30 resultados para Objective measures
Resumo:
The diagnosis and monitoring of ocular disease presents considerable clinical difficulties for two main reasons i) the substantial physiological variation of anatomical structure of the visual pathway and ii) constraints due to technical limitations of diagnostic hardware. These are further confounded by difficulties in detecting early loss or change in visual function due to the masking of disease effects, for example, due to a high degree of redundancy in terms of nerve fibre number along the visual pathway. This thesis addresses these issues across three areas of study: 1. Factors influencing retinal thickness measures and their clinical interpretation As the retina is the principal anatomical site for damage associated with visual loss, objective measures of retinal thickness and retinal nerve fibre layer thickness are key to the detection of pathology. In this thesis the ability of optical coherence tomography (OCT) to provide repeatable and reproducible measures of retinal structure at the macula and optic nerve head is investigated. In addition, the normal physiological variations in retinal thickness and retinal nerve fibre layer thickness are explored. Principal findings were: • Macular retinal thickness and optic nerve head measurements are repeatable and reproducible for normal subjects and diseased eyes • Macular and retinal nerve fibre layer thickness around the optic nerve correlate negatively with axial length, suggesting that larger eyes have thinner retinae, potentially making them more susceptible to damage or disease • Foveola retinal thickness increases with age while retinal nerve fibre layer thickness around the optic nerve head decreases with age. Such findings should be considered during examination of the eye with suspect pathology or in long-term disease monitoring 2. Impact of glucose control on retinal anatomy and function in diabetes Diabetes is a major health concern in the UK and worldwide and diabetic retinopathy is a major cause of blindness in the working population. Objective, quantitative measurements of retinal thickness. particularly at the macula provide essential information regarding disease progression and the efficacy of treatment. Functional vision loss in diabetic patients is commonly observed in clinical and experimental studies and is thought to be affected by blood glucose levels. In the first study of its kind, the short term impact of fluctuations in blood glucose levels on retinal structure and function over a 12 hour period in patients with diabetes are investigated. Principal findings were: • Acute fluctuations in blood glucose levels are greater in diabetic patients than normal subjects • The fluctuations in blood glucose levels impact contrast sensitivity scores. SWAP visual fields, intraocular pressure and diastolic pressure. This effect is similar for type 1 and type 2 diabetic patients despite the differences in their physiological status. • Long-term metabolic control in the diabetic patient is a useful predictor in the fluctuation of contrast sensitivity scores. • Large fluctuations in blood glucose levels and/or visual function and structure may be indicative of an increased risk of development or progression of retinopathy 3. Structural and functional damage of the visual pathway in glaucomatous optic neuropathy The glaucomatous eye undergoes a number of well documented pathological changes including retinal nerve fibre loss and optic nerve head damage which is correlated with loss of functional vision. In experimental glaucoma there is evidence that glaucomatous damage extends from retinal ganglion cells in the eye, along the visual pathway, to vision centres in the brain. This thesis explores the effects of glaucoma on retinal nerve fibre layer thickness, ocular anterior anatomy and cortical structure, and its correlates with visual function in humans. Principal findings were: • In the retina, glaucomatous retinal nerve fibre layer loss is less marked with increasing distance from the optic nerve head, suggesting that RNFL examination at a greater distance than traditionally employed may provide invaluable early indicators of glaucomatous damage • Neuroretinal rim area and retrobulbar optic nerve diameter are strong indicators of visual field loss • Grey matter density decreases at a rate of 3.85% per decade. There was no clear evidence of a disease effect • Cortical activation as measured by fMRI was a strong indicator of functional damage in patients with significant neuroretinal rim loss despite relatively modest visual field defects These investigations have shown that the effects of senescence are evident in both the anterior and posterior visual pathway. A variety of anatomical and functional diagnostic protocols for the investigation of damage to the visual pathway in ocular disease are required to maximise understanding of the disease processes and thereby optimising patient care.
