32 resultados para Electrode array


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The channelled spectrum of an optical beam generated by a laser diode operated below threshold after traversing microscope glass plates is spectrally analysed using a grating and a CCD linear array. The experiment has the following goals: to display the resulting channelled spectrum, to familiarize students with an important topic in metrology and to illustrate some interesting topics from spectroscopy using a CCD array as a spectrometer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present what is to our knowledge the first comprehensive investigation of the use of blazed fiber Bragg gratings (BFBGs) to interrogate wavelength division multiplexed (WDM) in-fiber optical sensor arrays. We show that the light outcoupled from the core of these BFBGs is radiated with sufficient optical power that it may be detected with a low-cost charge-coupled device (CCD) array. We present thorough system performance analysis that shows sufficient spectral-spatial resolution to decode sensors with a WDM separation of 75 ρm, signal-to-noise ratio greater than 45-dB bandwidth of 70 nm, and drift of only 0.1 ρm. We show the system to be polarization-state insensitive, making the BFBG-CCD spectral analysis technique a practical, extremely low-cost, alternative to traditional tunable filter approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Preliminary results are given for a long period grating sensing array scheme based upon a derivative spectroscopy interrogation technique for Human Respiratory Plethysmography with simultaneous measurements of a spirometer, reasonable agreement with recorded volumetric changes was found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, multiplexed sensor network capable of monitoring the shape changes of the torso for respiratory function monitoring is developed. As a demonstration, LPGs written into refractive index insensitive, progressive three layered fibre are embedded into supporting material is then placed on a resuscitation training manikin simulating respiration. A derivative spectroscopy interrogation technique is implemented and the bend sensitivity of the LPGs is used to reconstruct the shape of the manikin's torso. © 2003 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the development of a WDM optical sensor array interrogation system using the radiation modes from a BFBG. We present results indicating 70nm bandwidth, with 0.2um RMS noise and a minimum WDM spacing of 30um. We further show the system to be polarization independent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have investigated information transmission in an array of threshold units that have signal-dependent noise and a common input signal. We demonstrate a phenomenon similar to stochastic resonance and suprathreshold stochastic resonance with additive noise and show that information transmission can be enhanced by a nonzero level of noise. By comparing system performance to one with additive noise we also demonstrate that the information transmission of weak signals is significantly better with signal-dependent noise. Indeed, information rates are not compromised even for arbitrary small input signals. Furthermore, by an appropriate selection of parameters, we observe that the information can be made to be (almost) independent of the level of the noise, thus providing a robust method of transmitting information in the presence of noise. These result could imply that the ability of hair cells to code and transmit sensory information in biological sensory systems is not limited by the level of signal-dependent noise. © 2007 The American Physical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate a bi-metal coated (platinum and gold or silver), localized surface plasmon resonance fiber sensor with an index sensitivity exceeding 11,900 nm/RIU, yielding an index resolution of 2 × 10-5 in the aqueous index regime. This is one of the highest index sensitivities achieved with an optical fiber sensor. The coatings consist of arrays of bi-metal nano-wires (typically 36 nm in radius and 20 μm in length), supported by a silicon dioxide thin film on a thin substrate of germanium, the nano-wires being perpendicular to the longitudinal axis of the D-shaped fiber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibre Bragg Grating (FBG) array sensors have been successfully embedded in aluminium alloy matrix by ultrasonic consolidation (UC) technique. The temperature and loading responses of the embedded FBG arrays have been systematically characterised. The embedded grating sensors exhibit an average temperature sensitivity of ~36pm/°C, which is three times higher than that of normal FBGs, and a loading responsivity of ~0.1nm/kg within the dynamic range from 0kg to 3kg. This initial experiment clearly demonstrates that FBG array sensors can be embedded in metal matrix together with other passive and active fibres to fabricate smart materials to monitor the operation and health of engineering structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optical fibre strain sensors using Fibre Bragg Gratings (FBGs) are poised to play a major role in structural health monitoring in a variety of application from aerospace to civil engineering. At the heart of technology is the optoelectronic instrumentation required to convert optical signals into measurands. Users are demanding compact, lightweight, rugged and low cost solutions. This paper describes development of a new device based on a blazed FBG and CCD array that can potentially meet the above demands. We have shown that this very low cost technique may be used to interrogate a WDM array of sensor gratings with highly accurate and highly repeatable results unaffected by the polarisation state of the radiation. In this paper, we