21 resultados para Non-invasive method


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Biopharmaceuticals are finding wide applications in the management of diverse disease conditions. Pulmonary delivery of proteins may constitute an effective and efficient non-invasive alternative to parenteral delivery, which is currently the main route of administration of biopharmaceutical drugs. A particular area, in which pulmonary delivery of peptides and proteins may find ready application, is in the local delivery of antimicrobial peptides and proteins to the airway, a measure that could potentially bring about improvements to currently available antipseudomonal therapies. This thesis has therefore sought to develop inhalable antimicrobial proteins in combination with antibiotics that have particularly good antimicrobial activity against Pseudomonas aeruginosa infections in the respiratory tract of people with cystic fibrosis (CF). Through process optimisation, a suitable spray drying method was developed and used for the preparation of active, inhalable dry powder formulations of the antimicrobial protein, lactoferrin, and aminoglycosides (tobramycin and gentamicin). The physicochemical properties, aerosolisation performance and the antibacterial properties of the various spray-dried formulations were assessed. In addition, a relevant in vitro cellular model was employed to investigate the potential cytotoxic and pro-inflammatory effects of the various formulations on four bronchial human epithelial cells together with their effectiveness at reducing bacterial colonies when administered on to biofilm co-cultured on the epithelial cells. It was found that following spray drying the particles obtained were mostly spherical, amorphous and possessed suitable aerosolisation characteristics. The various spray-dried antimicrobial proteins (lactoferrin or apo lactoferrin) and co-spray dried combinations of the proteins and aminoglycosides were found to exhibit bactericidal activity against planktonic and biofilms of P. aeruginosa. In general, the spray drying process was found not to significantly affect the antimicrobial activities of the protein. Treatment of the different bronchial epithelial cell lines with the antimicrobial formulations showed that the various formulations were non-toxic and that the co-spray dried combinations significantly reduced established P. aeruginosa biofilms on the four bronchial epithelial cells. Overall, the results from this thesis demonstrates that spray drying could potentially be employed to prepare inhalable antimicrobial agents comprised of proteins and antibiotics. These new combinations of proteins and aminoglycosides has promising applications in the management of P. aeruginosa in the airway of cystic fibrosis patients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

MEG beamformer algorithms work by making the assumption that correlated and spatially distinct local field potentials do not develop in the human brain. Despite this assumption, images produced by such algorithms concur with those from other non-invasive and invasive estimates of brain function. In this paper we set out to develop a method that could be applied to raw MEG data to explicitly test his assumption. We show that a promax rotation of MEG channel data can be used as an approximate estimator of the number of spatially distinct correlated sources in any frequency band.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose - To generate a reflectance model of the fundus that allows an accurate non-invasive quantification of blood and pigments. Methods - A Monte Carlo simulation was used to produce a mathematical model of light interaction with the fundus at different wavelengths. The model predictions were compared with fundus images from normal volunteers in several spectral bands (peaks at 507, 525, 552, 585, 596 and 611nm). Th e model was then used to calculate the concentration and distribution of the known absorbing components of the fundus. Results - The shape of the statistical distribution of the image data generally corresponded to that of the model data; the model however appears to overestimate the reflectance of the fundus in the longer wavelength region.As the absorption by xanthophyll has no significant eff ect on light transport above 534nm, its distribution in the fundus was quantified: the wavelengths where both shape and distribution of image and model data matched (<553nm) were used to train a neural network which was then applied to every point in the image data. The xanthophyll distribution thus found was in agreement with published literature data in normal subjects. Conclusion - We have developed a method for optimising multi-spectral imaging of the fundus and a computer image analysis capable of estimating information about the structure and properties of the fundus. Th e technique successfully calculates the distribution of xanthophyll in the fundus of healthy volunteers. Further improvement of the model is required to allow the deduction of other parameters from images; investigations in known pathology models are also necessary to establish if this method is of clinical use in detecting early chroido-retinopathies, hence providing a useful screening and diagnostic tool.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Bio-impedance analysis (BIA) provides a rapid, non-invasive technique for body composition estimation. BIA offers a convenient alternative to standard techniques such as MRI, CT scan or DEXA scan for selected types of body composition analysis. The accuracy of BIA is limited because it is an indirect method of composition analysis. It relies on linear relationships between measured impedance and morphological parameters such as height and weight to derive estimates. To overcome these underlying limitations of BIA, a multi-frequency segmental bio-impedance device was constructed through a series of iterative enhancements and improvements of existing BIA instrumentation. Key features of the design included an easy to construct current-source and compact PCB design. The final device was trialled with 22 human volunteers and measured impedance was compared against body composition estimates obtained by DEXA scan. This enabled the development of newer techniques to make BIA predictions. To add a ‘visual aspect’ to BIA, volunteers were scanned in 3D using an inexpensive scattered light gadget (Xbox Kinect controller) and 3D volumes of their limbs were compared with BIA measurements to further improve BIA predictions. A three-stage digital filtering scheme was also implemented to enable extraction of heart-rate data from recorded bio-electrical signals. Additionally modifications have been introduced to measure change in bio-impedance with motion, this could be adapted to further improve accuracy and veracity for limb composition analysis. The findings in this thesis aim to give new direction to the prediction of body composition using BIA. The design development and refinement applied to BIA in this research programme suggest new opportunities to enhance the accuracy and clinical utility of BIA for the prediction of body composition analysis. In particular, the use of bio-impedance to predict limb volumes which would provide an additional metric for body composition measurement and help distinguish between fat and muscle content.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: To investigate if magnetoencephalography (MEG) can identify implantation sites for intracranial recordings (IR). Method: Two groups of 12 patients assessed for surgery with IR with and without MEG were compared (MEG and control groups). In the control group, non-invasive presurgical assessment without MEG suggested clear hypotheses for implantation. In the MEG group, non-invasive assessment was inconclusive, and MEG was used to identify implantation sites. Both groups were matched for implantation type. The success of implantation was defined by findings in IR: a) Focal seizure onset; b)Unilateral focal abnormal responses to single pulse electrical stimulation(SPES); and c) Concordance between a) and b). Results: In all MEG patients, at least one virtual MEG electrode generated suitable hypotheses for the location of implantations. The proportion of patients showing focal seizure onset restricted to one hemisphere was similar in control and MEG groups (6/12 vs. 11/12, Fisher’s exact test,p = 0.0686). The proportion of patients showing unilateral responses to SPES was lower in the control than in the MEG group (7/12 vs. 12/12,p = 0.0373). Conclusion: The MEG group showed similar or higher incidence of successful implantations than controls.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Transcranial direct current stimulation (tDCS) is a method of non-invasive brain stimulation widely used to modulate cognitive functions. Recent studies, however, suggests that effects are unreliable, small and often non-significant at least when stimulation is applied in a single session to healthy individuals. We examined the effects of frontal and temporal lobe anodal tDCS on naming and reading tasks and considered possible interactions with linguistic activation and selection mechanisms as well possible interactions with item difficulty and participant individual variability. Across four separate experiments (N, Exp 1A = 18; 1B = 20; 1C = 18; 2 = 17), we failed to find any difference between real and sham stimulation. Moreover, we found no evidence of significant effects limited to particular conditions (i.e., those requiring suppression of semantic interference), to a subset of participants or to longer RTs. Our findings sound a cautionary note on using tDCS as a means to modulate cognitive performance. Consistent effects of tDCS may be difficult to demonstrate in healthy participants in reading and naming tasks, and be limited to cases of pathological neurophysiology and/or to the use of learning paradigms.