33 resultados para Gestural interface
Resumo:
The present scarcity of operational knowledge-based systems (KBS) has been attributed, in part, to an inadequate consideration shown to user interface design during development. From a human factors perspective the problem has stemmed from an overall lack of user-centred design principles. Consequently the integration of human factors principles and techniques is seen as a necessary and important precursor to ensuring the implementation of KBS which are useful to, and usable by, the end-users for whom they are intended. Focussing upon KBS work taking place within commercial and industrial environments, this research set out to assess both the extent to which human factors support was presently being utilised within development, and the future path for human factors integration. The assessment consisted of interviews conducted with a number of commercial and industrial organisations involved in KBS development; and a set of three detailed case studies of individual KBS projects. Two of the studies were carried out within a collaborative Alvey project, involving the Interdisciplinary Higher Degrees Scheme (IHD) at the University of Aston in Birmingham, BIS Applied Systems Ltd (BIS), and the British Steel Corporation. This project, which had provided the initial basis and funding for the research, was concerned with the application of KBS to the design of commercial data processing (DP) systems. The third study stemmed from involvement on a KBS project being carried out by the Technology Division of the Trustees Saving Bank Group plc. The preliminary research highlighted poor human factors integration. In particular, there was a lack of early consideration of end-user requirements definition and user-centred evaluation. Instead concentration was given to the construction of the knowledge base and prototype evaluation with the expert(s). In response to this identified problem, a set of methods was developed that was aimed at encouraging developers to consider user interface requirements early on in a project. These methods were then applied in the two further projects, and their uptake within the overall development process was monitored. Experience from the two studies demonstrated that early consideration of user interface requirements was both feasible, and instructive for guiding future development work. In particular, it was shown a user interface prototype could be used as a basis for capturing requirements at the functional (task) level, and at the interface dialogue level. Extrapolating from this experience, a KBS life-cycle model is proposed which incorporates user interface design (and within that, user evaluation) as a largely parallel, rather than subsequent, activity to knowledge base construction. Further to this, there is a discussion of several key elements which can be seen as inhibiting the integration of human factors within KBS development. These elements stem from characteristics of present KBS development practice; from constraints within the commercial and industrial development environments; and from the state of existing human factors support.
Resumo:
Presentation Abstract - Purpose:Serial intravitreal ranibizumab injections are the main treatment for wet age- related macular degeneration (AMD), and patients are monitored by optical coherence tomography (OCT). Our objective in conducting this study is to determine whether serial intravitreal injections of ranibizumab in eyes with wet AMD alter the vitreo-macular interface (VMI) Methods - Using a Topcon Spectral Domain OCT, we performed a prospective, observational study of 87 eyes of 82 consecutive patients undergoing treatment with intravitreal ranibizumab for wet AMD, with each patient followed up for a minimum of 6 months. The mean number of intravitreal ranibizumab injections was 4.28, range 3-6. Using macular OCT scans, the area of VMI was closely examined, for vitreo-macular adhesion (VMA), defined as perifoveal posterior vitreous detachment (PVD) with posterior vitreous attached to fovea. Any OCT separation of posterior vitreous face was observed and measured, every month for 6 months. Results - There was no change in the OCT appearance or measurement of VM interface in 80 eyes (92%). VM adhesion, defined on OCT as when the posterior hyaloid line is attached to inner foveal surface and dettached perifoveally, was identified in 7 out of 87 treated eyes (8%) .Of these 7 eyes, 1 eye developed complete PVD following three injections, 1 eye developed partial PVD and the remaining 5 eyes had no significant change in VM adhesion. Conclusions - To our knowledge this is the first study that has examined the VM interface following serial ranibizumab injections for wet AMD. This small pilot study suggests that most cases undergoing ranibizumab therapy suffer no disturbance to VM interface.
Resumo:
We investigated which evoked response component occurring in the first 800 ms after stimulus presentation was most suitable to be used in a classical P300-based brain-computer interface speller protocol. Data was acquired from 275 Magnetoencephalographic sensors in two subjects and from 61 Electroencephalographic sensors in four. To better characterize the evoked physiological responses and minimize the effect of response overlap, a 1000 ms Inter Stimulus Interval was preferred to the short (
Resumo:
Using the resistance literature as an underpinning theoretical framework, this chapter analyzes how Web designers through their daily practices, (i) adopt recursive, adaptive, and resisting behavior regarding the inclusion of social cues online and (ii) shape the socio-technical power relationship between designers and other stakeholders. Five vignettes in the form of case studies with expert individual Web designers are used. Findings point out at three types of emerging resistance namely: market driven resistance, ideological resistance, and functional resistance. In addition, a series of propositions are provided linking the various themes. Furthermore, the authors suggest that stratification in Web designers’ type is occurring and that resistance offers a novel lens to analyze the debate.
