26 resultados para Advent.
Resumo:
The advent of the harmonic neutralised shunt Converter Compensator as a practical means of reactive power compensation in power transmission systems has cleared ground for wider application of this type of equipment. An experimental 24-pulse voltage sourced convector has been successfully applied in controlling the terminal power factor of a 1.5kW, 240V three phase cage rotor induction motor, whose winding has been used in place of the usual phase shifting transformers. To achieve this, modifications have been made to the conventional stator winding of the induction machine. These include an unconventional phase spread and facilitation of compensator connections to selected tapping points between stator coils to give a three phase winding with a twelve phase connection to the twenty four pulse converter. Theoretical and experimental assessments of the impact of these modifications and attachment of the compensator have shown that there is a slight reduction in the torque developed at a given slip and in the combined system efficiency. There is also an increase in the noise level, also a consequence of the harmonics. The stator leakage inductance gave inadequate coupling reactance between the converter and the effective voltage source, necessitating the use of external inductors in each of the twelve phases. The terminal power factor is fully controllable when the induction machine is used either as a motor or as a generator.
Resumo:
There is a great deal of literature about the initial stages of innovative design. This is the process whereby a completely new product is conceived, invented and developed. In industry, however, the continuing success of a company is more often achieved by improving or developing existing designs to maintain their marketability. Unfortunately, this process of design by evolution is less well documented. This thesis reports the way in which this process was improved for the sponsoring company. The improvements were achieved by implementing a new form of computer aided design (C.A.D.) system. The advent of this system enabled the company to both shorten the design and development time and also to review the principles underlying the existing design procedures. C.A.D. was a new venture for the company and care had to be taken to ensure that the new procedures were compatible with the existing design office environment. In particular, they had to be acceptable to the design office staff. The C.A.D. system produced guides the designer from the draft specification to the first prototype layout. The computer presents the consequences of the designer's decisions clearly and fully, often by producing charts and sketches. The C.A.D. system and the necessary peripheral facilities were implemented, monitored and maintained. The system structure was left sufficiently flexible for maintenance to be undertaken quickly and effectively. The problems encountered during implementation are well documented in this thesis.
Resumo:
Over the years several articles have tracked the impact of technology on various aspects of the sales domain. However, the advent of social media and technologies related to social media has gone largely unnoticed in the literature. This article first provides brief attention to changing aspects of technology within the sales environment, leading to the identification of social media as a dominant new selling tool. A qualitative approach (focus groups) is employed to explore the breadth of current technology usage by sales managers and salespeople. Analysis of the data, collected in the United States and the United Kingdom, reveals six major themes: connectivity, relationships, selling tools, generational, global, and sales/marketing interface. Results provide evidence of a revolution in the buyer-seller relationship that includes some unanticipated consequences both for sales organization performance and needed future research contributions.
Resumo:
Pharmacy originates from a background of medication compounding and supply. More recently, this role has developed away from an absolute focus on the supply of pharmaceuticals with, for example, the advent of pharmacist prescribing. Nevertheless, for a majority of the profession, medication supply remains a core activity. Regulation of the pharmacy profession is now the responsibility of the General Pharmaceutical Council, although up until 27 September 2010, this role fell to the Royal Pharmaceutical Society of Great Britain (RPSGB). Before this change, in one of the most high-profile legal cases involving a pharmacist in a professional capacity, R. v Lee, a pharmacist was prosecuted firstly for gross negligence manslaughter, later revised to offences under the Medicines Act 1968, for a single error relating to medication supply, and was given a suspended custodial sentence. Offences against sections 64 or 85 of the Medicines Act are absolute offences and there is no due diligence defence. Prosecution of a pharmacist for the supply of incorrect medication may seem a measured course of action to protect the public from the wrongful supply of potent pharmacotherapeutic agents; however, further analysis of Lee indicates that this approach may be counterproductive. An appeal of the original conviction in the Lee case has resulted in a clarification of the interpretation of section 85(5); however currently, prosecutions under section 64 are still a possibility. Owing to the seriousness of a criminal conviction under section 64, this continuation will potentially stifle the profession's ability to learn from dispensing errors. © The Author [2013]. Published by Oxford University Press; all rights reserved.
