22 resultados para Cluster Analysis of Variables
Resumo:
Pulsed field gel electrophoresis of 82 intestinal spirochaete isolates showed specific differentiation of Serpulina pilosicoli and Serpulina hyodysenteriae although considerable heterogeneity was observed, especially amongst S. pilosicoli isolates. In several cases genotypically similar isolates originated from different animals suggesting that cross-species transmission may have occurred. The Caco-2 and Caco-21HT29 cell models have been proposed as potentially realistic models of intestinal infection. Quantitation of adhesion to the cells showed isolate 3 82/91 (from a bacteraemia) to adhere at significantly greater numbers than any other isolate tested. This isolate produced a PFGE profile which differed from other S. pilosicoli isolates and so would be of interest for further study. Comparison of bacteraemic and other S. pilosicoli isolates suggested that bacteraemic isolates were not more specifically adapted for adhesion to, or invasion of the epithelial cell layer than other S. pilosicoli isolates. Genotypically similar isolates from differing animal origins adhered to the Caco-2 model at similar levels. Generation of a random genomic library of S. pilosicoli and screening with species specific monoclonal antibody has enabled the identification of a gene sequence encoding a protein which showed significant homology with an ancestral form of the enzyme pyruvate oxidoreductase. Immunoscreening with polyclonal serum identified the sequences of two gene clusters and a probable arylsulphatase. One gene cluster represented a ribosomal gene cluster which has a similar molecular arrangement to Borrelia burgdorjeri, Treponema pallidum and Thermatoga maritima. The other gene cluster contained an ABC transporter protein, sorbitol dehydrogenase and phosphomannose isomerase. An ELISA type assay was used to demonstrate that isolates of S. pilosicoli could adhere to components of the extracellular matrix such as collagen (type 1), fibronectin, laminin, and porcine gastric mucin.
Resumo:
This study covers two areas of contribution to the knowledge, firstly it tried to investigate rigourously the relationships of a number of factors believed that they may affect the climate perception, classified into three types to arrive to prove a hypothesis of the important role that qualification and personal factors play in shaping the climate perception, this is in contrast with situational factors. Secondly, the study tries to recluster the items of a wide-range applied scale for the measurement of climate named HAY in order to overcome the cross-cultural differences between the Kuwaiti and the American society, and to achieve a modified dimensions of climate for a civil service organisation in Kuwait. Furthermore, the study attempts to carry out a diagnostic test for the climate of the Ministry of Public Health in Kuwait, aiming to diagnose the perceived characteristics of the MoPH organisation, and suggests a number of areas to be given attention if an improvement is to be introduced. The study used extensively the statistical and the computer facilities to make the analysis more representing the field data, on the other hand this study is characterised by the very highly responsive rate of the main survey which would affect the findings reliability. Three main field studies are included, the first one was to conduct the main questionnaire where the second was to measure the "should be" climate by the experts of MoPH using the DELPHI technique, and the third was to conduct an extensive meeting with the very top management team in MoPH. Results of the first stage were subject to CLUSTER analysis for the reconstruction of the HAY tool, whereas comparative analysis was carried on between the results of the second and third stages on one side, the first from the other.
Resumo:
This thesis was concerned with investigating methods of improving the IOP pulse’s potential as a measure of clinical utility. There were three principal sections to the work. 1. Optimisation of measurement and analysis of the IOP pulse. A literature review, covering the years 1960 – 2002 and other relevant scientific publications, provided a knowledge base on the IOP pulse. Initial studies investigated suitable instrumentation and measurement techniques. Fourier transformation was identified as a promising method of analysing the IOP pulse and this technique was developed. 2. Investigation of ocular and systemic variables that affect IOP pulse measurements In order to recognise clinically important changes in IOP pulse measurement, studies were performed to identify influencing factors. Fourier analysis was tested against traditional parameters in order to assess its ability to detect differences in IOP pulse. In addition, it had been speculated that the waveform components of the IOP pulse contained vascular characteristic analogous to those components found in arterial pulse waves. Validation studies to test this hypothesis were attempted. 3. The nature of the intraocular pressure pulse in health and disease and its relation to systemic cardiovascular variables. Fourier analysis and traditional parameters were applied to the IOP pulse measurements taken on diseased and healthy eyes. Only the derived parameter, pulsatile ocular blood flow (POBF) detected differences in diseased groups. The use of an ocular pressure-volume relationship may have improved the POBF measure’s variance in comparison to the measurement of the pulse’s amplitude or Fourier components. Finally, the importance of the driving force of pulsatile blood flow, the arterial pressure pulse, is highlighted. A method of combining the measurements of pulsatile blood flow and pulsatile blood pressure to create a measure of ocular vascular impedance is described along with its advantages for future studies.
