PMMA based polymer optical fibre Bragg gratings have been used for humidity, temperature and concentration sensing. Due to the water affinity of PMMA, the characteristic wavelength of the grating is largely modulated by the water content in the fibre. The rate of water transportation between fibre and surrounding depends on the permeability coefficient for PMMA, which is a function of surrounding temperature and humidity. This leads to increased water content with increasing humidity and temperature. Consequently the wavelength of the grating shows a nonlinear change over varying humidity and temperature. This nonlinearity needs to be calibrated prior to sensor application.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present an optical bend sensor based on a Bragg grating written in an eccentric core polymer optical fibre. The grating wavelength shifts are studied as a function of bend curvature and fibre orientation and the device exhibits strong fibre orientation dependence, wide bend curvature range of ± 22.7 m-1 and high bend sensitivity of 63 pm/m-1, which is 80 times higher than the reported sensor based on an offset-FBG in standard single mode silica fibre.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We describe recent research into devices based on fibre Bragg gratings in polymer optical fibre. Firstly, we report on the inscription of gratings in a variety of microstructured polymer optical fibre: single mode, few moded and multimoded, as well as fibre doped with trans-4-stilbenmethanol. Secondly, we describe research into an electrically tuneable filter using a metallic coating on a polymer fibre Bragg grating. Finally we present initial results from attempts to produce more complex grating structures in polymer fibre: a Fabry-Perot cavity and a phase-shifted grating.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The reaction of btzmp (1,2-bis(tetrazol-1-yl)-2-methylpropane) with Fe(ClO4)2 generates a 1D polymeric species, [Fe(μ-btzmp)2(btzmp)2](ClO4)2, showing a steep spin transition (T½↑ = 136 K and T ½↓ = 133 K) with a 3 K thermal hysteresis. The crystal structure at 100 and 200 K reveals that, in contrast to other bistetrazole based spin-transition systems such as [Fe(endi)3](BF4)2 and [Fe(btzp)3](ClO4)2, the present compound has only two ligands bridging the metallic centres, while the other two coordination positions are occupied by two mono-coordinated (non-bridging) btzmp ligands. This peculiarity confers an unprecedented crystal packing in the series of 1D bistetrazole based polymers. The change in spin state is accompanied by an order/disorder transition of the ClO4- counterion. A careful examination of the structural changes occurring upon the spin transition indicates that this order/disorder is most likely affected by the modification of the [tetrazole-centroid]-ND-Fe angle (which is typical of bistetrazole spin-transition materials). Apart from X-ray analysis, also magnetic susceptibility, Mössbauer and UV-vis spectroscopies have been used to characterise the HS and the LS states of [Fe(µ-btzmp)2(btzmp)2](ClO4)2. © The Royal Society of Chemistry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple, low cost and fast response time intrinsic relative humidity sensor system based on an etched singlemode polymer fiber Bragg (POFBG) is presented in this paper. A macro-bend linear edge filter which converts the humidity induced wavelength shift into an intensity change is used as the interrogation technique. The singlemode POFBG is etched to micro-meters in diameter to improve the response time of the humidity sensor. A response time of 4.5 s is observed for a polymer FBG with a cladding diameter of 25 μm. The overall sensor system sensitivity was 0.23 mV/%RH. The etched POFBG humidity sensor shows anexponential decrease in response time with a decrease in fiber diameter. The developed sensor might have potential applications in a wide range of applications where fast and accurate real time humidity control is required. © 2013 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pyrolytic recycling of materials for electronics and automotive is attractive because of the possibility of recovery of fuel and of precious metals from printed circuit. Due to the complexity of their composition an appropriate pre-treatment has to be performed in order to limit the evolution of dangerous halogen containing compounds which strongly impair the fuel quality. An advantageous pyrolysis approach implies the attempt of mineralisation of the organic bromine to the not volatile and harmless inorganic form using strong bases such as NaOH and KOH to reduce the amount of volatile and increasing the residue. The char stability is greatly variable depending on the substrate. Mg(OH)2 and Ca(OH)2 behave in a similar manner but to a lower extent. Carbonates and reducing agent such as LiAlH have been tested as well and their ability to scavenge bromine is discussed in terms of effectiveness and mechanism.