Resumo:
Huge advertising budgets are invested by firms to reach and convince potential consumers to buy their products. To optimize these investments, it is fundamental not only to ensure that appropriate consumers will be reached, but also that they will be in appropriate reception conditions. Marketing research has focused on the way consumers react to advertising, as well as on some individual and contextual factors that could mediate or moderate the ad impact on consumers (e.g. motivation and ability to process information or attitudes toward advertising). Nevertheless, a factor that potentially influences consumers’ advertising reactions has not yet been studied in marketing research: fatigue. Fatigue can yet impact key variables of advertising processing, such as cognitive resources availability (Lieury 2004). Fatigue is felt when the body warns to stop an activity (or inactivity) to have some rest, allowing the individual to compensate for fatigue effects. Dittner et al. (2004) defines it as “the state of weariness following a period of exertion, mental or physical, characterized by a decreased capacity for work and reduced efficiency to respond to stimuli.’’ It signals that resources will lack if we continue with the ongoing activity. According to Schmidtke (1969), fatigue leads to troubles in information reception, in perception, in coordination, in attention getting, in concentration and in thinking. In addition, for Markle (1984) fatigue generates a decrease in memory, and in communication ability, whereas it increases time reaction, and number of errors. Thus, fatigue may have large effects on advertising processing. We suggest that fatigue determines the level of available resources. Some research about consumer responses to advertising claim that complexity is a fundamental element to take into consideration. Complexity determines the cognitive efforts the consumer must provide to understand the message (Putrevu et al. 2004). Thus, we suggest that complexity determines the level of required resources. To study this complex question about need and provision of cognitive resources, we draw upon Resource Matching Theory. Anand and Sternthal (1989, 1990) are the first to state the Resource Matching principle, saying that an ad is most persuasive when the resources required to process it match the resources the viewer is willing and able to provide. They show that when the required resources exceed those available, the message is not entirely processed by the consumer. And when there are too many available resources comparing to those required, the viewer elaborates critical or unrelated thoughts. According to the Resource Matching theory, the level of resource demanded by an ad can be high or low, and is mostly determined by the ad’s layout (Peracchio and Myers-Levy, 1997). We manipulate the level of required resources using three levels of ad complexity (low – high – extremely high). On the other side, the resource availability of an ad viewer is determined by lots of contextual and individual variables. We manipulate the level of available resources using two levels of fatigue (low – high). Tired viewers want to limit the processing effort to minimal resource requirements by making heuristics, forming overall impression at first glance. It will be easier for them to decode the message when ads are very simple. On the contrary, the most effective ads for viewers who are not tired are complex enough to draw their attention and fully use their resources. They will use more analytical strategies, looking at the details of the ad. However, if ads are too complex, they will be too difficult to understand. The viewer will be discouraged to process information and will overlook the ad. The objective of our research is to study fatigue as a moderating variable of advertising information processing. We run two experimental studies to assess the effect of fatigue on visual strategies, comprehension, persuasion and memorization. In study 1, thirty-five undergraduate students enrolled in a marketing research course participated in the experiment. The experimental design is 2 (tiredness level: between subjects) x 3 (ad complexity level: within subjects). Participants were randomly assigned a schedule time (morning: 8-10 am or evening: 10-12 pm) to perform the experiment. We chose to test subjects at various moments of the day to obtain maximum variance in their fatigue level. We use Morningness / Eveningness tendency of participants (Horne & Ostberg, 1976) as a control variable. We assess fatigue level using subjective measures - questionnaire with fatigue scales - and objective measures - reaction time and number of errors. Regarding complexity levels, we have designed our own ads in order to keep aspects other than complexity equal. We ran a pretest using the Resource Demands scale (Keller and Bloch 1997) and by rating them on complexity like Morrison and Dainoff (1972) to check for our complexity manipulation. We found three significantly different levels. After having completed the fatigue scales, participants are asked to view the ads on a screen, while their eye movements are recorded by the eye-tracker. Eye-tracking allows us to find out patterns of visual attention (Pieters and Warlop 1999). We are then able to infer specific respondents’ visual strategies according to their level of fatigue. Comprehension is assessed with a comprehension test. We collect measures of attitude change for persuasion and measures of recall and recognition at various points of time for memorization. Once the effect of fatigue will be determined across the student population, it is interesting to account for individual differences in fatigue severity and perception. Therefore, we run study 2, which is similar to the previous one except for the design: time of day is now within-subjects and complexity becomes between-subjects
Resumo:
AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.