Resumo:
What is meant by the term ‘specialist contact lens fitting’? Or put another way, what would be considered non-specialist contact lens fitting? Is there such a thing as routine contact lens fitting? Soft or silicone hydrogel fitting for daily wear would probably be considered as routine contact lens fitting, but would extended or flexible wear remain in the same category or would they be considered a specialist fit? Different eras will classify different products as being ‘specialist’. Certainly twenty years ago soft toric contact lenses were considered as being speciality lenses but today would be thought of as routine lenses. Conversely, gas permeable lenses were thought of as mainstream twenty years ago but now are considered as speciality lenses. Although this would not be the same globally, as in some countries (such as Netherlands, France and Japan) gas permeable lens fitting remains popular and is not on the decline as in other countries (Canada, Australia and Sweden) [1]. Bandage soft lenses applied after surface laser refractive procedures would be considered as therapeutic lenses but in reality they are just plano thin hydrogel lenses worn constantly for 3–4 days to allow the underlying epithelium to convalesce and are then removed [2]. Some patients find that wearing hydrogel lenses during periods when they suffer from seasonal allergies actually improves their ocular comfort as the contact lens acts as a barrier to the allergen [3] and [4]. Scleral lenses have long been considered speciality lenses, apart from a time when they were the only lenses available but at that time all contact lens work would have been considered speciality practice! Nowadays we see the advent of mini-scleral designs and we see large diameter gas permeable lenses too. It is possible that these lenses increase the popularity of gas permeable lenses again and they become more main stream. So it would seem that the lines between routine and speciality contact lens fitting are not clear. Whether a lens is classed a specialist fit or not would depend on the lens type, why it was fitted, where in the world the fitting was being done and even the era in which it was fitted. This begs the question as to what would be considered entry level knowledge in contact lens fitting. This may not be an issue for most BCLA members or CLAE readers but certainly would be for bodies such as the College of Optometrists (UK) or the Association of British Dispensing Opticians when they are planning the final registration examinations for budding practitioners or when planning the level of higher level qualifications such as College Certificates or Diplomas. Similarly for training institutions when they are planning their course content. This becomes even trickier when trying to devise a qualification that spans across many countries, like the European Diploma in Optometry and Optics. How do we know if the training and examination level is correct? One way would be to analyse things when they go wrong and if patterns of malpractice are seen then maybe that could be used as an indicator to more training being needed. There were 162 Fitness to Practice Hearing at the General Optical Council between 2001 and 2010. Forty-seven of these were clinically related case, 39 fraud related, and 76 others. Of the clinical ones only 3 were contact lens related. So it would appear that as whole, in the profession, contact lens clinical skills are not being questioned too often (although it seems a few of us can’t keep our hands out the cookie jar!).
Resumo:
The advent of the internet has led to the new phenomenon of ‘cyberstalking’. This paper examines the extent of this problem. It is argued that all of the estimates commonly cited are flawed because they rely on inaccurate or outdated information or are based on a number of unproven assumptions. Although some estimates suggest that there may be as many as 10 million victims in the United States and Canada alone, available evidence supports a far smaller estimate. It is concluded that additional research is needed to arrive at more accurate and reliable estimates
Resumo:
The treatment of choroidal neovascularisation (CNV) secondary to pathological myopia has presented a number of problems to ophthalmologists over the years, but the advent of photodynamic therapy (PDT) with verteporfin has changed how we manage these patients. Until PDT became available, the use of laser photocoagulation for extra and juxtafoveal lesions had been shown to be effective in the short term in preventing loss of vision, although the risk of regrowth of CNV and undertreatment were well recognised. However, even in apparent successful cases of photocoagulation, laser scar enlargement and creepage into the fovea in the mid-to-long term often occurred with resulting loss of central vision.1 Other options for treatment were very limited with little evidence that other modalities such as transpupillary thermotherapy or submacular surgery and macular transplantation surgery would be successful in highly myopic eyes. The evidence for the role of PDT and verteporfin CNV secondary to pathological myopia comes from the verteporfin in photodynamic therapy (VIP) study that has shown how effective this treatment is in eyes with subfoveal CNV.2, 3 Now in this publication, Lam et al4 from Hong Kong have shown that PDT is also effective in juxtafoveal CNV, with high myopia. They performed a small prospective study of 11 patients of mean age 44.8 years, with 12 months of follow-up. They found that there was a mean improvement of 1.8 lines of LogMAR best-corrected visual acuity (BCVA) at 12 months, with a mean number of 2.3 PDT treatments. The most rapid improvement occurred within the first 3 months of treatment and by 12 months none of the patients had suffered a deterioration in BCVA from baseline. There were no cases of adverse effects from the infusion or laser treatment. For ophthalmologists dealing with patients with CNV secondary to causes other than AMD, this is further evidence of the effectiveness of PDT with verteporfin in maintaining vision. These patients are likely to be younger than those with AMD and are likely to be in active employment and supporting families, and clearly the preservation of best vision possible is imperative in this group. It is therefore encouraging for ophthalmologists in the United Kingdom that the verteporfin in PDT Cohort Study (VPDT Study) includes the ability to treat patients with subfoveal CNV secondary to high myopia if they fulfill National Institute of Clinical Excellence guidelines, and will allow representations to be made on an individual basis for treatment of juxtafoveal lesions.5 For those ophthalmologists used to juggling increased patient expectations with scarce NHS resources, this is promising news and will allow us to offer a better standard of care to our patients.