present results showing that sensors may be interrogated with an RMS error of 1.7pm, drift below 0.12pm and dynamic range of up to 65nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Electrosurgery units are widely employed in modern surgery. Advances in technology have enhanced the safety of these devices, nevertheless, accidental burns are still regularly reported. This study focuses on possible causes of sacral burns as complication of the use of electrosurgery. Burns are caused by local densifications of the current, but the actual pathway of current within patient's body is unknown. Numerical electromagnetic analysis can help in understanding the issue. Methods: To this aim, an accurate heterogeneous model of human body (including seventy-seven different tissues), electrosurgery electrodes, operating table and mattress was build to resemble a typical surgery condition. The patient lays supine on the mattress with the active electrode placed onto the thorax and the return electrode on his back. Common operating frequencies of electrosurgery units were considered. Finite Difference Time Domain electromagnetic analysis was carried out to compute the spatial distribution of current density within the patient's body. A differential analysis by changing the electrical properties of the operating table from a conductor to an insulator was also performed. Results: Results revealed that distributed capacitive coupling between patient body and the conductive operating table offers an alternative path to the electrosurgery current. The patient's anatomy, the positioning and the different electromagnetic properties of tissues promote a densification of the current at the head and sacral region. In particular, high values of current density were located behind the sacral bone and beneath the skin. This did not occur in the case of non-conductive operating table. Conclusion: Results of the simulation highlight the role played from capacitive couplings between the return electrode and the conductive operating table. The concentration of current density may result in an undesired rise in temperature, originating burns in body region far from the electrodes. This outcome is concordant with the type of surgery-related sacral burns reported in literature. Such burns cannot be immediately detected after surgery, but appear later and can be confused with bedsores. In addition, the dosimetric analysis suggests that reducing the capacity coupling between the return electrode and the operating table can decrease or avoid this problem. © 2013 Bifulco et al.; licensee BioMed Central Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel modulator array integrating eight GaAs electro-optic IQ modulators is characterized and tested over long-reach direct-detected multi-band OFDM-PONs. The GaAs IQ modulators present > 22 GHz bandwidth with 3V Vpi, being suitable for a 100-km 40-Gb/s OOFDM-PON supporting up to 1024 users.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive liquid level monitoring system based on microstructured polymer optical fiber Bragg grating (mPOFBG) array sensors is reported for the first time. The configuration is based on five mPOFBGs inscribed in the same fiber in the 850 nm spectral region, showing the potential to interrogate liquid level by measuring the strain induced in each mPOFBG embedded in a silicone rubber (SR) diaphragm, which deforms due to hydrostatic pressure variations. The sensor exhibits a highly linear response over the sensing range, a good repeatability, and a high resolution. The sensitivity of the sensor is found to be 98 pm/cm of water, enhanced by more than a factor of 9 when compared to an equivalent sensor based on a silica fiber around 1550 nm. The temperature sensitivity is studied and a multi-sensor arrangement proposed, which has the potential to provide level readings independent of temperature and the liquid density.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate if magnetoencephalography (MEG) can identify implantation sites for intracranial recordings (IR). Method: Two groups of 12 patients assessed for surgery with IR with and without MEG were compared (MEG and control groups). In the control group, non-invasive presurgical assessment without MEG suggested clear hypotheses for implantation. In the MEG group, non-invasive assessment was inconclusive, and MEG was used to identify implantation sites. Both groups were matched for implantation type. The success of implantation was defined by findings in IR: a) Focal seizure onset; b)Unilateral focal abnormal responses to single pulse electrical stimulation(SPES); and c) Concordance between a) and b). Results: In all MEG patients, at least one virtual MEG electrode generated suitable hypotheses for the location of implantations. The proportion of patients showing focal seizure onset restricted to one hemisphere was similar in control and MEG groups (6/12 vs. 11/12, Fisher’s exact test,p = 0.0686). The proportion of patients showing unilateral responses to SPES was lower in the control than in the MEG group (7/12 vs. 12/12,p = 0.0373). Conclusion: The MEG group showed similar or higher incidence of successful implantations than controls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, two linear coplanar array antennas based on Indium Phosphide (InP) substrate are designed, presented and compared in terms of bandwidth and gain. Slot introduction in combination with coplanar structure is investigated, providing enhanced antenna gain and bandwidth at the 60 GHz frequency band. In addition the proposed array antennas are evaluated in terms of integration with a high-speed photodiode and investigated in terms of matching, providing a bandwidth that reaches 2 GHz. Moreover a potential beam forming scenario combined with photonic up-conversion scheme has been proposed. © 2013 IEEE.