56 resultados para Bartlett
Resumo:
Purpose: To determine the feasibility of taking intra-ocular pressure (IOP) readings with Goldmann-type applanation tonometer probe covered with cling film to avoid transmission of Creutzfeldt-Jakob disease (CJD). Methods: Data were collected on two occasions from the right eyes of 30 healthy subjects using a Perkins applanation tonometer. On each occasion, a single tonometry measurement was made with and without cling film covering. Results: Cling film covering brought about a statistically significant IOP bias (-0.8 mmHg on first occasion and -1.17 mmHg on second occasion). The 95% limits of agreement, between readings made with and without cling film covering, were ±3.4 mmHg on first occasion; ±2.5 mmHg on second occasion. A statistically significant reduction of inter-sessional repeatability was observed for readings taken with cling film (±5.2 mmHg) compared to those made without (±3.9 mmHg). Conclusions: Even if the above findings are found to be acceptable, given the known intra-subject variations of this type of tonometry (±4 mmHg), ethical and legal considerations relating to the barrier properties of cling film are likely to prevent its routine use by optometrists. © 2004 The College of Optometrists.
Resumo:
The role of nutritional supplementation is of increasing interest with regard to ocular disease. Randomised controlled trials have demonstrated the effectiveness of supplementation for age-related macular degeneration, and formulations are now being developed for use by people with diabetes and diabetic retinopathy. The aim of this review was to synthesise the evidence for use of nutritional supplementation in type 2 diabetes. MEDLINE and EMBASE databases were searched using a systematic approach. Only double-masked randomised controlled trials were selected. A total of 50 trials were identified as suitable for inclusion. The potential role of alpha-lipoic acid, chromium, folic acid, isoflavones, magnesium, Pycnogenol®, selenium, vitamin C, vitamin E, and zinc in the treatment of type 2 diabetes is discussed. The review of trials identifies positive effects of these nutrients on various outcome measures relating to insulin resistance and cardiovascular factors. Chromium was the most studied supplement, accounting for 16 of the 50 trials. A majority of the trials found a positive effect of chromium on fasting plasma glucose. Isoflavones were found to have a positive effect on insulin resistance and cardiovascular outcome measures, but only when combined with soy proteins. Vitamin E is reported to reduce oxidative stress at levels of 200 mg day-1 or more.
Resumo:
Background & aims It has been suggested that retinal lutein may improve visual acuity for images that are illuminated by white light. Our aim was to determine the effect of a lutein and antioxidant dietary supplement on visual function. Methods A prospective, 9- and 18-month, double-masked randomised controlled trial. For the 9-month trial, 46 healthy participants were randomised (using a random number generator) to placebo (n=25) or active (n=21) groups. Twenty-nine of these subjects went on to complete 18 months of supplementation, 15 from the placebo group, and 14 from the active group. The active group supplemented daily with 6mg lutein combined with vitamins and minerals. Outcome measures were distance and near visual acuity, contrast sensitivity, and photostress recovery time. The study had 80% power at the 5% significance level for each outcome measure. Data were collected at baseline, 9, and 18 months. Results There were no statistically significant differences between groups for any of the outcome measures over 9 or 18 months. Conclusion There was no evidence of effect of 9 or 18 months of daily supplementation with a lutein-based nutritional supplement on visual function in this group of people with healthy eyes. ISRCTN78467674.
Resumo:
Objective: The aim of the study is to determine the effect of lutein combined with vitamin and mineral supplementation on contrast sensitivity in people with age-related macular disease (ARMD). Design: A prospective, 9-month, double-masked randomized controlled trial. Setting: Aston University, Birmingham, UK and a UK optometric clinical practice. Subjects: Age-related maculopathy (ARM) and atrophic age-related macular degeneration (AMD) participants were randomized (using a random number generator) to either placebo (n = 10) or active (n=15) groups. Three of the placebo group and two of the active group dropped out. Interventions: The active group supplemented daily with 6 mg lutein combined with vitamins and minerals. The outcome measure was contrast sensitivity (CS) measured using the Pelli-Robson chart, for which the study had 80% power at the 5% significance level to detect a change of 0.3log units. Results: The CS score increased by 0.07 ± 0.07 and decreased by 0.02 ± 0.18 log units for the placebo and active groups, respectively. The difference between these values is not statistically significant (z = 0.903, P = 0.376). Conclusion: The results suggest that 6 mg of lutein supplementation in combination with other antioxidants is not beneficial for this group. Further work is required to establish optimum dosage levels.