Resumo:
With the advent of GPS enabled smartphones, an increasing number of users is actively sharing their location through a variety of applications and services. Along with the continuing growth of Location-Based Social Networks (LBSNs), security experts have increasingly warned the public of the dangers of exposing sensitive information such as personal location data. Most importantly, in addition to the geographical coordinates of the user’s location, LBSNs allow easy access to an additional set of characteristics of that location, such as the venue type or popularity. In this paper, we investigate the role of location semantics in the identification of LBSN users. We simulate a scenario in which the attacker’s goal is to reveal the identity of a set of LBSN users by observing their check-in activity. We then propose to answer the following question: what are the types of venues that a malicious user has to monitor to maximize the probability of success? Conversely, when should a user decide whether to make his/her check-in to a location public or not? We perform our study on more than 1 million check-ins distributed over 17 urban regions of the United States. Our analysis shows that different types of venues display different discriminative power in terms of user identity, with most of the venues in the “Residence” category providing the highest re-identification success across the urban regions. Interestingly, we also find that users with a high entropy of their check-ins distribution are not necessarily the hardest to identify, suggesting that it is the collective behaviour of the users’ population that determines the complexity of the identification task, rather than the individual behaviour.
Resumo:
The advent of global competition has introduced the need for new competitive manufacturing strategies. The implementation of new strategies has a dramatic effect on measuring product cost compared to traditional management accounting methods. It is found that new cost management methods are required to measure success and support decision-making within the new strategies. One example is the consequences of using traditional management accounting methods for measuring the effects of lean having catastrophic results during reporting. Such results steer managers away from lean manufacture based upon a false picture of the potential benefits. This research examines cost management methods potentially applicable within the automotive supplier sector. Because of the lack of cost-related data collected within the supplier sector companies, this paper ends with a demonstration of a novel method for use in data scarce environments. Copyright © 2008 Inderscience Enterprises Ltd.
Resumo:
Full text: We thank Tsilimbaris et al1 for their comments on the appropriateness of the term ‘myopic foveoschisis’ to describe the condition that is characterized by the separation of neural retina layers associated with high myopia and posterior staphyloma. They have proposed the term ‘myopic ectatic retinopathy’ as a more literal and functionally more accurate descriptor of the condition to avoid the use of the word ‘schisis’, which may be misleading because it is also used to describe other conditions where there is separation of neural retina layers without the presence of staphyloma.2 Using the word ‘ectatic’ for this condition would imply that we are fairly certain about the pathogenesis and mechanistic factors that underlie its development and progression. However, this is not the case, unfortunately, as our review of the literature has shown. There are several theories ranging from vitreous traction to sclerosing changes of retinal vessels to progression of staphylomas as possible etiological factors. Therefore, it is likely to be multifactorial in nature—hence the success reported with different procedures that address either the vitreous traction factor using vitrectomy, peel plus tamponade or the scleral ectasia factor using posterior buckling techniques. In the absence of a good understanding of underlying pathogenesis, it is probably best to use purely descriptive names rather than mechanistic terms. The use of descriptive terms, even though similar, do not necessarily cause confusion as long as they are widely accepted as differentiating terminology, for example, postoperative pseudophakic cystoid macular edema (Irvine–Gass syndrome) vs cystoid macular edema associated with posterior uveitis in a phakic patient. The introduction of too many mechanistic or pathogenetic terms in the absence of clear understating of etiology can in fact cause more confusion, for example, serous chorioretinopathy vs central serous retinopathy vs serous choroidopathy. The confinement to broad descriptive terms can enhance communication and reduce confusion without committing to any presumption about etiology until it is better understood. This approach is probably best illustrated by the recent advances in the understanding of mactel21, a condition initially described and classified, using descriptive nomenclature, by Don Gass as bilateral, idiopathic acquired juxtafoveolar telangiectasis (Group2A) and as distinctly different from unilateral, congenital parafoveolar telangiectasis (Group 1A; Gass,3 pp 504–506 vs 127–128). Finally, it is worthy to note that for myopic foveoschisis associated with a staphyloma that is associated with outer layer macular detachment, Don Gass also descriptively included the additional observation (before the advent of OCT) that the retinal profile was concave rather than convex in shape, thereby differentiating it from rhegmatogenous detachments with recruitment of subretinal fluid that is associated with posteriorly located breaks and macular holes in myopic eyes. References 1.Tsilimbaris MK, Vavvas DG, Bechrakis NE. Myopic foveoschisis: an ectatic retinopathy, not aschisis. Eye 2016; 30: 328–329. 2.Powner MB, Gillies MC, Tretiach M, Scott A, Guymer RH, Hageman GS et al. Perifoveal müller cell depletion in a case of macular telangiectasia type 2. Ophthalmology 2010; 117(12): 2407–2416. 3.Gass DM. Stereoscopic Atlas of Macular Diseases: Diagnosis and Treatment, 4th edn. Mosby-Yearbook: St. Louis, 1997.