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper we investigate the effects of viscoelasticity on both the strength and resonance wavelength of two fibre Bragg gratings (FBGs) inscribed in microstructured polymer optical fibre (mPOF) made of undoped PMMA. Both FBGs were inscribed under a strain of 1% in order to increase the material photosensitivity. After the inscription the strain was released and the FBGs spectra were monitored. We initially observed a decrease of the reflection down to zero after which it began to increase. After that, strain tests were carried out to confirm the results and finally the gratings were monitored for a further 120 days, with a stable reflection response being observed beyond 50 days.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose a remotely tuneable optical Bragg grating filter written in polymer optical fibre (POF). Fibre optical pumping in the fibre's absorption bands increases the fibre temperature, which causes a negative wavelength change of the POF Bragg grating. By choosing a proper pumping wavelength remote tuning of the optical filter can be readily realized without changing the gain of the optical signal.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A numerical model for studying the performance of polymer optical fibre-based interferometric sensors is presented. The strain sensitivity of Fabry-Perot and two-beam interferometric sensors is investigated by varying the physical and optical properties corresponding to frequently used wavelengths. The developed model was used to identify the regimes in which these devices offer enhanced performance over their silica counterparts when used for stress sensing. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Liquid-level sensing technologies have attracted great prominence, because such measurements are essential to industrial applications, such as fuel storage, flood warning and in the biochemical industry. Traditional liquid level sensors are based on electromechanical techniques; however they suffer from intrinsic safety concerns in explosive environments. In recent years, given that optical fiber sensors have lots of well-established advantages such as high accuracy, costeffectiveness, compact size, and ease of multiplexing, several optical fiber liquid level sensors have been investigated which are based on different operating principles such as side-polishing the cladding and a portion of core, using a spiral side-emitting optical fiber or using silica fiber gratings. The present work proposes a novel and highly sensitive liquid level sensor making use of polymer optical fiber Bragg gratings (POFBGs). The key elements of the system are a set of POFBGs embedded in silicone rubber diaphragms. This is a new development building on the idea of determining liquid level by measuring the pressure at the bottom of a liquid container, however it has a number of critical advantages. The system features several FBG-based pressure sensors as described above placed at different depths. Any sensor above the surface of the liquid will read the same ambient pressure. Sensors below the surface of the liquid will read pressures that increase linearly with depth. The position of the liquid surface can therefore be approximately identified as lying between the first sensor to read an above-ambient pressure and the next higher sensor. This level of precision would not in general be sufficient for most liquid level monitoring applications; however a much more precise determination of liquid level can be made by linear regression to the pressure readings from the sub-surface sensors. There are numerous advantages to this multi-sensor approach. First, the use of linear regression using multiple sensors is inherently more accurate than using a single pressure reading to estimate depth. Second, common mode temperature induced wavelength shifts in the individual sensors are automatically compensated. Thirdly, temperature induced changes in the sensor pressure sensitivity are also compensated. Fourthly, the approach provides the possibility to detect and compensate for malfunctioning sensors. Finally, the system is immune to changes in the density of the monitored fluid and even to changes in the effective force of gravity, as might be obtained in an aerospace application. The performance of an individual sensor was characterized and displays a sensitivity (54 pm/cm), enhanced by more than a factor of 2 when compared to a sensor head configuration based on a silica FBG published in the literature, resulting from the much lower elastic modulus of POF. Furthermore, the temperature/humidity behavior and measurement resolution were also studied in detail. The proposed configuration also displays a highly linear response, high resolution and good repeatability. The results suggest the new configuration can be a useful tool in many different applications, such as aircraft fuel monitoring, and biochemical and environmental sensing, where accuracy and stability are fundamental. © (2015) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Graphene-based silica fiber-optic sensors, with high