42 resultados para Induced Refractive Errors
Resumo:
Recent results on direct femtosecond inscription of straight low-loss waveguides in borosilicate glass are presented. We also demonstrate lowest ever losses in curvilinear waveguides, which we use as main building blocks for integrated photonics circuits. Low-loss waveguides are of great importance to a variety of applications of integrated optics. We report on recent results of direct femtosecond fabrication of smooth low-loss waveguides in standard optical glass by means of femtosecond chirped-pulse oscillator only (Scientific XL, Femtolasers), operating at the repetition rate of 11 MHz, at the wavelength of 800 nm, with FWHM pulse duration of about 50 fs, and a spectral widths of 30 nm. The pulse energy on target was up to 70 nJ. In transverse inscription geometry, we inscribed waveguides at the depth from 10 to 300 micrometers beneath the surface in the samples of 50 x 50 x 1 mm dimensions made of pure BK7 borosilicate glass. The translation of the samples accomplished by 2D air-bearing stage (Aerotech) with sub-micrometer precision at a speed of up to 100 mm per second (hardware limit). Third direction of translation (Z-, along the inscribing beam or perpendicular to sample plane) allows truly 3D structures to be fabricated. The waveguides were characterized in terms of induced refractive index contrast, their dimensions and cross-sections, mode-field profiles, total insertion losses at both 633 nm and 1550 nm. There was almost no dependence on polarization for the laser inscription. The experimental conditions – depth, laser polarization, pulse energy, translation speed and others, were optimized for minimum insertion losses when coupled to a standard optical fibre SMF-28. We found coincidence of our optimal inscription conditions with recently published by other groups [1, 3] despite significant difference in practically all experimental parameters. Using optimum regime for straight waveguides fabrication, we inscribed a set of curvilinear tracks, which were arranged in a way to ensure the same propagation length (and thus losses) and coupling conditions, while radii of curvature varied from 3 to 10 mm. This allowed us to measure bend-losses – they less than or about 1 dB/cm at R=10 mm radius of curvature. We also demonstrate a possibility to fabricate periodical perturbations of the refractive index in such waveguides with the periods using the same set-up. We demonstrated periods of about 520 nm, which allowed us to fabricate wavelength-selective devices using the same set-up. This diversity as well as very short time for inscription (the optimum translation speed was found to be 40 mm/sec) makes our approach attractive for industrial applications, for example, in next generation high-speed telecom networks.
Resumo:
Golfers, coaches and researchers alike, have all keyed in on golf putting as an important aspect of overall golf performance. Of the three principle putting tasks (green reading, alignment and the putting action phase), the putting action phase has attracted the most attention from coaches, players and researchers alike. This phase includes the alignment of the club with the ball, the swing, and ball contact. A significant amount of research in this area has focused on measuring golfer’s vision strategies with eye tracking equipment. Unfortunately this research suffers from a number of shortcomings, which limit its usefulness. The purpose of this thesis was to address some of these shortcomings. The primary objective of this thesis was to re-evaluate golfer’s putting vision strategies using binocular eye tracking equipment and to define a new, optimal putting vision strategy which was associated with both higher skill and success. In order to facilitate this research, bespoke computer software was developed and validated, and new gaze behaviour criteria were defined. Additionally, the effects of training (habitual) and competition conditions on the putting vision strategy were examined, as was the effect of ocular dominance. Finally, methods for improving golfer’s binocular vision strategies are discussed, and a clinical plan for the optometric management of the golfer’s vision is presented. The clinical management plan includes the correction of fundamental aspects of golfers’ vision, including monocular refractive errors and binocular vision defects, as well as enhancement of their putting vision strategy, with the overall aim of improving performance on the golf course. This research has been undertaken in order to gain a better understanding of the human visual system and how it relates to the sport performance of golfers specifically. Ultimately, the analysis techniques and methods developed are applicable to the assessment of visual performance in all sports.
