21 resultados para Low-dose


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Accurate measurement of intervertebral kinematics of the cervical spine can support the diagnosis of widespread diseases related to neck pain, such as chronic whiplash dysfunction, arthritis, and segmental degeneration. The natural inaccessibility of the spine, its complex anatomy, and the small range of motion only permit concise measurement in vivo. Low dose X-ray fluoroscopy allows time-continuous screening of cervical spine during patient's spontaneous motion. To obtain accurate motion measurements, each vertebra was tracked by means of image processing along a sequence of radiographic images. To obtain a time-continuous representation of motion and to reduce noise in the experimental data, smoothing spline interpolation was used. Estimation of intervertebral motion for cervical segments was obtained by processing patient's fluoroscopic sequence; intervertebral angle and displacement and the instantaneous centre of rotation were computed. The RMS value of fitting errors resulted in about 0.2 degree for rotation and 0.2 mm for displacements. © 2013 Paolo Bifulco et al.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Esophageal cancer is the eighth most common cancer seen worldwide and is the sixth most common cause of death from cancer. The UK alone has over 8,000 new cases of esophageal cancer every year. Epidemiological studies have shown that low-dose daily intake of aspirin can decrease the incidence of esophageal cancer. However, its use as an anti-cancer drug has been restrained because of its side effects exerted through inhibition of cyclooxygenase (COX) enzymes. In our study, we have investigated the effects of a number of novel aspirin analogs on esophageal cancer cell lines. Methods: The effects of aspirin and its analogs on the viability of esophageal cancer cell lines were tested using the MTT assay. ApoSense and flow cytometric analysis were performed to examine whether aspirin analog-mediated tumor cell death is due to apoptosis or necrosis. Colorimetric assays measuring peroxidase component of cyclooxygenases were employed to screen aspirin analogs for COX inhibition. Results: Our data suggests that the anti-proliferative property of certain aspirin analogs is greater than that of aspirin itself. Benzoylsalicylates and fumaroyl diaspirin were more effective than aspirin against the oe21 squamous cell carcinoma cells and oe33 esophageal adenocarcinoma cells. Flo-1 esophageal adenocarcinoma cells showed resistance to aspirin and most of the aspirin analogs other than the benzoylsalicylates. Both diaspirin and benzoylsalicylates inhibited metabolic activity in all these esophageal cells. However, apoptosis was induced in only a small proportion. We have also shown that these aspirin analogs do not appear to inhibit COX enzymes. Conclusion: We have synthesized and characterized a number of novel aspirin analogs that are more effective against esophageal cancer cell lines than aspirin. These compounds do not exert their anti-proliferative effect through induction of apoptosis. Moreover, these analogs inability to inhibit COX enzymes suggests that they may cause fewer or no side effects compared to aspirin.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

EPA has been clinically shown to reduce muscle wasting during cancer cachexia. This study investigates whether curcumin or green tea extract (GTE) enhances the ability of low doses of eicosapentaenoic acid (EPA) to reduce loss of muscle protein in an in vitro model. A low dose of EPA with minimal anti-cachectic activity was chosen to evaluate any potential synergistic effect with curcumin or GTE. Depression of protein synthesis and increase in degradation was determined in C2C12 myotubes in response to tumour necrosis factor-α (TNF-α) and proteolysis-inducing factor (PIF). EPA (50 μM) or curcumin (10 μg ml−1) alone had little effect on protein degradation caused by PIF but the combination produced complete inhibition, as did the combination with GTE (10 μg ml−1). In response to TNF-α (25 ng ml−1)-induced protein degradation, EPA had a small, but not significant effect on protein degradation; however, when curcumin and GTE were combined with EPA, the effect was enhanced. EPA completely attenuated the depression of protein synthesis caused by TNF-α, but not that caused by PIF. The combination of EPA with curcumin produced a significant increase in protein synthesis to both agents. GTE alone or in combination with EPA had no effect on the depression of protein synthesis by TNF-α, but did significantly increase protein synthesis in PIF-treated cells. Both TNF-α and PIF significantly reduced myotube diameter from 17 to 13 μm for TNF-α (23.5%) and 15 μm (11.8%) for PIF However the triple combination of EPA, curcumin and GTE returned diameters to values not significantly different from the control. These results suggest that either curcumin or GTE or the combination could enhance the anti-catabolic effect of EPA on lean body mass.