Resumo:
The purpose of this study was to determine if there was an objective difference in reading between four commonly available lamps, of varying spectral radiance, for 13 subjects with age-related maculopathy (ARM) or non-exudative age-related macular degeneration (AMD) - logMAR visual acuity between 0.04 and 0.68. At a constant illuminance of 2000 lux, there was no interaction between ARM and AMD subgroups and no statistically significant difference between the lamps: standard (clear envelope) incandescent, daylight simulation (blue tint envelope) incandescent, compact fluorescent and halogen incandescent, for any reading outcome measure (threshold print size p = 0.67, critical print size p = 0.74, acuity reserve p = 0.84 and mean reading rate p = 0.78). For lamps typically used in low-vision rehabilitation, a clinically significant effect of spectral radiance on reading for people with ARM or non-exudative AMD is unlikely. © 2007 The College of Optometrists.
Resumo:
The role of oxidation in the development of age-related eye disease has prompted interest in the use of nutritional supplementation for prevention of onset and progression. Our aim is to highlight possible contraindications and adverse reactions of isolated or high dose ocular nutritional supplements. Web of Science and PubMed database searches were carried out, followed by a manual search of the bibliographies of retrieved articles. Vitamin A should be avoided in women who may become pregnant, in those with liver disease, and in people who drink heavily. Relationships have been found between vitamin A and reduced bone mineral density, and beta-carotene and increased risk of lung cancer in smoking males. Vitamin E and Ginkgo biloba have anticoagulant and anti-platelet effects respectively, and high doses are contraindicated in those being treated for vascular disorders. Those patients with contraindications or who are considered at risk of adverse reactions should be advised to seek specialist dietary advice via their medical practitioner. © 2005 The College of Optometrists.
Resumo:
The role of nutritional supplementation in prevention of onset or progression of ocular disease is of interest to health care professionals and patients. The aim of this review is to identify those antioxidants most appropriate for inclusion in an ideal ocular nutritional supplement, suitable for those with a family history of glaucoma, cataract, or age-related macular disease, or lifestyle factors predisposing onset of these conditions, such as smoking, poor nutritional status, or high levels of sunlight exposure. It would also be suitable for those with early stages of age-related ocular disease. Literature searches were carried out on Web of Science and PubMed for articles relating to the use of nutrients in ocular disease. Those highlighted for possible inclusion were vitamins A, B, C and E, carotenoids beta-carotene, lutein, and zeaxanthin, minerals selenium and zinc, and the herb, Ginkgo biloba. Conflicting evidence is presented for vitamins A and E in prevention of ocular disease; these vitamins have roles in the production of rhodopsin and prevention of lipid peroxidation respectively. B vitamins have been linked with a reduced risk of cataract and studies have provided evidence supporting a protective role of vitamin C in cataract prevention. Beta-carotene is active in the prevention of free radical formation, but has been linked with an increased risk of lung cancer in smokers. Improvements in visual function in patients with age-related macular disease have been noted with lutein and zeaxanthin supplementation. Selenium has been linked with a reduced risk of cataract and activates the antioxidant enzyme glutathione peroxidase, protecting cell membranes from oxidative damage while zinc, although an essential component of antioxidant enzymes, has been highlighted for risk of adverse effects. As well as reducing platelet aggregation and increasing vasodilation, Gingko biloba has been linked with improvements in pre-existing field damage in some patients with normal tension glaucoma. We advocate that vitamins C and E, and lutein/zeaxanthin should be included in our theoretically ideal ocular nutritional supplement.