Resumo:
Recent results on direct femtosecond inscription of straight low-loss waveguides in borosilicate glass are presented. We also demonstrate lowest ever losses in curvilinear waveguides, which we use as main building blocks for integrated photonics circuits. Low-loss waveguides are of great importance to a variety of applications of integrated optics. We report on recent results of direct femtosecond fabrication of smooth low-loss waveguides in standard optical glass by means of femtosecond chirped-pulse oscillator only (Scientific XL, Femtolasers), operating at the repetition rate of 11 MHz, at the wavelength of 800 nm, with FWHM pulse duration of about 50 fs, and a spectral widths of 30 nm. The pulse energy on target was up to 70 nJ. In transverse inscription geometry, we inscribed waveguides at the depth from 10 to 300 micrometers beneath the surface in the samples of 50 x 50 x 1 mm dimensions made of pure BK7 borosilicate glass. The translation of the samples accomplished by 2D air-bearing stage (Aerotech) with sub-micrometer precision at a speed of up to 100 mm per second (hardware limit). Third direction of translation (Z-, along the inscribing beam or perpendicular to sample plane) allows truly 3D structures to be fabricated. The waveguides were characterized in terms of induced refractive index contrast, their dimensions and cross-sections, mode-field profiles, total insertion losses at both 633 nm and 1550 nm. There was almost no dependence on polarization for the laser inscription. The experimental conditions – depth, laser polarization, pulse energy, translation speed and others, were optimized for minimum insertion losses when coupled to a standard optical fibre SMF-28. We found coincidence of our optimal inscription conditions with recently published by other groups [1, 3] despite significant difference in practically all experimental parameters. Using optimum regime for straight waveguides fabrication, we inscribed a set of curvilinear tracks, which were arranged in a way to ensure the same propagation length (and thus losses) and coupling conditions, while radii of curvature varied from 3 to 10 mm. This allowed us to measure bend-losses – they less than or about 1 dB/cm at R=10 mm radius of curvature. We also demonstrate a possibility to fabricate periodical perturbations of the refractive index in such waveguides with the periods using the same set-up. We demonstrated periods of about 520 nm, which allowed us to fabricate wavelength-selective devices using the same set-up. This diversity as well as very short time for inscription (the optimum translation speed was found to be 40 mm/sec) makes our approach attractive for industrial applications, for example, in next generation high-speed telecom networks.
Resumo:
A transversal-load sensor based on the local pressure-induced refractive index change in a chirped fiber Bragg grating (CFBG) is proposed. The local pressure induced refractive index change in the touch point can generate a main transmission peak and several subpeaks on the long wavelength side of the reflection band of the CFBG. The difference of the wavelength shifts for the main transmission peak and the first subpeak is used to measure transversal-load with temperature compensation capability.
Resumo:
Aim: Theoretically myopes are required to exert more accommodation and vergence when wearing single vision contact lenses compared to glasses and hypermetropes less. This study aims to quantify the effects clinically. Method: Thirty subjects (21 female, nine male, average age 21.0 ± 2.2 years) with a range of refractive errors (-7.87 D to +3.50 D) viewed in a random order, static targets at 0.1, 0.5, 1.0, 2.0, 3.0, 4.0 and 5.0 D accommodative demand that were matched for angular subtense. The subjects were fully corrected with spectacles and daily disposable contact lenses to their full prescription. Accommodation was monitored objectively with the PowerRefractor and Shin-Nippon SRW5000 and vergence and pupil size with the PowerRefractor. Results: Myopes exerted greater accommodative effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.35, p = 0.001 PowerRefractor). Myopes also exerted greater vergence effort for viewing near targets with contact lenses than glasses and hypermetropes less (r2 = 0.22, p < 0.01). Conclusion: Theoretical calculation of the accommodative and vergence requirements with glasses compared to contact lenses reflect clinical findings, although there is reasonable variability between individuals. © 2006 British Contact Lens Association.
Resumo:
We report that the main photosensitive mechanism of poly(methyl methacrylate)-based optical fiber Bragg grating (POFBG) under ultraviolet laser micromachining is a complex process of both photodegradation and negative thermo-optic effect. We found experimentally the unique characteristics of Bragg resonance splitting and reunion during the laser micromachining process providing the evidence of photodegradation, while the mean refractive index change of POFBG was measured to be negative confirming further photodegradation of polymer fiber. The thermal-induced refractive index change of POFBG was also observed by recording the Bragg wavelength shift. Furthermore, the dynamic thermal response of the micromachined-POFBG was demonstrated under constant humidity, showing a linear and negative response of around -47.1 pm/°C.
