Presbyopia is an age-related eye condition where one of the signs is the reduction in the amplitude of accommodation, resulting in the loss of ability to change the eye's focus from far to near. It is the most common age-related ailments affecting everyone around their mid-40s. Methods for the correction of presbyopia include contact lens and spectacle options but the surgical correction of presbyopia still remains a significant challenge for refractive surgeons. Surgical strategies for dealing with presbyopia may be extraocular (corneal or scleral) or intraocular (removal and replacement of the crystalline lens or some type of treatment on the crystalline lens itself). There are however a number of limitations and considerations that have limited the widespread acceptance of surgical correction of presbyopia. Each surgical strategy presents its own unique set of advantages and disadvantages. For example, lens removal and replacement with an intraocular lens may not be preferable in a young patient with presbyopia without a refractive error. Similarly treatment on the crystalline lens may not be a suitable choice for a patient with early signs of cataract. This article is a review of the options available and those that are in development stages and are likely to be available in the near future for the surgical correction of presbyopia.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

High levels of corneal astigmatism are prevalent in a significant proportion of the population. During cataract surgery pre-existing astigmatism can be corrected using single or paired incisions on the steep axis of the cornea, using relaxing incisions or with the use of a toric intraocular lens. This review provides an overview of the conventional methods of astigmatic correction during cataract surgery and in particular, discusses the various types of toric lenses presently available and the techniques used in determining the correct axis for the placement of such lenses. Furthermore, the potential causes of rotation in toric lenses are identified, along with techniques for assessing and quantifying the amount of rotation and subsequent management options for addressing post-operative rotation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: Imaging of the crystalline lens and intraocular lens is becoming increasingly more important to optimize the refractive outcome of cataract surgery, to detect and manage complications and to ascertain advanced intraocular lens performance. This review examines recent advances in anterior segment imaging. RECENT FINDINGS: The main techniques used for imaging the anterior segment are slit-lamp biomicroscopy, ultrasound biomicroscopy, scheimpflug imaging, phakometry, optical coherence tomography and magnetic resonance imaging. They have principally been applied to the assessment of intraocular lens centration, tilt, position relative to the iris and movement with ciliary body contraction. SUMMARY: Despite the advances in anterior chamber imaging technology, there is still the need for a clinical, high-resolution, true anatomical, noninvasive technique to image behind the peripheral iris. © 2007 Lippincott Williams & Wilkins, Inc.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this thesis was to develop standards of best practice for the subjective assessment of near visual function in presbyopia. Near visual acuity (VA) is a quick and simple measure but an assessment of the maximum reading speed and the smallest print size that can maintain this are equally important, to gain a better reflection of real world visual function. These metrics are dependent on the amplitude of accommodation (AoA) and often this must be evaluated using subjective techniques. Defocus curves are less susceptible than the push-up/push-down test to the influence of blur tolerance but their implementation must be standardised such that letter sequences and the order of lens presentation are randomised, to avoid memory effects, whilst the AoA should be quantified as the range of defocus for which only the best VA is maintained. In addition to such clinical assessments, subjective questionnaire evaluations are also important, to determine whether at least an individual’s needs are met. The Near Activity Visual Questionnaire (NAVQ) developed in this thesis can be used for this. Using these standardised near vision metrics it is shown that visual performance with monovision and multifocal contact lenses is comparable whilst initial outcomes of single optic ‘accommodating’ intraocular lens implantation are unlikely to be sustained in the long-term.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The binding theme of this thesis is the examination of both phakic and pseudophakic accommodation by means of theoretical modelling and the application of a new biometric measuring technique. Anterior Segment Optical Coherence Tomography (AS-OCT) was used to assess phakic accommodative changes in 30 young subjects (19.4 2.0 years; range, 18 to 25 years). A new method of assessing curvature change with this technique was employed with limited success. Changes in axial accommodative spacing, however, proved to be very similar to those of the Scheimpflug-based data. A unique biphasic trend in the position of the posterior crystalline lens surface during accommodation was discovered, which has not been alluded to in the literature. All axial changes with accommodation were statistically significant (p < 0.01) with the exception of corneal thickness (p = 0.81). A two-year follow-up study was undertaken for a cohort of subjects previously implanted with a new accommodating intraocular lens (AIOL) (Lenstec Tetraflex KH3500). All measures of best corrected distance visual acuity (BCDVA; +0.04 0.24 logMAR), distance corrected near visual acuity (DCNVA; +0.61 0.17 logMAR) and contrast sensitivity (+1.35 0.21 log units) were good. The subjective accommodation response quantified with the push-up technique (1.53 0.64 D) and defocus curves (0.77 0.29 D) was greater than the objective stimulus response (0.21 0.19 D). AS-OCT measures with accommodation stimulus revealed a small mean posterior movement of the AIOLs (0.02 0.03 mm for a 4.0 D stimulus); this is contrary to proposed mechanism of the anterior focus-shift principle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As technology and medical devices improve, there is much interest in when and how astigmatism should be corrected with refractive surgery. Astigmatism can be corrected by most forms of refractive surgery, such as using excimer lasers algorithms to ablate the cornea to compensate for the magnitude of refractive error in different meridians. Correction of astigmatism at the time of cataract surgery is well developed and can be achieved through incision placement, relaxing incisions and toric intraocular lens (IOL) implantation. This was less of an issue in the past when there was a lower expectation to be spectacle independent after cataract surgery, in which case the residual refractive error, including astigmatism, could be compensated for with spectacle lenses. The issue of whether presurgical astigmatism should be corrected can be considered separately depending on whether a patient has residual accommodation, and the type of refractive surgery under consideration. We have previously reported on the visual impact of full correction of astigmatism, rather than just correcting the mean spherical equivalent. Correction of astigmatism as low as 1.00 dioptres significantly improves objective and subjective measures of functional vision in prepresbyopes at distance and near.