Resumo:
The year so far has been a slow start for many businesses, but at least we have not seen the collapse of as many businesses that we were seeing around two years ago. We are, however, still well and truly in the midst of a global recession. Interest rates are still at an all time low, UK house prices seem to be showing little signs of increase (except in London where everyone still seems to want to live!) and for the ardent shopper there are bargains to be had everywhere. It seems strange that prices on the high street do not seem to have increased in over ten years. Mobile phones, DVD players even furniture seems to be cheaper than they used to be. Whist much of this is down to cheaper manufacturing and the rest could probably be explained by competition within the market place. Does this mean that quality suffered too? Now that we live in a world when if a television is not working it is thrown away and replaced. There was a time when you would take it to some odd looking man that your father would know who could fix it for you. (I remember our local television fix-it man, with his thick rimmed bifocal spectacles and a poor comb-over; he had cardboard boxes full of resistors and electrical wires on the floor of his front room that smelt of soldering irons!) Is this consumerism at an extreme or has this move to disposability made us a better society? Before you think these are just ramblings there is a point to this. According to latest global figures of contact lens sales the vast majority of contact lenses fitted around the world are daily, fortnightly or monthly disposable hydrogel lenses. Certainly in the UK over 90% of lenses are disposable (with daily disposables being the most popular, having a market share of over 50%). This begs the question – is this a good thing? Maybe more importantly, do our patients benefit? I think it is worth reminding ourselves why we went down the disposability route with contact lenses in the first place, and unlike electrical goods it was not just so we did not have to take them for repair! There are the obvious advantages of overcoming problems of breakage and tearing of lenses and the lens deterioration with age. The lenses are less likely to be contaminated and the disinfection is either easier or not required at all (in the case of daily disposable lenses). Probably the landmark paper in the field was the work more commonly known as the ‘Gothenburg Study’. The paper, entitled ‘Strategies for minimizing the Ocular Effects of Extended Contact Lens Wear’ published in the American Journal of Optometry in 1987 (volume 64, pages 781-789) by Holden, B.A., Swarbrick, H.A., Sweeney, D.F., Ho, A., Efron, N., Vannas, A., Nilsson, K.T. They suggested that contact lens induced ocular effects were minimised by: •More frequently removed contact lenses •More regularly replaced contact lenses •A lens that was more mobile on the eye (to allow better removal of debris) •Better flow of oxygen through the lens All of these issues seem to be solved with disposability, except the oxygen issue which has been solved with the advent of silicone hydrogel materials. Newer issues have arisen and most can be solved in practice by the eye care practitioner. The emphasis now seems to be on making lenses more comfortable. The problems of contact lens related dry eyes symptoms seem to be ever present and maybe this would explain why in the UK we have a pretty constant contact lens wearing population of just over three million but every year we have over a million dropouts! That means we must be attracting a million new wearers every year (well done to the marketing departments!) but we are also losing a million wearers every year. We certainly are not losing them all to the refractive surgery clinics. We know that almost anyone can now wear a contact lens and we know that some lenses will solve problems of sharper vision, some will aid comfort, and some will be useful for patients with dry eyes. So if we still have so many dropouts then we must be doing something wrong! I think the take home message has to be ‘must try harder’! I must end with an apology for two errors in my editorial of issue 1 earlier this year. Firstly there was a typo in the first sentence; I meant to state that it was 40 years not 30 years since the first commercial soft lens was available in the UK. The second error was one that I was unaware of until colleagues Geoff Wilson (Birmingham, UK) and Tim Bowden (London, UK) wrote to me to explain that soft lenses were actually available in the UK before 1971 (please see their ‘Letters to the Editor’ in this issue). I am grateful to both of them for correcting the mistake.