Resumo:
Purpose: In today's competitive scenario, effective supply chain management is increasingly dependent on third-party logistics (3PL) companies' capabilities and performance. The dissemination of information technology (IT) has contributed to change the supply chain role of 3PL companies and IT is considered an important element influencing the performance of modern logistics companies. Therefore, the purpose of this paper is to explore the relationship between IT and 3PLs' performance, assuming that logistics capabilities play a mediating role in this relationship. Design/methodology/approach: Empirical evidence based on a questionnaire survey conducted on a sample of logistics service companies operating in the Italian market was used to test a conceptual resource-based view (RBV) framework linking IT adoption, logistics capabilities and firm performance. Factor analysis and ordinary least square (OLS) regression analysis have been used to test hypotheses. The focus of the paper is multidisciplinary in nature; management of information systems, strategy, logistics and supply chain management approaches have been combined in the analysis. Findings: The results indicate strong relationships among data gathering technologies, transactional capabilities and firm performance, in terms of both efficiency and effectiveness. Moreover, a positive correlation between enterprise information technologies and 3PL financial performance has been found. Originality/value: The paper successfully uses the concept of logistics capabilities as mediating factor between IT adoption and firm performance. Objective measures have been proposed for IT adoption and logistics capabilities. Direct and indirect relationships among variables have been successfully tested. © Emerald Group Publishing Limited.
Resumo:
Premium Intraocular Lenses (IOLs) such as toric IOLs, multifocal IOLs (MIOLs) and accommodating IOLs (AIOLs) can provide better refractive and visual outcomes compared to standard monofocal designs, leading to greater levels of post-operative spectacle independence. The principal theme of this thesis relates to the development of new assessment techniques that can help to improve future premium IOL design. IOLs designed to correct astigmatism form the focus of the first part of the thesis. A novel toric IOL design was devised to decrease the effect of toric rotation on patient visual acuity, but found to have neither a beneficial or detrimental impact on visual acuity retention. IOL tilt, like rotation, may curtail visual performance; however current IOL tilt measurement techniques require the use of specialist equipment not readily available in most ophthalmological clinics. Thus a new idea that applied Pythagoras’s theory to digital images of IOL optic symmetricality in order to calculate tilt was proposed, and shown to be both accurate and highly repeatable. A literature review revealed little information on the relationship between IOL tilt, decentration and rotation and so this was examined. A poor correlation between these factors was found, indicating they occur independently of each other. Next, presbyopia correcting IOLs were investigated. The light distribution of different MIOLs and an AIOL was assessed using perimetry, to establish whether this could be used to inform optimal IOL design. Anticipated differences in threshold sensitivity between IOLs were not however found, thus perimetry was concluded to be ineffective in mapping retinal projection of blur. The observed difference between subjective and objective measures of accommodation, arising from the influence of pseudoaccommodative factors, was explored next to establish how much additional objective power would be required to restore the eye’s focus with AIOLs. Blur tolerance was found to be the key contributor to the ocular depth of focus, with an approximate dioptric influence of 0.60D. Our understanding of MIOLs may be limited by the need for subjective defocus curves, which are lengthy and do not permit important additional measures to be undertaken. The use of aberrometry to provide faster objective defocus curves was examined. Although subjective and objective measures related well, the peaks of the MIOL defocus curve profile were not evident with objective prediction of acuity, indicating a need for further refinement of visual quality metrics based on ocular aberrations. The experiments detailed in the thesis evaluate methods to improve visual performance with toric IOLs. They also investigate new techniques to allow more rapid post-operative assessment of premium IOLs, which could allow greater insights to be obtained into several aspects of visual quality, in order to optimise future IOL design and ultimately enhance patient satisfaction.
Resumo:
Lutein and zeaxanthin are lipid-soluble antioxidants found within the macula region of the retina. Links have been suggested between increased levels of these carotenoids and reduced risk for age-related macular disease (ARMD). Therefore, the effect of lutein-based supplementation on retinal and visual function in people with early stages of ARMD (age-related maculopathy, ARM) was assessed using multi-focal electroretinography (mfERG), contrast sensitivity and distance visual acuity. A total of fourteen participants were randomly allocated to either receive a lutein-based oral supplement (treated group) or no supplement (non-treated group). There were eight participants aged between 56 and 81 years (65·50 (sd 9·27) years) in the treated group and six participants aged between 61 and 83 years (69·67 (sd 7·52) years) in the non-treated group. Sample sizes provided 80 % power at the 5 % significance level. Participants attended for three visits (0, 20 and 40 weeks). At 60 weeks, the treated group attended a fourth visit following 20 weeks of supplement withdrawal. No changes were seen between the treated and non-treated groups during supplementation. Although not clinically significant, mfERG ring 3 N2 latency (P= 0·041) and ring 4 P1 latency (P= 0·016) increased, and a trend for reduction of mfERG amplitudes was observed in rings 1, 3 and 4 on supplement withdrawal. The statistically significant increase in mfERG latencies and the trend for reduced mfERG amplitudes on withdrawal are encouraging and may suggest a potentially beneficial effect of lutein-based supplementation in ARM-affected eyes. Copyright © 2012 The Authors.
