26 resultados para Patient Activation Measure 13


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: Recently, pattern recognition approaches have been used to classify patterns of brain activity elicited by sensory or cognitive processes. In the clinical context, these approaches have been mainly applied to classify groups of individuals based on structural magnetic resonance imaging (MRI) data. Only a few studies have applied similar methods to functional MRI (fMRI) data. Methods: We used a novel analytic framework to examine the extent to which unipolar and bipolar depressed individuals differed on discrimination between patterns of neural activity for happy and neutral faces. We used data from 18 currently depressed individuals with bipolar I disorder (BD) and 18 currently depressed individuals with recurrent unipolar depression (UD), matched on depression severity, age, and illness duration, and 18 age- and gender ratio-matched healthy comparison subjects (HC). fMRI data were analyzed using a general linear model and Gaussian process classifiers. Results: The accuracy for discriminating between patterns of neural activity for happy versus neutral faces overall was lower in both patient groups relative to HC. The predictive probabilities for intense and mild happy faces were higher in HC than in BD, and for mild happy faces were higher in HC than UD (all p < 0.001). Interestingly, the predictive probability for intense happy faces was significantly higher in UD than BD (p = 0.03). Conclusions: These results indicate that patterns of whole-brain neural activity to intense happy faces were significantly less distinct from those for neutral faces in BD than in either HC or UD. These findings indicate that pattern recognition approaches can be used to identify abnormal brain activity patterns in patient populations and have promising clinical utility as techniques that can help to discriminate between patients with different psychiatric illnesses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The calcitonin gene-related peptide (CGRP) receptor is a complex of a cal-citonin receptor-like receptor (CLR), which is a family B G-protein-coupled receptor (GPCR) and receptor activity modifying protein 1. The role of the second extracellular loop (ECL2) of CLR in binding CGRP and coupling to Gs was investigated using a combination of mutagenesis and modelling. An alanine scan of residues 271-294 of CLR showed that the ability of CGRP to produce cAMP was impaired by point mutations at 13 residues; most of these also impaired the response to adrenomedullin (AM). These data were used to select probable ECL2-modelled conformations that are involved in agonist binding, allowing the identification of the likely contacts between the peptide and receptor. The implications of the most likely structures for receptor activation are discussed. © 2013 The Authors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: Menorrhagia is a common problem that interferes with a woman’s physical, emotional, and social life. Evidence to guide physicians for decision about therapy for heavy menstrual bleeding is lacking. One treatment option, the levonorgestrel-releasing intrauterine system (levonorgestrel-IUS), has been available in the United States since 2009. Updated meta-analyses comparing the levonorgestrel-IUS with nonhormonal and hormonal treatments showed that the levonorgestrel-IUS produced a greater reduction in menstrual blood loss at 3 to 12 months of follow-up. It is not clear whether these short-term benefits persist. Moreover, the rates of discontinuation of the levonorgestrel-IUS at 2 years are as high as 28%, and effects on bleeding-related quality of life are not known. This pragmatic, multicenter, randomized trial compared the effectiveness of the levonorgestrel-IUS with that of usual medical treatment among women with menorrhagia in a primary care setting. A total of 571 women with menorrhagia were randomized to treatment with levonorgestrel-IUS (n = 285) or usual medical treatment (n = 286). Usual treatment was tranexamic acid, mefenamic acid, combined estrogen-progestogen, or progesterone alone. The primary study outcome measure was the patient-reported score on the condition-specific Menorrhagia Multi-Attribute Scale (MMAS) assessed over a 2-year period. The MMAS scores range from 0 to 100, with lower scores indicating greater severity. Summary MMAS scores were assessed at 6, 12, and 24 months. Secondary outcome measures included general health-related quality of life, sexual-activity scores, and surgical intervention. There was a significant improvement in total MMAS scores from baseline to 6 months in both the levonorgestrel-IUS group and the usual-treatment group; the mean increase was 32.7 and 21.4 points, respectively; P < 0.001 for both comparisons. Over the 2-year follow-up, improvements were maintained in both groups but were significantly greater in the levonorgestrel-IUS group (mean between-group difference, 13.4 points; 95% confidence interval, 9.9–16.9; P < 0.001). Significantly greater improvements in all MMAS domains (practical difficulties, social life, psychological health, physical health, work and daily routine, and family life and relationships) occurred with the levonorgestrel-IUS than with the usual treatment (P < 0.001 with the use of a test for trend). This was also found for 7 of the 8 quality-of-life domains. At the 2-year end point, almost twice as many women were still using the levonorgestrel-IUS than were those receiving the usual medical treatment (64% vs 38%, P < 0.001). No significant between-group differences were noted in the rates of surgical intervention or sexual-activity scores as well as in the frequency of serious adverse events. These data show that levonorgestrel-IUS is more effective than usual medical treatment in improving the quality of life of women with menorrhagia in a primary care setting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To conduct an independent evaluation of the first phase