17 resultados para Cataract - Surgery
Resumo:
Purpose: To examine visual outcomes following bilateral implantation of the FineVision trifocal intraocular lens (IOL; PhysIOL, Liège, Belgium). Methods: 26 patients undergoing routine cataract surgery were implanted bilaterally with the FineVision Trifocal IOL and followed up post-operatively for 3 months. The FineVision optic features a combination of 2 diffractive structures, resulting in distance, intermediate (+1.75 D add) and near vision (+3.50 D add) zones. Apodization of the optic surface increases far vision dominance with pupil aperture. Data collected at the 3 month visit included uncorrected and corrected distance (CDVA) and near vision; subjective refraction; defocus curve testing (photopic and mesopic); contrast sensitivity (CSV-1000); halometry glare testing and a questionnaire (NAVQ) to gauge near vision function and patient satisfaction. Results: The cohort comprised 15 males and 11 females, aged 52.5–82.4 years (mean 70.6 ± 8.2 years). Mean post-operative UDVA was 0.22 ± 0.14 logMAR, with a mean spherical equivalent refraction of +0.02 ± 0.35 D. Mean CDVA was 0.13 ± 0.10 logMAR monocularly, and 0.09 ± 0.07 logMAR binocularly. Defocus curve testing showed an extensive range of clear vision in both photopic and mesopic conditions. Patients showed high levels of satisfaction with their near vision (mean ± 0.9 ± 0.6, where 0 = completely satisfied, and 4 = completely unsatisfied) and demonstrated good spectacle independence. Conclusion: The FineVision IOL can be considered in patients seeking spectacle dependence following cataract surgery, and provide good patient satisfaction with uncorrected vision.
Resumo:
Purpose: To ascertain the agreement level between intra-operative refraction using a prototype surgical Hartmann-Shack aberrometer and subjective refraction a month later. Methods: Fifty-four consecutive patients had their pseudophakic refractive measured with the aberrometer intra-operatively at the end of their cataract surgery. A masked optometrist performed subjective refraction 4 weeks later. The two sets of data were then analysed for correlation. Results: The mean spherical equivalent was −0.14 ± 0.37 D (Range: −1.41 to +1.72 D) with the prototype aberrometer and −0.34 ± 0.32 (−1.64 to +1.88 D) with subjective refraction. The measurements positively correlated to a very high degree (r =+0.81, p < 0.01). In 84.3% of cases the two measurements were within 0.50D of each other. Conclusion: The aberrometer can verify the aimed refractive status of the eye intraoperatively to avoid a refractive surprise. The aberrometer is a useful tool for real time assessment of the ocular refractive status.