Resumo:
Purpose. To convert objective image analysis of anterior ocular surfaces into recognisable clinical grades, in order to provide a more sensitive and reliable equivalent to current subjective grading methods; a prospective, randomized study correlating clinical grading with digital image assessment. Methods. The possible range of clinical presentations Of bulbar and palpebral hyperaemia, palpebral roughness and corneal staining were represented by 4 sets of 10 images. The images were displayed in random order and graded by 50 clinicians using both subjective CCLRU and Efron grading scales. Previously validated objective image analysis was performed 3 times oil each of the 40 images. Digital measures included edge-detection and relative-coloration components. Step-wise regression analysis determined correlations between the average subjective grade and the objective image analysis measures. Results. Average subjective grades Could be predicted by a combination of the objective image analysis components. These digital ``grades'' accounted for between 69%, (for Efron scale-graded palpebral redness) and 98% (for Efron scale-graded bulbar hyperaemia) of the subjective variance. Conclusions. The results indicate that clinicians may use a combination of vessel areas and overall hue in their judgment of clinical severity for certain conditions. Objective grading call take these aspects into account, and be used to predict an average ``objective grade'' to be used by a clinician in describing the anterior eye. These measures are more sensitive and reliable than subjective grading while still utilizing familiar terminology, and can be applied in research or practice to improve the detection, and monitoring of ocular surface changes.
Resumo:
Objectives: To develop an objective measure to enable hospital Trusts to compare their use of antibiotics. Design: Self-completion, postal questionnaire with telephone follow up. Sample: 4 hospital trusts in the English Midlands. Results: The survey showed that it was possible to collect data concerning the number of Defined Daily Doses (DDD's) of quinolone antibiotic dispensed per Finished Consultant Episode (FCE) in each Trust.. In the 4 trusts studied the mean DDD/FCE was 0.197 (range 0.117 to 0.258). This indicates that based on a typical course length of 5 days, 3.9% of patient episodes resulted in the prescription of a quinolone antibiotic. Antibiotic prescribing control measures in each Trust were found to be comparable. Conclusion: The measure will enable Trusts to objectively compare their usage of quinolone antibiotics and use this information to carry out clinical audit should differences be recorded. This is likely to be applicable to other groups of antibiotics.
Resumo:
Structural retinal vascular characteristics, such as vessel calibers, tortuosity and bifurcation angles are increasingly quantified in an objective manner, slowly replacing subjective qualitative disease classification schemes. This paper provides an overview of the current methodologies and calculations used to compute retinal vessel tortuosity. We set out the different parameter calculations and provide an insight into the clinical applications, while critically reviewing its pitfalls and shortcomings.
Resumo:
Aim: To determine whether eyes implanted with the Lenstec KH-3500 "accommodative" intraocular lenses (IOLs) have improved subjective and objective focusing performance compared to a standard monofocal IOLs. Methods: 28 participants were implanted monocularly with a KH-3500 " accommodative" IOL and 20 controls with a Softec1 IOL. Outcome measures of refraction, visual acuity, subjective amplitude of accommodation, objective accommodative stimulus response curve, aberrometry, and Scheimpflug imaging were taken at ∼3 weeks and repeated after 6 months. Results: Best corrected acuity with the KH-3500 was 0.06 (SD 0.13) logMAR at distance and 0.58 (0.20) logMAR at near. Accommodation was 0.39 (0.53) D measured objectively and 3.1 (1.6) D subjectively. Higher order aberrations were 0.87 (0.85) μm and lower order were 0.24 (0.39) μm. Posterior subcapsular light scatter was 0.95% (1.37%) greater than IOL clarity. In comparison, all control group measures were similar except objective (0.17 (0.13) D; p = 0.032) and subjective (2.0 (0.9) D; p = 0.009) amplitude of accommodation. Six months following surgery, posterior subcapsular scatter had increased (p<0.01) in the KH-3500 implanted subjects and near word acuity had decreased (p<0.05). Conclusions: The objective accommodating effects of the KH-3500 IOL appear to be limited, although the subjective and objective accommodative range is significantly increased compared to control subjects implanted with conventional IOLs. However, this "accommodative" ability of the lens appears to have decreased by 6 months post-surgery.
