatomy and function in diabetes Diabetes is a major health concern in the UK and worldwide and diabetic retinopathy is a major cause of blindness in the working population. Objective, quantitative measurements of retinal thickness. particularly at the macula provide essential information regarding disease progression and the efficacy of treatment. Functional vision loss in diabetic patients is commonly observed in clinical and experimental studies and is thought to be affected by blood glucose levels. In the first study of its kind, the short term impact of fluctuations in blood glucose levels on retinal structure and function over a 12 hour period in patients with diabetes are investigated. Principal findings were: • Acute fluctuations in blood glucose levels are greater in diabetic patients than normal subjects • The fluctuations in blood glucose levels impact contrast sensitivity scores. SWAP visual fields, intraocular pressure and diastolic pressure. This effect is similar for type 1 and type 2 diabetic patients despite the differences in their physiological status. • Long-term metabolic control in the diabetic patient is a useful predictor in the fluctuation of contrast sensitivity scores. • Large fluctuations in blood glucose levels and/or visual function and structure may be indicative of an increased risk of development or progression of retinopathy 3. Structural and functional damage of the visual pathway in glaucomatous optic neuropathy The glaucomatous eye undergoes a number of well documented pathological changes including retinal nerve fibre loss and optic nerve head damage which is correlated with loss of functional vision. In experimental glaucoma there is evidence that glaucomatous damage extends from retinal ganglion cells in the eye, along the visual pathway, to vision centres in the brain. This thesis explores the effects of glaucoma on retinal nerve fibre layer thickness, ocular anterior anatomy and cortical structure, and its correlates with visual function in humans. Principal findings were: • In the retina, glaucomatous retinal nerve fibre layer loss is less marked with increasing distance from the optic nerve head, suggesting that RNFL examination at a greater distance than traditionally employed may provide invaluable early indicators of glaucomatous damage • Neuroretinal rim area and retrobulbar optic nerve diameter are strong indicators of visual field loss • Grey matter density decreases at a rate of 3.85% per decade. There was no clear evidence of a disease effect • Cortical activation as measured by fMRI was a strong indicator of functional damage in patients with significant neuroretinal rim loss despite relatively modest visual field defects These investigations have shown that the effects of senescence are evident in both the anterior and posterior visual pathway. A variety of anatomical and functional diagnostic protocols for the investigation of damage to the visual pathway in ocular disease are required to maximise understanding of the disease processes and thereby optimising patient care.
Resumo:
Extended Summary.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
The Product Service Systems, servitization, and Service Science literature continues to grow as organisations seek to protect and improve their competitive position. The potential of technology applications to deliver service delivery systems facilitated by the ability to make real time decisions based upon ‘in the field’ performance is also significant. Research identifies four key questions to be addressed. Namely: how far along the servitization continuum should the organisation go in a single strategic step? Does the organisation have the structure and infrastructure to support this transition? What level of condition monitoring should it employ? Is the product positioned correctly in the value chain to adopt condition monitoring technology? Strategy consists of three dimensions, namely content, context, and process. The literature relating to PSS, servitization, and strategy all discuss the concepts relative to content and context but none offer a process to deliver an aligned strategy to deliver a service delivery system enabled by condition based management. This paper presents a tested iterative strategy formulation methodology which is the result of a structured development programme.
Resumo:
This paper advances a philosophically informed rationale for the broader, reflexive and practical application of arts-based methods to benefit research, practice and pedagogy. It addresses the complexity and diversity of learning and knowing, foregrounding a cohabitative position and recognition of a plurality of research approaches, tailored and responsive to context. Appreciation of art and aesthetic experience is situated in the everyday, underpinned by multi-layered exemplars of pragmatic visual-arts narrative inquiry undertaken in the third, creative and communications sectors. Discussion considers semi-guided use of arts-based methods as a conduit for topic engagement, reflection and intersubjective agreement; alongside observation and interpretation of organically employed approaches used by participants within daily norms. Techniques span handcrafted (drawing), digital (photography), hybrid (cartooning), performance dimensions (improvised installations) and music (metaphor and structure). The process of creation, the artefact/outcome produced and experiences of consummation are all significant, with specific reflexivity impacts. Exploring methodology and epistemology, both the "doing" and its interpretation are explicated to inform method selection, replication, utility, evaluation and development of cross-media skills literacy. Approaches are found engaging, accessible and empowering, with nuanced capabilities to alter relationships with phenomena, experiences and people. By building a discursive space that reduces barriers; emancipation, interaction, polyphony, letting-go and the progressive unfolding of thoughts are supported, benefiting ways of knowing, narrative (re)construction, sensory perception and capacities to act. This can also present underexplored researcher risks in respect to emotion work, self-disclosure, identity and agenda. The paper therefore elucidates complex, intricate relationships between form and content, the represented and the representation or performance, researcher and participant, and the self and other. This benefits understanding of phenomena including personal experience, sensitive issues, empowerment, identity, transition and liminality. Observations are relevant to qualitative and mixed methods researchers and a multidisciplinary audience, with explicit identification of challenges, opportunities and implications.
Resumo:
Technology discloses man’s mode of dealing with Nature, the process of production by which he sustains his life, and thereby also lays bare the mode of formation of his social relations, and of the mental conceptions that flow from them (Marx, 1990: 372) My thesis is a Sociological analysis of UK policy discourse for educational technology during the last 15 years. My framework is a dialogue between the Marxist-based critical social theory of Lieras and a corpus-based Critical Discourse Analysis (CDA) of UK policy for Technology Enhanced Learning (TEL) in higher education. Embedded in TEL is a presupposition: a deterministic assumption that technology has enhanced learning. This conceals a necessary debate that reminds us it is humans that design learning, not technology. By omitting people, TEL provides a vehicle for strong hierarchical or neoliberal, agendas to make simplified claims politically, in the name of technology. My research has two main aims: firstly, I share a replicable, mixed methodological approach for linguistic analysis of the political discourse of TEL. Quantitatively, I examine patterns in my corpus to question forms of ‘use’ around technology that structure a rigid basic argument which ‘enframes’ educational technology (Heidegger, 1977: 38). In a qualitative analysis of findings, I ask to what extent policy discourse evaluates technology in one way, to support a Knowledge Based Economy (KBE) in a political economy of neoliberalism (Jessop 2004, Fairclough 2006). If technology is commodified as an external enhancement, it is expected to provide an ‘exchange value’ for learners (Marx, 1867). I therefore examine more closely what is prioritised and devalued in these texts. Secondly, I disclose a form of austerity in the discourse where technology, as an abstract force, undertakes tasks usually ascribed to humans (Lieras, 1996, Brey, 2003:2). This risks desubjectivisation, loss of power and limits people’s relationships with technology and with each other. A view of technology in political discourse as complete without people closes possibilities for broader dialectical (Fairclough, 2001, 2007) and ‘convivial’ (Illich, 1973) understandings of the intimate, material practice of engaging with technology in education. In opening the ‘black box’ of TEL via CDA I reveal talking points that are otherwise concealed. This allows me as to be reflexive and self-critical through praxis, to confront my own assumptions about what the discourse conceals and what forms of resistance might be required. In so doing, I contribute to ongoing debates about networked learning, providing a context to explore educational technology as a technology, language and learning nexus.