of the Health Foundation's Safer Patients Initiative (SPI), and to identify the net additional effect of SPI and any differences in changes in participating and non-participating NHS hospitals. Design: Mixed method evaluation involving five substudies, before and after design. Setting: NHS hospitals in United Kingdom. Participants: Four hospitals (one in each country in the UK) participating in the first phase of the SPI (SPI1); 18 control hospitals. Intervention: The SPI1 was a compound (multicomponent) organisational intervention delivered over 18 months that focused on improving the reliability of specific frontline care processes in designated clinical specialties and promoting organisational and cultural change. Results: Senior staff members were knowledgeable and enthusiastic about SPI1. There was a small (0.08 points on a 5 point scale) but significant (P<0.01) effect in favour of the SPI1 hospitals in one of 11 dimensions of the staff questionnaire (organisational climate). Qualitative evidence showed only modest penetration of SPI1 at medical ward level. Although SPI1 was designed to engage staff from the bottom up, it did not usually feel like this to those working on the wards, and questions about legitimacy of some aspects of SPI1 were raised. Of the five components to identify patients at risk of deterioration - monitoring of vital signs (14 items); routine tests (three items); evidence based standards specific to certain diseases (three items); prescribing errors (multiple items from the British National Formulary); and medical history taking (11 items) - there was little net difference between control and SPI1 hospitals, except in relation to quality of monitoring of acute medical patients, which improved on average over time across all hospitals. Recording of respiratory rate increased to a greater degree in SPI1 than in control hospitals; in the second six hours after admission recording increased from 40% (93) to 69% (165) in control hospitals and from 37% (141) to 78% (296) in SPI1 hospitals (odds ratio for "difference in difference" 2.1, 99% confidence interval 1.0 to 4.3; P=0.008). Use of a formal scoring system for patients with pneumonia also increased over time (from 2% (102) to 23% (111) in control hospitals and from 2% (170) to 9% (189) in SPI1 hospitals), which favoured controls and was not significant (0.3, 0.02 to 3.4; P=0.173). There were no improvements in the proportion of prescription errors and no effects that could be attributed to SPI1 in non-targeted generic areas (such as enhanced safety culture). On some measures, the lack of effect could be because compliance was already high at baseline (such as use of steroids in over 85% of cases where indicated), but even when there was more room for improvement (such as in quality of medical history taking), there was no significant additional net effect of SPI1. There were no changes over time or between control and SPI1 hospitals in errors or rates of adverse events in patients in medical wards. Mortality increased from 11% (27) to 16% (39) among controls and decreased from17%(63) to13%(49) among SPI1 hospitals, but the risk adjusted difference was not significant (0.5, 0.2 to 1.4; P=0.085). Poor care was a contributing factor in four of the 178 deaths identified by review of case notes. The survey of patients showed no significant differences apart from an increase in perception of cleanliness in favour of SPI1 hospitals. Conclusions The introduction of SPI1 was associated with improvements in one of the types of clinical process studied (monitoring of vital signs) and one measure of staff perceptions of organisational climate. There was no additional effect of SPI1 on other targeted issues nor on other measures of generic organisational strengthening.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hospitals everywhere are integrating health data using electronic health record (EHR) systems, and disparate and multimedia patient data can be input by different caregivers at different locations as encapsulated patient profiles. Healthcare institutions are also using the flexibility and speed of wireless computing to improve quality and reduce costs. We are developing a mobile application that allows doctors to efficiently record and access complete and accurate real-time patient information. The system integrates medical imagery with textual patient profiles as well as expert interactions by healthcare personnel using knowledge management and case-based reasoning techniques. The application can assist other caregivers in searching large repositories of previous patient cases. Patients' symptoms can be input to a portable device and the application can quickly retrieve similar profiles which can be used to support effective diagnoses and prognoses by comparing symptoms, treatments, diagnosis, test results and other patient information. © 2007 Sage Publications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Patient-reported outcome measures (PROMs) are measures of the outcome of treatment(s) reported directly by the patient or carer. There is increasing international policy interest in using these to assess the impact of clinical care. AIMS: To identify suitably validated PROMs for asthma and examine their potential for use in clinical settings. METHODS: We systematically searched MEDLINE, EMBASE and Web of Science databases from 1990 onwards to identify PROMs for asthma. These were critically appraised, then narratively synthesised. We also identified the generic PROMs commonly used alongside asthma-specific PROMs. RESULTS: We identifi ed 68 PROMs for asthma, 13 of which were selected through screening as being adequately developed to warrant full-quality appraisal: 8 for adults, 4 for children and 1 for a child's caregiver. The PROMs found to be sufficiently well validated to offer promise for use in clinical settings were the Asthma Quality of Life Questionnaire (AQLQ) and mini-AQLQ for adults, and Pediatric Asthma Quality of Life Questionnaire for children. Rhinasthma was considered promising in simultaneously assessing the impact of asthma and rhinitis in those with coexistent disease. We identified 28 generic PROMs commonly used in conjunction with asthma-specific instruments. CONCLUSIONS: We identified asthma PROMs that offer the greatest potential for use in clinical settings. Further work is needed to assess whether these are fit-for-purpose for use in clinical practice with individual patients. In particular, there is a need to ensure these are validated for use in clinical settings, acceptable to patients, caregivers and clinicians, and yield meaningful outcomes. © 2014 Primary Care Respiratory Society/Macmillan Publishers Limited.