Resumo:
PURPOSE. To compare the objective accommodative amplitude and dynamics of eyes implanted with the one-compartment-unit (1CU; HumanOptics AG, Erlangen, Germany) accommodative intraocular lenses (IOLs) with that measured subjectively. METHODS. Twenty eyes with a 1CU accommodative IOL implanted were refracted and distance and near acuity measured with a logMAR (logarithm of the minimum angle of resolution) chart. The objective accommodative stimulus-response curve for static targets between 0.17 and 4.00 D accommodative demand was measured with the SRW-5000 (Shin-Nippon Commerce Inc., Tokyo, Japan) and PowerRefractor (PlusOptiX, Nürnberg, Germany) autorefractors. Continuous objective recording of dynamic accommodation was measured with the SRW-5000, with the subject viewing a target moving from 0 to 2.50 D at 0.3 Hz through a Badal lens system. Wavefront aberrometry measures (Zywave; Bausch & Lomb, Rochester, NY) were made through undilated pupils. Subjective amplitude of accommodation was measured with the RAF (Royal Air Force accommodation and vergence measurement) rule. RESULTS. Four months after implantation best-corrected acuity was -0.01 ± 0.16 logMAR at distance and 0.60 ± 0.09 logMAR at near. Objectively, the static amplitude of accommodation was 0.72 ± 0.38 D. The average dynamic amplitude of accommodation was 0.71 ± 0.47 D, with a lag behind the target of 0.50 ± 0.48 seconds. Aberrometry showed a decrease in power of the lens-eye combination from the center to the periphery in all subjects (on average, -0.38 ± 0.28 D/mm). Subjective amplitude of accommodation was 2.24 ± 0.42 D. Two years after 1CU implantation, refractive error and distance visual acuity remained relatively stable, but near visual acuity, and the subjective and objective amplitudes of accommodation decreased. CONCLUSIONS. The objective accommodating effects of the 1CU lens appear to be limited, although patients are able to track a moving target. Subjective and objective accommodation was reduced at the 2-year follow-up. The greater subjective amplitude of accommodation is likely to result from the eye's depth of focus of and the aspheric nature of the IOL. Copyright © Association for Research in Vision and Ophthalmology.
Resumo:
Aim: To use previously validated image analysis techniques to determine the incremental nature of printed subjective anterior eye grading scales. Methods: A purpose designed computer program was written to detect edges using a 3 × 3 kernal and to extract colour planes in the selected area of an image. Annunziato and Efron pictorial, and CCLRU and Vistakon-Synoptik photographic grades of bulbar hyperaemia, palpebral hyperaemia roughness, and corneal staining were analysed. Results: The increments of the grading scales were best described by a quadratic rather than a linear function. Edge detection and colour extraction image analysis for bulbar hyperaemia (r2 = 0.35-0.99), palpebral hyperaemia (r2 = 0.71-0.99), palpebral roughness (r2 = 0.30-0.94), and corneal staining (r2 = 0.57-0.99) correlated well with scale grades, although the increments varied in magnitude and direction between different scales. Repeated image analysis measures had a 95% confidence interval of between 0.02 (colour extraction) and 0.10 (edge detection) scale units (on a 0-4 scale). Conclusion: The printed grading scales were more sensitive for grading features of low severity, but grades were not comparable between grading scales. Palpebral hyperaemia and staining grading is complicated by the variable presentations possible. Image analysis techniques are 6-35 times more repeatable than subjective grading, with a sensitivity of 1.2-2.8% of the scale.