Resumo:
This review compares the results of studies that have investigated the impact of lutein and zeaxanthin supplementation on macular pigment optical density (MPOD) with those that have investigated the reliability of techniques used to measure macular pigment optical density. The review will focus on studies that have used heterochromatic flicker photometry for measurement of macular pigment optical density, as this is the only technique that is currently available commercially to clinicians. We identified articles that reported on supplementation with lutein and/or zeaxanthin and/or meso-zeaxanthin on macular pigment optical density measurement techniques published in peer-reviewed journals, through a multi-staged, systematic approach. Twenty-four studies have investigated the repeatability of MPOD measurements using heterochromatic flicker photometry. Of these, 10 studies provided a coefficient of repeatability or data from which the coefficient could be calculated, with a range in values of 0.06 to 0.58. The lowest coefficient of repeatability assessed on naïve subjects alone was 0.08. These values tell us that, at best, changes greater than 0.08 can be considered clinically significant and at worst, only changes greater than 0.58 can be considered clinically significant. Six studies assessed the effect of supplementation with up to 20 mg/day lutein on macular pigment optical density measured using heterochromatic flicker photometry and the mean increase in macular pigment optical density ranged from 0.025 to 0.09. It seems reasonable to conclude that the chance of eliciting an increase in macular pigment optical density during six months of daily supplementation with between 10 and 20 mg lutein that is of sufficient magnitude to be detected by using heterochromatic flicker photometry on an individual basis is small. Commercially available heterochromatic flicker photometers for macular pigment optical density assessment in the clinical environment appear to demonstrate particularly poor coefficient of repeatability values. Clinicians should exercise caution when considering the purchase of these instruments for potential monitoring of macular pigment optical density in response to supplementation in individual patients.
Resumo:
Purpose. To assess the relationship between macular pigment optical density (MPOD) and blood markers for antioxidant defense in otherwise healthy volunteers. Methods. Forty-seven healthy volunteers were subjected to blood analysis to detect the level of circulating glutathione in its reduced (GSH) and oxidized (GSSG) forms. The level of MPOD was measured using heterochromatic flicker photometry. Systemic blood pressure (BP) parameters, heart rate (HR), body mass index (BMI), and plasma levels of total, HDL, and LDL cholesterol and triglycerides (TGs) were also determined. Results. A simple correlation model revealed that the level of MPOD correlated significantly and positively with both GSH (P < 0.001) and t-GSH (P < 0.001) levels but not with those of GSSG (P > 0.05). Age, sex, systemic BP parameters, HR, BMI, and plasma levels of cholesterol and TGs did not have any influence on either MPOD or glutathione levels (all P > 0.05). In addition, a forward stepwise multiple regression analysis showed MPOD to have a significantly and independent correlation with GSH levels (ß = 0.63; P < 0.001). Conclusions. In otherwise healthy older individuals, there is a positive correlation between local and systemic antioxidant defense mechanisms.
Resumo:
Background/aims. The MacuScope uses a psychophysical technique called heterochromic flicker photometry to measure macular pigment optical density (MPOD). Our aim was to determine the measurement variability (noise) of the MacuScope. Methods. Thirty-eight normally sighted participants who ranged in age from 19 to 46 years (25.7±7.6 years) were recruited from staff and students of Aston University. Data were collected by two operators, HB and JA, in two sessions separated by 1 week in order to assess test repeatability and reproducibility. Results. The overall mean MPOD for the cohort was 0.47±0.14. There was a significant negative correlation between MacuScope MPOD readings and age (r=-0.368, p=0.023). Coefficients were 0.45 and 0.58 for repeatability, and 0.49 and 0.36 for reproducibility. For each pair of results, there was a significant positive correlation between mean and difference MPOD values. Conclusions. If MPOD is being monitored over time then any change less than 0.58 units should not be considered clinically significant as it is very likely to be due to instrument noise. The size of the coefficient appears to be positively correlated with MPOD.