Resumo:
Human leukocyte antigen (HLA)-DM is a critical participant in antigen presentation that catalyzes the dissociation of the Class II-associated Invariant chain-derived Peptide (CLIP) from the major histocompatibility complex (MHC) Class II molecules. There is competition amongst peptides for access to an MHC Class II groove and it has been hypothesised that DM functions as a 'peptide editor' that catalyzes the replacement of one peptide for another within the groove. It is established that the DM catalyst interacts directly with the MHC Class II but the precise location of the interface is unknown. Here, we combine previously described mutational data with molecular docking and energy minimisation simulations to identify a putative interaction site of >4000A2 which agrees with known point mutational data for both the DR and DM molecule. The docked structure is validated by comparison with experimental data and previously determined properties of protein-protein interfaces. A possible dissociation mechanism is suggested by the presence of an acidic cluster near the N terminus of the bound peptide.
Resumo:
In recent years, mobile technology has been one of the major growth areas in computing. Designing the user interface for mobile applications, however, is a very complex undertaking which is made even more challenging by the rapid technological developments in mobile hardware. Mobile human-computer interaction, unlike desktop-based interaction, must be cognizant of a variety of complex contextual factors affecting both users and technology. The Handbook of Research on User Interface Design and Evaluation provides students, researchers, educators, and practitioners with a compendium of research on the key issues surrounding the design and evaluation of mobile user interfaces, such as the physical environment and social context in which a mobile device is being used and the impact of multitasking behavior typically exhibited by mobile-device users. Compiling the expertise of over 150 leading experts from 26 countries, this exemplary reference tool will make an indispensable addition to every library collection.
Resumo:
The semantic web (SW) vision is one in which rich, ontology-based semantic markup will become widely available. The availability of semantic markup on the web opens the way to novel, sophisticated forms of question answering. AquaLog is a portable question-answering system which takes queries expressed in natural language (NL) and an ontology as input, and returns answers drawn from one or more knowledge bases (KB). AquaLog presents an elegant solution in which different strategies are combined together in a novel way. AquaLog novel ontology-based relation similarity service makes sense of user queries.
Resumo:
The Teallach project has adapted model-based user-interface development techniques to the systematic creation of user-interfaces for object-oriented database applications. Model-based approaches aim to provide designers with a more principled approach to user-interface development using a variety of underlying models, and tools which manipulate these models. Here we present the results of the Teallach project, describing the tools developed and the flexible design method supported. Distinctive features of the Teallach system include provision of database-specific constructs, comprehensive facilities for relating the different models, and support for a flexible design method in which models can be constructed and related by designers in different orders and in different ways, to suit their particular design rationales. The system then creates the desired user-interface as an independent, fully functional Java application, with automatically generated help facilities.
Resumo:
A simple method of creating defined PMMA and poly (MMA-co-Cz) electrocoatings on carbon fibres is described. The electrodeposition of poly methylmethacrylate (PMMA) onto unsized, unmodified carbon fibres was performed by simple constant current electrolyses of methylmethacrylate (MMA) monomer in dimethylformamide (DMF) solutions and the 'pur' liquid monomer using sodium nitrate and lithium perchlorate as supporting electrolytes. The presence of polymeric coatings successfully attached to the carbon fibres was verified by scanning electron microscopy and photoelectron spectroscopy (XPS). Performing the electrolysis in dilute MMA in DMF solutions ([MMA]
Resumo:
Ultrathin Fe oxide films of various thicknesses prepared by post-growth oxidation on GaAs(100) surface have been investigated with X-ray photoelectron spectroscopy (XPS), X-ray absorption spectroscopy (XAS), and X-ray magnetic circular dichroism (XMCD). The XPS confirms that the surfaces of the oxide are Fe3O4 rather than Fe2O3. XAS and XMCD measurements indicate the presence of insulating Fe divalent oxide phases (FeO) beneath the surface Fe3O4 layer with the sample thickness above 4 nm. This FeO might act as a barrier for the spin injection into the GaAs.
Resumo:
Audio feedback remains little used in most graphical user interfaces despite its potential to greatly enhance interaction. Not only does sonic enhancement of interfaces permit more natural human-computer communication but it also allows users to employ an appropriate sense to solve a problem rather than having to rely solely on vision. Research shows that designers do not typically know how to use sound effectively; subsequently, their ad hoc use of sound often leads to audio feedback being considered an annoying distraction. Unlike the design of purely graphical user interfaces for which guidelines are common, the audio-enhancement of graphical user interfaces has (until now) been plagued by a lack of suitable guidance. This paper presents a series of empirically substantiated guidelines for the design and use of audio-enhanced graphical user interface widgets.