Resumo:
Context Many large organizations juggle an application portfolio that contains different applications that fulfill similar tasks in the organization. In an effort to reduce operating costs, they are attempting to consolidate such applications. Before consolidating applications, the work that is done with these applications must be harmonized. This is also known as process harmonization. Objective The increased interest in process harmonization calls for measures to quantify the extent to which processes have been harmonized. These measures should also uncover the factors that are of interest when harmonizing processes. Currently, such measures do not exist. Therefore, this study develops and validates a measurement model to quantify the level of process harmonization in an organization. Method The measurement model was developed by means of a literature study and structured interviews. Subsequently, it was validated through a survey, using factor analysis and correlations with known related constructs. Results As a result, a valid and reliable measurement model was developed. The factors that are found to constitute process harmonization are: the technical design of the business process and its data, the resources that execute the process, and the information systems that are used in the process. In addition, strong correlations were found between process harmonization and process standardization and between process complexity and process harmonization. Conclusion The measurement model can be used by practitioners, because it shows them the factors that must be taken into account when harmonizing processes, and because it provides them with a means to quantify the extent to which they succeeded in harmonizing their processes. At the same time, it can be used by researchers to conduct further empirical research in the area of process harmonization.
Resumo:
Primary objective: To assess the relationship between disability, length of stay (LOS) and anticholinergic burden (ACB) with people following acquired brain or spinal cord injury. Research design: A retrospective case note review assessed total rehabilitation unit admission. Methods and procedures: Assessment of 52 consecutive patients with acquired brain/spinal injury and neuropathy in an in-patient neuro-rehabilitation unit of a UK university hospital. Data analysed included: Northwick Park Dependency Score (NPDS), Rehabilitation complexity Scale (RCS), Functional Independence Measure and Functional Assessment Measure FIM-FAM (UK version 2.2), LOS and ACB. Outcome was different in RCS, NPDS and FIM-FAM between admission and discharge. Main outcomes and results: A positive change was reported in ACB results in a positive change in NPDS, with no significant effect on FIM-FAM, either Motor or Cognitive, or on the RCS. Change in ACB correlated to the length of hospital stay (regression correlation = −6.64; SE = 3.89). There was a significant harmful impact of increase in ACB score during hospital stay, from low to high ACB on NPDS (OR = 9.65; 95% CI = 1.36–68.64) and FIM-FAM Total scores (OR = 0.03; 95% CI = 0.002–0.35). Conclusions: There was a statistically significant correlation of ACB and neuro-disability measures and LOS amongst this patient cohort.
Resumo:
Purpose: To determine whether the ‘through-focus’ aberrations of a multifocal and accommodative intraocular lens (IOL) implanted patient can be used to provide rapid and reliable measures of their subjective range of clear vision. Methods: Eyes that had been implanted with a concentric (n = 8), segmented (n = 10) or accommodating (n = 6) intraocular lenses (mean age 62.9 ± 8.9 years; range 46-79 years) for over a year underwent simultaneous monocular subjective (electronic logMAR test chart at 4m with letters randomised between presentations) and objective (Aston open-field aberrometer) defocus curve testing for levels of defocus between +1.50 to -5.00DS in -0.50DS steps, in a randomised order. Pupil size and ocular aberration (a combination of the patient’s and the defocus inducing lens aberrations) at each level of blur was measured by the aberrometer. Visual acuity was measured subjectively at each level of defocus to determine the traditional defocus curve. Objective acuity was predicted using image quality metrics. Results: The range of clear focus differed between the three IOL types (F=15.506, P=0.001) as well as between subjective and objective defocus curves (F=6.685, p=0.049). There was no statistically significant difference between subjective and objective defocus curves in the segmented or concentric ring MIOL group (P>0.05). However a difference was found between the two measures and the accommodating IOL group (P<0.001). Mean Delta logMAR (predicted minus measured logMAR) across all target vergences was -0.06 ± 0.19 logMAR. Predicted logMAR defocus curves for the multifocal IOLs did not show a near vision addition peak, unlike the subjective measurement of visual acuity. However, there was a strong positive correlation between measured and predicted logMAR for all three IOLs (Pearson’s correlation: P<0.001). Conclusions: Current subjective procedures are lengthy and do not enable important additional measures such as defocus curves under differently luminance or contrast levels to be assessed, which may limit our understanding of MIOL performance in real-world conditions. In general objective aberrometry measures correlated well with the subjective assessment indicating the relative robustness of this technique in evaluating post-operative success with segmented and concentric ring MIOL.