Resumo:
Background: Age-related macular degeneration (ARMD) is the leading cause of visual disability in people over 60 years of age in the developed world. The success of treatment deteriorates with increased latency of diagnosis. The purpose of this study was to determine the reliability of the macular mapping test (MMT), and to investigate its potential as a screening tool. Methods: The study population comprised of 31 healthy eyes of 31 participants. To assess reliability, four macular mapping test (MMT) measurements were taken in two sessions separated by one hour by two practitioners, with reversal of order in the second session. MMT readings were also taken from 17 age-related maculopathy (ARM), and 12 AMD affected eyes. Results: For the normal cohort, average MMT scores ranged from 85.5 to 100.0 MMT points. Scores ranged from 79.0 to 99.0 for the ARM group and from 9.0 to 92.0 for the AMD group. MMT scores were reliable to within ± 7.0 points. The difference between AMD affected eyes and controls (z = 3.761, p = < 0.001) was significant. The difference between ARM affected eyes and controls was not significant (z = -0.216, p = 0.829). Conclusion: The reliability data shows that a change of 14 points or more is required to indicate a clinically significant change. This value is required for use of the MMT as an outcome measure in clinical trials. Although there was no difference between MMT scores from ARM affected eyes and controls, the MMT has the advantage over the Amsler grid in that it uses a letter target, has a peripheral fixation aid, and it provides a numerical score. This score could be beneficial in office and home monitoring of AMD progression, as well as an outcome measure in clinical research. © 2005 Bartlett et al; licensee BioMed Central Ltd.
Resumo:
BACKGROUND: Some studies report that increased tear osmolarity is a reliable indicator of dry eye syndrome (DES). The OcuSense TearLab™ osmometer requires less than a 100-nl sample of tears and provides an instant quantitative result. Our aim was to clinically evaluate this instrument in terms of its reproducibility and repeatability. METHODS: Twenty-nine participants who ranged in age from 19 to 49 years (mean?±?SD: 23.3?±?5.5 years) were recruited. Osmolarity readings were collected by two operators, in two sessions separated by 1 or 2 weeks in order to assess test reproducibility and repeatability. RESULTS: The coefficient of reproducibility was 39 mOsms/l; the coefficient of repeatability was 33 mOsms/l. CONCLUSIONS: Our mean coefficient of variation over four readings for 29 subjects is 2.9%, which compares well with that reported by the manufacturer. Our results inform practitioners about the level of change over time that can be considered clinically relevant for healthy subjects. This value is 33mOsms/l; any change smaller than this could be attributed to measurement noise.
Resumo:
As a research group with no commercial interest in any macular pigment optical density (MPOD) measurement devices or nutritional supplements, we feel that we were well-placed to carry out an independent clinical assessment of the reliability of the MPS 9000 (Tinsley Precision Instruments, Redhill, Surrey, UK). Our study was prompted by the fact that we could not find any reported coefficient of repeatability value within the literature, and none was provided by the manufacturer.1 We had planned to use this instrument in our own research studies investigating the impact of nutritional supplementation on MPOD. For this purpose, we needed …
Resumo:
The aim of this research was to determine the effect of a lutein-based nutritional supplemented on measures of visual function in normal and ARMD-affected eyes. Thirty participants were recruited to the ARMD cohort (aged between 55 and 82 years, mean ± SD: 69.2 ± 7.8) and 46 were recruited into the normal cohort (aged between 22 and 73 years, mean ± SD: 50.0 ± 15.9). Outcome measures were distance (DVA) and near (NVA) visual acuity, contrast sensitivity (CS), photostress recovery time measured with the Eger Macular Stressometer (EMS), central visual function assessed with the Macular Mapping test (MMT), and fundus photography. Reliability studies were carried out for the EMS and the MMT. A change of 14 s is required to indicate a clinically significant change in EMS time, and a change of 14 MMT points is required to indicate a clinically significant change in MMT score. Sample sizes were sufficient for the trial to have 80% power to detect a significant clinical effect at the 5% significance level for all outcome measures in the normal cohort, and for CS in the ARMD cohort. The study demonstrated that a nutritional supplement containing 6mg lutein, 750 mg vitamin A, 250 mg vitamin C, 34 mg vitamin E, 10 mg zinc, and 0.5 mg copper had no effect on the outcome measures over nine or 18 months in normal or ARMD affected participants. The finding that nine months of antioxidant supplementation, in this case, has no significant effect on CS in ARMD-affected participants adds to the literature, and contrasts with previous RCTs, the AREDS and the LAST. This project has added to the debate about the use of nutritional supplementation prior to the onset of ARMD.
Resumo:
Macular pigment has been the focus of much attention in recent years, as a potential modifiable risk factor for age-related macular degeneration. This interest has been heightened by the ability to measure macular pigment optical density (MPOD) in vivo.