Resumo:
A nonlinear dynamic model of microbial growth is established based on the theories of the diffusion response of thermodynamics and the chemotactic response of biology. Except for the two traditional variables, i.e. the density of bacteria and the concentration of attractant, the pH value, a crucial influencing factor to the microbial growth, is also considered in this model. The pH effect on the microbial growth is taken as a Gaussian function G0e-(f- fc)2/G1, where G0, G1 and fc are constants, f represents the pH value and fc represents the critical pH value that best fits for microbial growth. To study the effects of the reproduction rate of the bacteria and the pH value on the stability of the system, three parameters a, G0 and G1 are studied in detail, where a denotes the reproduction rate of the bacteria, G0 denotes the impacting intensity of the pH value to microbial growth and G1 denotes the bacterial adaptability to the pH value. When the effect of the pH value of the solution which microorganisms live in is ignored in the governing equations of the model, the microbial system is more stable with larger a. When the effect of the bacterial chemotaxis is ignored, the microbial system is more stable with the larger G1 and more unstable with the larger G0 for f0 > fc. However, the stability of the microbial system is almost unaffected by the variation G0 and G1 and it is always stable for f0 < fc under the assumed conditions in this paper. In the whole system model, it is more unstable with larger G1 and more stable with larger G0 for f0 < fc. The system is more stable with larger G1 and more unstable with larger G0 for f0 > fc. However, the system is more unstable with larger a for f0 < fc and the stability of the system is almost unaffected by a for f0 > fc. The results obtained in this study provide a biophysical insight into the understanding of the growth and stability behavior of microorganisms.
Resumo:
This paper presents the results of a multivariate spatial analysis of 38 vowel formant variables in the language of 402 informants from 236 cities from across the contiguous United States, based on the acoustic data from the Atlas of North American English (Labov, Ash & Boberg, 2006). The results of the analysis both confirm and challenge the results of the Atlas. Most notably, while the analysis identifies similar patterns as the Atlas in the West and the Southeast, the analysis finds that the Midwest and the Northeast are distinct dialect regions that are considerably stronger than the traditional Midland and Northern dialect region indentified in the Atlas. The analysis also finds evidence that a western vowel shift is actively shaping the language of the Western United States.
Resumo:
Purpose: In today's competitive scenario, effective supply chain management is increasingly dependent on third-party logistics (3PL) companies' capabilities and performance. The dissemination of information technology (IT) has contributed to change the supply chain role of 3PL companies and IT is considered an important element influencing the performance of modern logistics companies. Therefore, the purpose of this paper is to explore the relationship between IT and 3PLs' performance, assuming that logistics capabilities play a mediating role in this relationship. Design/methodology/approach: Empirical evidence based on a questionnaire survey conducted on a sample of logistics service companies operating in the Italian market was used to test a conceptual resource-based view (RBV) framework linking IT adoption, logistics capabilities and firm performance. Factor analysis and ordinary least square (OLS) regression analysis have been used to test hypotheses. The focus of the paper is multidisciplinary in nature; management of information systems, strategy, logistics and supply chain management approaches have been combined in the analysis. Findings: The results indicate strong relationships among data gathering technologies, transactional capabilities and firm performance, in terms of both efficiency and effectiveness. Moreover, a positive correlation between enterprise information technologies and 3PL financial performance has been found. Originality/value: The paper successfully uses the concept of logistics capabilities as mediating factor between IT adoption and firm performance. Objective measures have been proposed for IT adoption and logistics capabilities. Direct and indirect relationships among variables have been successfully tested. © Emerald Group Publishing Limited.
Resumo:
Purpose: To assess the validity and repeatability of objective compared to subjective contact lens fit analysis. Methods: Thirty-five subjects (aged 22.0. ±. 3.0 years) wore two different soft contact lens designs. Four lens fit variables: centration, horizontal lag, post-blink movement in up-gaze and push-up recovery speed were assessed subjectively (four observers) and objectively from slit-lamp biomicroscopy captured images and video. The analysis was repeated a week later. Results: The average of the four experienced observers was compared to objective measures, but centration, movement on blink, lag and push-up recovery speed all varied significantly between them (p <. 0.001). Horizontal lens centration was on average close to central as assessed both objectively and subjectively (p > 0.05). The 95% confidence interval of subjective repeatability was better than objective assessment (±0.128. mm versus ±0.168. mm, p = 0.417), but utilised only 78% of the objective range. Vertical centration assessed objectively showed a slight inferior decentration (0.371. ±. 0.381. mm) with good inter- and intrasession repeatability (p > 0.05). Movement-on-blink was lower estimated subjectively than measured objectively (0.269. ±. 0.179. mm versus 0.352. ±. 0.355. mm; p = 0.035), but had better repeatability (±0.124. mm versus ±0.314. mm 95% confidence interval) unless correcting for the smaller range (47%). Horizontal lag was lower estimated subjectively (0.562. ±. 0.259. mm) than measured objectively (0.708. ±. 0.374. mm, p <. 0.001), had poorer repeatability (±0.132. mm versus ±0.089. mm 95% confidence interval) and had a smaller range (63%). Subjective categorisation of push-up speed of recovery showed reasonable differentiation relative to objective measurement (p <. 0.001). Conclusions: The objective image analysis allows an accurate, reliable and repeatable assessment of soft contact lens fit characteristics, being a useful tool for research and optimisation of lens fit in clinical practice.