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 ± 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was -0.13 ± 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of ±0.50 D. Mean uncorrected distance visual acuity was +0.10 ± 0.12 logMAR monocularly and 0.02 ± 0.09 logMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 ± 0.16 logMAR, improving to 0.15 ± 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 ± 0.11 logMAR, improving to 0.09 ± 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 ± 0.14 log units at 3 cycles per degree, 1.88 ± 0.20 log units at 6 cycles per degree, 1.66 ± 0.19 log units at 12 cycles per degree, and 1.11 ± 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 1° of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 ± 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision. © SLACK Incorporated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Systemic hypertension is an important public health concern. If optometrists are to perform a more active role in the detection and monitoring of high blood pressure (BP), there is a need to improve the consistency of describing the retinal vasculature and to assess patient's ability to correctly report the diagnosis of hypertension, its control and medication. One hundred and one patients aged >40 years were dilated and had fundus photography performed. BP was measured and a self-reported history of general health and current medication was compared with the records of their general practitioner (GP). The status of the retinal vasculature was quantified using a numeric scale by five clinicians and this was compared to the same evaluation performed with the aid of a basic pictorial grading scale. Image analysis was used to objectively measure the artery-to-vein (A/V) ratio and arterial reflex. Arteriolar tortuosity and calibre changes were found to be the most sensitive retinal signs of high BP. Using the grading scale to describe the retinal vasculature significantly improved inter- and intra-observer repeatability. Almost half the patients examined were on medication for high BP or cardiovascular disease. Patients' ability to give their complete medical history was poor, as was their ability to recall what medication they had been prescribed. GPs indicated it was useful to receive details of their patient's BP when it was >140/90 mmHg. The use of improved description of the retinal vasculature and stronger links between optometrists and GPs may enhance future patient care. © 2001 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe the case of a dysgraphic aphasic individual-S.G.W.-who, in writing to dictation, produced high rates of formally related errors consisting of both lexical substitutions and what we call morphological-compound errors involving legal or illegal combinations of morphemes. These errors were produced in the context of a minimal number of semantic errors. We could exclude problems with phonological discrimination and phonological short-term memory. We also excluded rapid decay of lexical information and/or weak activation of word forms and letter representations since S.G.W.'s spelling showed no effect of delay and no consistent length effects, but, instead, paradoxical complexity effects with segmental, lexical, and morphological errors that were more complex than the target. The case of S.G.W. strongly resembles that of another dysgraphic individual reported in the literature-D.W.-suggesting that this pattern of errors can be replicated across patients. In particular, both patients show unusual errors resulting in the production of neologistic compounds (e.g., "bed button" in response to "bed"). These patterns can be explained if we accept two claims: (a) Brain damage can produce both a reduction and an increase in lexical activation; and (b) there are direct connections between phonological and orthographic lexical representations (a third spelling route). We suggest that both patients are suffering from a difficulty of lexical selection resulting from excessive activation of formally related lexical representations. This hypothesis is strongly supported by S.G.W.'s worse performance in spelling to dictation than in written naming, which shows that a phonological input, activating a cohort of formally related lexical representations, increases selection difficulties. © 2014 Taylor & Francis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Bladder cancer is among the most common cancers in the UK and conventional detection techniques suffer from low sensitivity, low specificity, or both. Recent attempts to address the disparity have led to progress in the field of autofluorescence as a means to diagnose the disease with high efficiency, however there is still a lot not known about autofluorescence profiles in the disease. The multi-functional diagnostic system "LAKK-M" was used to assess autofluorescence profiles of healthy and cancerous bladder tissue to identify novel biomarkers of the disease. Statistically significant differences were observed in the optical redox ratio (a measure of tissue metabolic activity), the amplitude of endogenous porphyrins and the NADH/porphyrin ratio between tissue types. These findings could advance understanding of bladder cancer and aid in the development of new techniques for detection and surveillance.