28 resultados para Jump-out-of-contact phenomena
Resumo:
More information on the biochemical interactions taking place between the tear film and the contact lens is required to further our understanding of the causative mechanisms behind the symptoms of dryness and grittiness often experienced by contact lens wearers. These symptoms can often lead to an intolerance to contact lens wear.
Resumo:
Effective measures are being taken to reduce emissions from cars, which are now emerging as a major contributor to climate change. Developed countries will need to reduce emissions by at least 80% by 2050 to achieve stabilization of atmospheric CO2 concentration between 450 and 550 ppm, and have a unique opportunity to avoid the most damaging effects of climate change. The UK is aiming at completely decarbonising transport by 2050 through a combination of more efficient vehicles, cleaner fuels, and smart driving choices. The European Commission has proposed a mandatory CO2 target on new car CO 2 efficiency, which is an urgent needed development. The nation is also using regulatory targets for local schemes, such as free parking or congestion charging, break points for company car tax, and vehicle excise duty. Car ownership and use should thereby continue to drive economic growth and enhance quality of life around the world without destroying the planet.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.
Resumo:
The poor retention and efficacy of instilled drops as a means of delivering drugs to the ophthalmic environment is well-recognised. The potential value of contact lenses as a means of ophthalmic drug delivery, and consequent improvement of pre-corneal retention is one obvious route to the development of a more effective ocular delivery system. Furthermore, the increasing availability and clinical use of daily disposable contact lenses provides the platform for the development of viable single-day use drug delivery devices based on existing materials and lenses. In order to provide a basis for the effective design of such devices, a systematic understanding of the factors affecting the interaction of individual drugs with the lens matrix is required. Because a large number of potential structural variables are involved, it is necessary to achieve some rationalisation of the parameters and physicochemical properties (such as molecular weight, charge, partition coefficients) that influence drug interactions. Ophthalmic dyes and structurally related compounds based on the same core structure were used to investigate these various factors and the way in which they can be used in concert to design effective release systems for structurally different drugs. Initial studies of passive diffusional release form a necessary precursor to the investigation of the features of the ocular environment that over-ride this simple behaviour. Commercially available contact lenses of differing structural classifications were used to study factors affecting the uptake of the surrogate actives and their release under 'passive' conditions. The interaction between active and lens material shows considerable and complex structure dependence, which is not simply related to equilibrium water content. The structure of the polymer matrix itself was found to have the dominant controlling influence on active uptake; hydrophobic interaction with the ophthalmic dye playing a major role. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.
Resumo:
This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.
Resumo:
The return to methods focusing on language and experience following the dominance of experimental methods has in the last few decades led to debate, dialogue, and disagreement regarding the status of qualitative and quantitative methods. However, a recent focus on impact has brought an air of pragmatism to the research arena. In what ways, then, is psychology moving from entrenched mono methods approaches that have epitomised its development until recently, to describing and discussing ways in which mixed and pluralistic research can advance and contribute to further, deeper psychological understanding?.
Resumo:
This research aims to contribute to understanding the implementation of knowledge management systems (KMS) in the field of health through a case study, leading to theory building and theory extension. We use the concept of the business process approach to knowledge management as a theoretical lens to analyse and explore how a large teaching hospital developed, executed and practically implemented a KMS. A qualitative study was conducted over a 2.5 year period with data collected from semi-structured interviews with eight members of the strategic management team, 12 clinical users and 20 patients in addition to non-participant observation of meetings and documents. The theoretical propositions strategy was used as the overarching approach for data analysis. Our case study provides evidence that true patient centred approaches to supporting care delivery with a KMS benefit from process thinking at both the planning and implementation stages, and an emphasis on the knowledge demands resulting from: the activities along the care pathways; where cross-overs in care occur; and knowledge sharing for the integration of care. The findings also suggest that despite the theoretical awareness of KMS implementation methodologies, the actual execution of such systems requires practice and learning. Flexible, fluid approaches through rehearsal are important and communications strategies should focus heavily on transparency incorporating both structured and unstructured communication methods.