Resumo:
Purpose: Several studies have suggested accommodative lags may serve as a stimulus for myopic growth, and while a blurred foveal image is believed to the main stimulus for accommodation, spectral composition of the retinal image is also believed to influence accommodative accuracy. Of particular interest is how altering spectral lighting conditions influences accommodation in the presence of soft multifocal contact lenses, which are currently being used off-label for myopia control. Methods: Accommodative responses were assessed using a Grand Seiko WAM-5500 autorefractor for four target distances: 25, 33, 50, and 100cm for 30 young adult subjects (14 myopic, 16 emmetropic; mean refractive errors (±SD, D) -4.22±2.04 and -0.15±0.67 respectively). Measurements were obtained with four different soft contact lenses, Single vision distance (SVD), Single vision near (SVN), Centre-Near (CN) and Centre-Distance (CD) (+1.50 add), and three different lighting conditions: red (peak λ 632nm), blue (peak λ 460nm), and white (peak λ 560nm). Corrections for chromatic differences in refraction were made prior to calculating accommodative errors. Results: The size of accommodative errors was significantly affected by lens design (p<0.001), lighting (p=0.027), and target distance (p=0.009). Mean accommodative errors were significantly larger with the SV lenses compared to the CD and CN designs (p<0.001). Errors were also significantly larger under blue light compared to white (p=0.004) and a significant interaction noted between lens design and lighting (p<0.001). Blue light generally decreased accommodative lags and increased accommodative leads relative to white and red light, the opposite was true of red light (p≤0.001). Lens design also significantly influenced direction of accommodative error (i.e. lag or lead) (p<0.001). Interactions with or between refractive groups were not found to be statistically significant for either the magnitude or direction of accommodative error (p>0.05 for all). Conclusions: Accuracy of accommodation is affected by both lens design and by wavelength of lighting. These accommodative lag data lend some support to recent speculation about the potential therapeutic value of lighting with a spectral bias towards blue during near work for myopia, although such treatment effects are likely to be more subtle under broad compared to the narrow spectrum lighting conditions used here.
Resumo:
Purpose: To evaluate the effects of instrument realignment and angular misalignment during the clinical determination of wavefront aberrations by simulation in model eyes. Setting: Aston Academy of Life Sciences, Aston University, Birmingham, United Kingdom. Methods: Six model eyes were examined with wavefront-aberration-supported cornea ablation (WASCA) (Carl Zeiss Meditec) in 4 sessions of 10 measurements each: sessions 1 and 2, consecutive repeated measures without realignment; session 3, realignment of the instrument between readings; session 4, measurements without realignment but with the model eye shifted 6 degrees angularly. Intersession repeatability and the effects of realignment and misalignment were obtained by comparing the measurements in the various sessions for coma, spherical aberration, and higher-order aberrations (HOAs). Results: The mean differences between the 2 sessions without realignment of the instrument were 0.020 μm ± 0.076 (SD) for Z3 - 1(P = .551), 0.009 ± 0.139 μm for Z3 1(P = .877), 0.004 ± 0.037 μm for Z4 0 (P = .820), and 0.005 ± 0.01 μm for HO root mean square (RMS) (P = .301). Differences between the nonrealigned and realigned instruments were -0.017 ± 0.026 μm for Z3 - 1(P = .159), 0.009 ± 0.028 μm for Z3 1 (P = .475), 0.007 ± 0.014 μm for Z4 0(P = .296), and 0.002 ± 0.007 μm for HO RMS (P = 0.529; differences between centered and misaligned instruments were -0.355 ± 0.149 μm for Z3 - 1 (P = .002), 0.007 ± 0.034 μm for Z3 1(P = .620), -0.005 ± 0.081 μm for Z4 0(P = .885), and 0.012 ± 0.020 μm for HO RMS (P = .195). Realignment increased the standard deviation by a factor of 3 compared with the first session without realignment. Conclusions: Repeatability of the WASCA was excellent in all situations tested. Realignment substantially increased the variance of the measurements. Angular misalignment can result in significant errors, particularly in the determination of coma. These findings are important when assessing highly aberrated eyes during follow-up or before surgery. © 2007 ASCRS and ESCRS.
Resumo:
Purpose. Whereas many previous studies have identified the association between sustained near work and myopia, few have assessed the influence of concomitant levels of cognitive effort. This study investigates the effect of cognitive effort on near-work induced transient myopia (NITM). Methods. Subjects comprised of six early onset myopes (EOM; mean age 23.7 yrs; mean onset 10.8 yrs), six late-onset myopes (LOM; mean age 23.2 yrs; mean onset 20.0 yrs) and six emmetropes (EMM; mean age 23.8 yrs). Dynamic, monocular, ocular accommodation was measured with the Shin-Nippon SRW-5000 autorefractor. Subjects engaged passively or actively in a 5 minute arithmetic sum checking task presented monocularly on an LCD monitor via a Badal optical system. In all conditions the task was initially located at near (4.50 D) and immediately following the task instantaneously changed to far (0.00 D) for a further 5 minutes. The combinations of active (A) and passive (P) cognition were randomly allocated as P:P; A:P; A:A; P:A. Results. For the initial near task, LOMs were shown to have a significantly less accurate accommodative response than either EOMs or EMMs (p < 0.001). For the far task, post hoc analyses for refraction identified EOMs as demonstrating significant NITM compared to LOMs (p < 0.05), who in turn showed greater NITM than EMMs (p < 0.001). The data show that for EOMs the level of cognitive activity operating during the near and far tasks determines the persistence of NITM; persistence being maximal when active cognition at near is followed by passive cognition at far. Conclusions. Compared with EMMs, EOMs and LOMs are particularly susceptible to NITM such that sustained near vision reduces subsequent accommodative accuracy for far vision. It is speculated that the marked NITM found in EOM may be a consequence of the crystalline lens thinning shown to be a developmental feature of EOM. Whereas the role of small amounts of retinal defocus in myopigenesis remains equivocal, the results show that account needs to be taken of cognitive demand in assessing phenomena such as NITM.
