17 resultados para Endoscopy, gastrointestinal


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To develop a tool for the accurate reporting and aggregation of findings from each of the multiple methods used in a complex evaluation in an unbiased way. Study Design and Setting: We developed a Method for Aggregating The Reporting of Interventions in Complex Studies (MATRICS) within a gastroenterology study [Evaluating New Innovations in (the delivery and organisation of) Gastrointestinal (GI) endoscopy services by the NHS Modernisation Agency (ENIGMA)]. We subsequently tested it on a different gastroenterology trial [Multi-Institutional Nurse Endoscopy Trial (MINuET)]. We created three layers to define the effects, methods, and findings from ENIGMA. We assigned numbers to each effect in layer 1 and letters to each method in layer 2. We used an alphanumeric code based on layers 1 and 2 to every finding in layer 3 to link the aims, methods, and findings. We illustrated analogous findings by assigning more than one alphanumeric code to a finding. We also showed that more than one effect or method could report the same finding. We presented contradictory findings by listing them in adjacent rows of the MATRICS. Results: MATRICS was useful for the effective synthesis and presentation of findings of the multiple methods from ENIGMA. We subsequently successfully tested it by applying it to the MINuET trial. Conclusion: MATRICS is effective for synthesizing the findings of complex, multiple-method studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Opto-acoustic imaging is a growing field of research in recent years, providing functional imaging of physiological biomarkers, such as the oxygenation of haemoglobin. Piezo electric transducers are the industry standard detector for ultrasonics, but their limited bandwidth, susceptibility to electromagnetic interference and their inversely proportional sensitivity to size all affect the detector performance. Sensors based on polymer optical fibres (POF) are immune to electromagnetic interference, have lower acoustic impedance and a reduced Young's Modulus compared to silica fibres. Furthermore, POF enables the possibility of a wideband sensor and a size appropriate to endoscopy. Micro-structured POF (mPOF) used in an interferometric detector has been shown to be an order of magnitude more sensitive than silica fibre at 1 MHz and 3 times more sensitive at 10 MHz. We present the first opto-acoustic measurements obtained using a 4.7mm PMMA mPOF Bragg grating with a fibre diameter of 130 μm and present the lateral directivity pattern of a PMMA mPOF FBG ultrasound sensor over a frequency range of 1-50 MHz. We discuss the impact of the pattern with respect to the targeted application and draw conclusions on how to mitigate the problems encountered.