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of low energy nitrogen molecular ion beam bombardment on metals and compound semiconductors has been studied, with the aim to investigate at the effects of ion and target properties. For this purpose, nitrogen ion implantation in aluminium, iron, copper, gold, GaAs and AIGaAs is studied using XPS and Angle Resolve XPS. A series of experimental studies on N+2 bombardment induced compositional changes, especially the amount of nitrogen retained in the target, were accomplished. Both monoenergetic implantation and non-monoenergetic ion implantation were investigated, using the VG Scientific ESCALAB 200D system and a d. c. plasma cell, respectively. When the samples, with the exception of gold, are exposed to air, native oxide layers are formed on the surfaces. In the case of monoenergetic implantation, the surfaces were cleaned using Ar+ beam bombardment prior to implantation. The materials were then bombarded with N2+ beam and eight sets of successful experiments were performed on each sample, using a rastered N2+ ion beam of energy of 2, 3, 4 and 5 keV with current densities of 1 μA/cm2 and 5 μA/cm22 for each energy. The bombarded samples were examined by ARXPS. After each complete implantation, XPS depth profiles were created using Ar+ beam at energy 2 ke V and current density 2 μA/cm2 . As the current density was chosen as one of the parameters, accurate determination of current density was very important. In the case of glow discharge, two sets of successful experiments were performed in each case, by exposing the samples to nitrogen plasma for the two conditions: at low pressure and high voltage and high pressure and low voltage. These samples were then examined by ARXPS. On the theoretical side, the major problem was prediction of the number of ions of an element that can be implanted in a given matrix. Although the programme is essentially on experimental study, but an attempt is being made to understand the current theoretical models, such as SATVAL, SUSPRE and TRIM. The experimental results were compared with theoretical predictions, in order to gain a better understanding of the mechanisms responsible. From the experimental results, considering possible experimental uncertainties, there is no evidence of significant variation in nitrogen saturation concentration with ion energy or ion current density in the range of 2-5 ke V, however, the retention characteristics of implantant seem to strongly depend on the chemical reactivity between ion species and target material. The experimental data suggests the presence of at least one thermal process. The discrepancy between the theoretical and experimental results could be the inability of the codes to account for molecular ion impact and thermal processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: In the light of sub-optimal uptake of the measles, mumps, and rubella (MMR) vaccination, we investigated the factors that influence the intentions of mothers to vaccinate. METHOD: A cross-sectional survey of 300 mothers in Birmingham with children approaching a routine MMR vaccination was conducted using a postal questionnaire to measure: intention to vaccinate, psychological variables, knowledge of the vaccine, and socioeconomic status. The vaccination status of the children was obtained from South Birmingham Child Health Surveillance Unit. RESULTS: The response rate was 59%. Fewer mothers approaching the second MMR vaccination (Group 2) intended to take their children for this vaccination than Group 1 (mothers approaching the first MMR vaccination) (Mann-Whitney U = 2180, P < 0.0001). Group 2 expressed more negative beliefs about the outcome of having the MMR vaccine ('vaccine outcome beliefs') (Mann-Whitney U = 2155, P < 0.0001), were more likely to believe it was 'unsafe' (chi 2 = 9.114, P = 0.004) and that it rarely protected (chi 2 = 6.882, P = 0.014) than Group 1. The commonest side-effect cited was general malaise, but 29.8% cited autism. The most trusted source of information was the general practitioner but the most common source of information on side-effects was television (34.6%). Multiple linear regression revealed that, in Group 1, only 'vaccine outcome beliefs' significantly predicted intention (77.1% of the variance). In Group 2 'vaccine outcome beliefs', attitude to the MMR vaccine, and prior MMR status all predicted intention (93% of the variance). CONCLUSION: A major reason for the low uptake of the MMR vaccination is that it is not perceived to be important for children's health, particularly the second dose. Health education from GPs is likely to have a considerable impact.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is an urgent need for fast, non-destructive and quantitative two-dimensional dopant profiling of modern and future ultra large-scale semiconductor devices. The low voltage scanning electron microscope (LVSEM) has emerged to satisfy this need, in part, whereby it is possible to detect different secondary electron yield values (brightness in the SEM signal) from the p-type to the n-type doped regions as well as different brightness levels from the same dopant type. The mechanism that gives rise to such a secondary electron (SE) contrast effect is not fully understood, however. A review of the different models that have been proposed to explain this SE contrast is given. We report on new experiments that support the proposal that this contrast is due to the establishment of metal-to-semiconductor surface contacts. Further experiments showing the effect of instrument parameters including the electron dose, the scan speeds and the electron beam energy on the SE contrast are also reported. Preliminary results on the dependence of the SE contrast on the existence of a surface structure featuring metal-oxide semiconductor (MOS) are also reported. Copyright © 2005 John Wiley & Sons, Ltd.