Resumo:
The distinct behaviour of femtosecond laser inscribed long period gratings, with a non-uniform index perturbation within the optical fibre core, has been studied experimentally. The non-uniform laser-induced perturbation results in light coupling from the core mode to a greater number of cladding modes than is the case with their UV laser inscribed counterparts, and this is made evident from the surrounding refractive index (SRI) grating response. Femtosecond inscribed long period gratings are shown to simultaneously couple to multiple sets of cladding modes. A 400μm LPG is shown to result in attenuation peaks that have both blue and red wavelength shifts over a 1250nm to 1700nm wavelength range. This gives rise to SRI sensitivities far greater than anything achievable by monitoring a single attenuation peak. The maximum sensitivity produced by monitoring a single attenuation peak was 1106nm/RIU, whereas monitoring opposing wavelength shifts resulted in a significantly improved sensitivity of 1680nm/RIU. © 2011 Copyright Society of Photo-Optical Instrumentation Engineers (SPIE).
Resumo:
Long-period fibre gratings (LPGs) have previously been used to detect quantities such as temperature, strain and refractive index (RI). The responsivity to surrounding refractive index means that, potentially, LPGs could be realised as optical biosensors for applications in biochemical and biomedical application areas. We report here to our best knowledge the first investigation on refractive index sensing properties of LPGs with sol-gel derived titanium and silicon oxide coatings. It is revealed that the RI sensitivity of an LPG is affected by both the thickness and the index value of the coating; the coating with higher index and thickness will enhance the LPG RI sensitivity significantly. The surrounding refractive index induced LPG resonance shift has been evaluated over the LPGs’ most sensitive RI region from 1.42 to 1.44. We have identified that, in this region, the uncoated LPG has an RI sensitivity of (-673.0±0.4)nm/uri (unit of refractive index) while the LPG coated with titanium oxide exhibits a sensitivity as high as (-1067.15±0.04)nm/uri.
Resumo:
In this work, a microchanneled chirped fiber Bragg grating (MCFBG) is proposed and fabricated through the femtosecond laser-assisted chemical etching. The microchannel (~550 µm) gives access to the external index liquid, thus inducing refractive index (RI) sensitivity to the structure. In the experiment, the transmission bands induced by the reduced effective index in the microchannel region were used to sense the surrounding RI and temperature changes. The experimental results show good agreement with the theoretical analysis. The proposed MCFBG offers enhanced RI sensitivity without degrading the robustness of the device showing good application potential as bio-chemical sensors.
Resumo:
Reported are experimental results from investigations of the sensing properties of long-period gratings (LPGs) recorded in two different geometries of photonic crystal fibre (PCF): a large-mode area PCF and an endlessly single mode PCF. The LPGs have been characterised for their sensitivity to temperature, bending, surrounding index and strain. The LPGs in both fibres have been found to have negligible temperature sensitivity whilst exhibiting useful strain sensitivities. Strong directional bend sensitivity is shown by one PCF whilst the other shows good non-directional bend sensitivity. The fibres exhibit differing sensitivities to surrounding refractive index.
Resumo:
Long-period fibre gratings (LPGs) have previously been used to detect quantities such as temperature, strain, and refractive index (RI). We report here, to the best of our knowledge, the first investigation on refractive index sensing properties of LPGs with sol–gel derived titanium and silicon oxide coatings. It is revealed that the RI sensitivity of an LPG is affected by both the thickness and the index value of the coating; a coating with higher index and thickness will enhance the LPG RI sensitivity significantly. The surrounding refractive index induced LPG resonance shift has been evaluated over the LPGs' most sensitive RI region from 1.42 to 1.44. We have identified that, in this region, the uncoated LPG has an RI sensitivity of (-673.0 ± 0.4) nm/uri (unit of refractive index) while the LPG coated with titanium oxide exhibits a sensitivity as high as (-1067.15 ± 0.04) nm/uri. The experimental results also reveal that, even in the RI insensitive region around 1.33, there still is a marked enhancement in RI sensitivity of the sol–gel coated LPG compared to the uncoated one. This is potentially significant as coated LPGs may be extended to low RI gas and semi-liquidized based sensing applications.
Resumo:
The microchannelled chirped fibre Bragg grating (MCFBG) was fabricated using femtosecond laser processing and HF-etching. Intrinsical refractive-index sensitivity induced by the microchannel makes MCFBGs ideal for biochemical sensing.