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 ± 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was -0.13 ± 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of ±0.50 D. Mean uncorrected distance visual acuity was +0.10 ± 0.12 logMAR monocularly and 0.02 ± 0.09 logMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 ± 0.16 logMAR, improving to 0.15 ± 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 ± 0.11 logMAR, improving to 0.09 ± 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 ± 0.14 log units at 3 cycles per degree, 1.88 ± 0.20 log units at 6 cycles per degree, 1.66 ± 0.19 log units at 12 cycles per degree, and 1.11 ± 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 1° of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 ± 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision. © SLACK Incorporated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We assess the accuracy of the Visante anterior segment optical coherence tomographer (AS-OCT) and present improved formulas for measurement of surface curvature and axial separation. Measurements are made in physical model eyes. Accuracy is compared for measurements of corneal thickness (d1) and anterior chamber depth (d2) using-built-in AS-OCT software versus the improved scheme. The improved scheme enables measurements of lens thickness (d 3) and surface curvature, in the form of conic sections specified by vertex radii and conic constants. These parameters are converted to surface coordinates for error analysis. The built-in AS-OCT software typically overestimates (mean±standard deviation(SD)]d1 by +62±4 μm and d2 by +4±88μm. The improved scheme reduces d1 (-0.4±4 μm) and d2 (0±49 μm) errors while also reducing d3 errors from +218±90 (uncorrected) to +14±123 μm (corrected). Surface x coordinate errors gradually increase toward the periphery. Considering the central 6-mm zone of each surface, the x coordinate errors for anterior and posterior corneal surfaces reached +3±10 and 0±23 μm, respectively, with the improved scheme. Those of the anterior and posterior lens surfaces reached +2±22 and +11±71 μm, respectively. Our improved scheme reduced AS-OCT errors and could, therefore, enhance pre- and postoperative assessments of keratorefractive or cataract surgery, including measurement of accommodating intraocular lenses. © 2007 Society of Photo-Optical Instrumentation Engineers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intraocular light scatter is high in certain subject groups eg the elderly, due to increased optical media turbidity, which scatters and attenuates light travelling towards the retina. This causes reduced retinal contrast especially in the presence of glare light. Such subjects have depressed Contrast Sensitivity Functions (CSF). Currently available clinical tests do not effectively reflect this visual disability. Intraocular light scatter may be quantified by measuring the CSF with and without glare light and calculating Light Scatter Factors (LSF). To record the CSF on clinically available equipment (Nicolet CS2000), several psychophysical measurement techniques were investigated, and the 60 sec Method of Increasing Contrast was selected as the most appropriate. It was hypothesised that intraocular light scatter due to particles of different dimensions could be identified by glare sources at wide (30°) and narrow (3.5°) angles. CSFs andLSFs were determined for: (i) Subjects in young, intermediate and old age groups. (ii) Subjects during recovery from large amounts of induced corneal oedema. (iii) A clinical sample of contact lens (CL) wearers with a group of matched controls. The CSF was attenuated at all measured spatial frequencies with the intermediate and old group compared to the young group. High LSF values were found only in the old group (over 60 years). It was concluded that CSF attenuation in the intermediate group was due to reduced pupil size, media absorption and/or neural factors. In the old group, the additional factor was high intraocular light scatter levels of lenticular origin. The rate of reduction of the LSF for the 3.5° glare angle was steeper than that for the 30° angle, following induced corneal oedema. This supported the hypothesis, as it was anticipated that epithelial oedema would recover more rapidly than stromal oedema. CSFs and LSFs were markedly abnormal in the CL wearers. The analytical details and the value of these investigative techniques in contact lens research are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Premium intraocular lenses (IOLs) aim to surgically correct astigmatism and presbyopia following cataract extraction, optimising vision and eliminating the need for cataract surgery in later years. It is usual to fully correct astigmatism and to provide visual correction for distance and near when prescribing spectacles and contact lenses, however for correction with the lens implanted during cataract surgery, patients are required to purchase the premium IOLs and pay surgery fees outside the National Health Service in the UK. The benefit of using toric IOLs was thus demonstrated, both in standard visual tests and real-world situations. Orientation of toric IOLs during implantation is critical and the benefit of using conjunctival blood vessels for alignment was shown. The issue of centration of IOLs relative to the pupil was also investigated, showing changes with the amount of dilation and repeat dilation evaluation, which must be considered during surgery to optimize the visual performance of premium IOLs. Presbyopia is a global issue, of growing importance as life expectancy increases, with no real long-term cure. Despite enhanced lifestyles, changes in diet and improved medical care, presbyopia still presents in modern life as a significant visual impairment. The onset of presbyopia was found to vary with risk factors including alcohol consumption, smoking, UV exposure and even weight as well as age. A new technique to make measurement of accommodation more objective and robust was explored, although needs for further design modifications were identified. Due to dysphotopsia and lack of intermediate vision through most multifocal IOL designs, the development of a trifocal IOL was shown to minimize these aspects. The current thesis, therefore, emphasises the challenges of premium IOL surgery and need for refinement for optimum visual outcome in addition to outlining how premium IOLs may provide long-term and successful correction of astigmatism and presbyopia.