Resumo:
Based on the emergent findings of a pilot study which examined the issues around introducing Peer Mentoring into an Engineering School, this paper, which is very much a 'work in progress', describes and discusses results from the first year of what will be a three year exploratory study. Focusing on three distinctive concepts integral to the student experience, Relationships, Variety and Synergy, the study follows an Action Research Design in that it aims to find a realistic and workable solution to issues of attrition within the Engineering School in which the Project and Study are set. Starting with the research question "Does Peer Mentoring improve engineering students' transition into university?"', the Pilot Project and Study will run for three years, each year building on the lessons of the previous year.
Resumo:
Intercultural communication in the global environment frequently involves recourse to translation. This generates new phenomena which, in turn, raise new questions for translation theory and practice. This issue is concerned with the concept of the hybrid text as one of these phenomena. In this introductory chapter, a hybrid text is defined as: „a text that results from a translation process. It shows features that somehow seem ‘out of place'/‘strange'/‘unusual' for the receiving culture, i.e. the target culture”. It is important, however, to differentiate between the true hybrid, which is the result of positive authorial and/or translatorial decisions, and the inadequate text which exhibits features of translationese, resulting from a lack of competence. Textual, contextual and social features of hybrid texts are postulated (see discussion paper). These are the object of critical reflection in sub-sequent chapters, in relation to different genres. The potential of the hybrid text for translation research is explored.
Resumo:
Approximately half of current contact lens wearers suffer from dryness and discomfort, particularly towards the end of the day. Contact lens practitioners have a number of dry eye tests available to help them to predict which of their patients may be at risk of contact lens drop out and advise them accordingly. This thesis set out to rationalize them to see if any are of more diagnostic significance than others. This doctorate has found: (1) The Keratograph, a device which permits an automated, examiner independent technique for measuring non invasive tear break up time (NITBUT) measured NITBUT consistently shorter than measurements recorded with the Tearscope. When measuring central corneal curvature the spherical equivalent power of the cornea was measured as being significantly flatter than with a validated automated keratometer. (2) Non-invasive and invasive tear break-up times significantly correlated to each other, but not the other tear metrics. Symptomology, assessed using the OSDI questionnaire, correlated more with those tests indicating possible damage to the ocular surface (including LWE, LIPCOF and conjunctival staining) than with tests of either tear volume or stability. Cluster analysis showed some statistically significant groups of patients with different sign and symptom profiles. The largest cluster demonstrated poor tear quality with both non-invasive and invasive tests, low tear volume and more symptoms. (3) Care should be taken in fitting patients new to contact lenses if they have a NITBUT less than 10s or an OSDI comfort rating greater than 4.2 as they are more likely to drop-out within the first 6 months. Cluster analysis was not found to be beneficial in predicting which patients will succeed with lenses and which will not. A combination of the OSDI questionnaire and a NITBUT measurement was most useful both in diagnosing dry eye and in predicting contact lens drop out.
Resumo:
Purpose: To assess the compliance of Daily Disposable Contact Lenses (DDCLs) wearers with replacing lenses at a manufacturer-recommended replacement frequency. To evaluate the ability of two different Health Behavioural Theories (HBT), The Health Belief Model (HBM) and The Theory of Planned Behaviour (TPB), in predicting compliance. Method: A multi-centre survey was conducted using a questionnaire completed anonymously by contact lens wearers during the purchase of DDCLs. Results: Three hundred and fifty-four questionnaires were returned. The survey comprised 58.5% females and 41.5% males (mean age 34. ±. 12. years). Twenty-three percent of respondents were non-compliant with manufacturer-recommended replacement frequency (re-using DDCLs at least once). The main reason for re-using DDCLs was "to save money" (35%). Predictions of compliance behaviour (past behaviour or future intentions) on the basis of the two HBT was investigated through logistic regression analysis: both TPB factors (subjective norms and perceived behavioural control) were significant (p. <. 0.01); HBM was less predictive with only the severity (past behaviour and future intentions) and perceived benefit (only for past behaviour) as significant factors (p. <. 0.05). Conclusions: Non-compliance with DDCLs replacement is widespread, affecting 1 out of 4 Italian wearers. Results from the TPB model show that the involvement of persons socially close to the wearers (subjective norms) and the improvement of the procedure of behavioural control of daily replacement (behavioural control) are of paramount importance in improving compliance. With reference to the HBM, it is important to warn DDCLs wearers of the severity of a contact-lens-related eye infection, and to underline the possibility of its prevention.