sensitivity, fast response, and low cost, have shown great promise for gas sensing applications. In this letter, by covering a monolayer of p-doped graphene on a D-shaped microstructured polymer fiber Bragg grating (FBG), we propose and demonstrate a novel biochemical probe sensor, the graphene-based D-shaped polymer FBG (GDPFBG). Due to the graphene-based surface evanescent field enhancement, this sensor shows high sensitivity to detect surrounding biochemical parameters. By monitoring the Bragg peak locations of the GDPFBG online, human erythrocyte (red blood cell) solutions with different cellular concentrations ranging from 0 to 104 ppm were detected precisely, with the maximum resolution of sub-ppm. Such a sensor is structurally compact, is clinically acceptable, and provides good recoverability, offering a state-of-the-art polymer-fiber-based sensing platform for highly sensitive in situ and in vivo cell detection applications.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The stress sensitivity of polymer optical fibre (POF) based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions is investigated. POF has received high interest in recent years due to its different material properties compared to its silica counterpart. Biocompatibility, a higher failure strain and the highly elastic nature of POF are some of the main advantages. The much lower Young’s modulus of polymer materials compared to silica offers enhanced stress sensitivity to POF based sensors which renders them great candidates for acoustic wave receivers and any kind of force detection. The main drawback in POF technology is perhaps the high fibre loss. In a lossless fibre the sensitivity of an interferometer is proportional to its cavity length. However, the presence of the attenuation along the optical path can significantly reduce the finesse of the Fabry-Perot interferometer and it can negatively affect its sensitivity at some point. The reflectivity of the two gratings used to form the interferometer can be also reduced as the fibre loss increases. In this work, a numerical model is developed to study the performance of POF based Fabry-Perot sensors formed by two uniform Bragg gratings with finite dimensions. Various optical and physical properties are considered such as grating physical length, grating effective length which indicates the point where the light is effectively reflected, refractive index modulation of the grating, cavity length of the interferometer, attenuation and operating wavelength. Using this model, we are able to identify the regimes in which the PMMA based sensor offer enhanced stress sensitivity compared to silica based one.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The annealing effects on strain and stress sensitivity of polymer optical fibre Bragg grating sensors after their photo-inscription are investigated. PMMA optical fibre based Bragg grating sensors are first photo-inscribed and then they were placed into hot water for annealing. Strain, stress and force sensitivity measurements are taken before and after annealing. Parameters such as annealing time and annealing temperature are investigated. The change of the fibre diameter due to water absorption and the annealing process is also considered. The results show that annealing the polymer optical fibre tends to increase the strain, stress and force sensitivity of the photo-inscribed sensor.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

By covering a monolayer of p-doped graphene on a D-shaped microstructured FBG, a graphene based D-shaped polymer fiber Bragg grating is proposed to detect human erythrocytes, with clinic acceptability and high sensitivity of sub ppm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thermal annealing can be used to induce a permanent negative Bragg wavelength shift for polymer fibre grating sensors and it was originally used for multiplexing purposes. Recently, researchers showed that annealing can also provide additional benefits, such as strain and humidity sensitivity enhancement and augmented temperature operational range. The annealing process can change both the optical and mechanical properties of the fibre. In this paper, the annealing effects on the stress and force sensitivities of PMMA fibre Bragg grating sensors are investigated. The incentive for that investigation was an unexpected behaviour observed in an array of sensors which were used for liquid level monitoring. One sensor exhibited much lower pressure sensitivity and that was the only one that was not annealed. To further investigate the phenomenon, additional sensors were photo-inscribed and characterised with regard their stress and force sensitivities. Then, the fibres were annealed by placing them in hot water, controlling with that way the humidity factor. After annealing, stress and force sensitivities were measured again. The results show that the annealing can improve the stress and force sensitivity of the devices. This can provide better performing sensors for use in stress, force and pressure sensing applications.