18 resultados para Acoustic ground discrimination system (ADGS) ECHOplus
Resumo:
Objective: The aim of this study was to design a novel experimental approach to investigate the morphological characteristics of auditory cortical responses elicited by rapidly changing synthesized speech sounds. Methods: Six sound-evoked magnetoencephalographic (MEG) responses were measured to a synthesized train of speech sounds using the vowels /e/ and /u/ in 17 normal hearing young adults. Responses were measured to: (i) the onset of the speech train, (ii) an F0 increment; (iii) an F0 decrement; (iv) an F2 decrement; (v) an F2 increment; and (vi) the offset of the speech train using short (jittered around 135. ms) and long (1500. ms) stimulus onset asynchronies (SOAs). The least squares (LS) deconvolution technique was used to disentangle the overlapping MEG responses in the short SOA condition only. Results: Comparison between the morphology of the recovered cortical responses in the short and long SOAs conditions showed high similarity, suggesting that the LS deconvolution technique was successful in disentangling the MEG waveforms. Waveform latencies and amplitudes were different for the two SOAs conditions and were influenced by the spectro-temporal properties of the sound sequence. The magnetic acoustic change complex (mACC) for the short SOA condition showed significantly lower amplitudes and shorter latencies compared to the long SOA condition. The F0 transition showed a larger reduction in amplitude from long to short SOA compared to the F2 transition. Lateralization of the cortical responses were observed under some stimulus conditions and appeared to be associated with the spectro-temporal properties of the acoustic stimulus. Conclusions: The LS deconvolution technique provides a new tool to study the properties of the auditory cortical response to rapidly changing sound stimuli. The presence of the cortical auditory evoked responses for rapid transition of synthesized speech stimuli suggests that the temporal code is preserved at the level of the auditory cortex. Further, the reduced amplitudes and shorter latencies might reflect intrinsic properties of the cortical neurons to rapidly presented sounds. Significance: This is the first demonstration of the separation of overlapping cortical responses to rapidly changing speech sounds and offers a potential new biomarker of discrimination of rapid transition of sound.
Resumo:
A new approach is described herein, where neutron reflectivity measurements that probe changes in the density profile of thin films as they absorb material from the gas phase have been combined with a Love wave based gravimetric assay that measures the mass of absorbed material. This combination of techniques not only determines the spatial distribution of absorbed molecules, but also reveals the amount of void space within the thin film (a quantity that can be difficult to assess using neutron reflectivity measurements alone). The uptake of organic solvent vapours into spun cast films of polystyrene has been used as a model system with a view to this method having the potential for extension to the study of other systems. These could include, for example, humidity sensors, hydrogel swelling, biomolecule adsorption or transformations of electroactive and chemically reactive thin films. This is the first ever demonstration of combined neutron reflectivity and Love wave-based gravimetry and the experimental caveats, limitations and scope of the method are explored and discussed in detail.
Resumo:
Our goal here is a more complete understanding of how information about luminance contrast is encoded and used by the binocular visual system. In two-interval forced-choice experiments we assessed observers' ability to discriminate changes in contrast that could be an increase or decrease of contrast in one or both eyes, or an increase in one eye coupled with a decrease in the other (termed IncDec). The base or pedestal contrasts were either in-phase or out-of-phase in the two eyes. The opposed changes in the IncDec condition did not cancel each other out, implying that along with binocular summation, information is also available from mechanisms that do not sum the two eyes' inputs. These might be monocular mechanisms. With a binocular pedestal, monocular increments of contrast were much easier to see than monocular decrements. These findings suggest that there are separate binocular (B) and monocular (L,R) channels, but only the largest of the three responses, max(L,B,R), is available to perception and decision. Results from contrast discrimination and contrast matching tasks were described very accurately by this model. Stimuli, data, and model responses can all be visualized in a common binocular contrast space, allowing a more direct comparison between models and data. Some results with out-of-phase pedestals were not accounted for by the max model of contrast coding, but were well explained by an extended model in which gratings of opposite polarity create the sensation of lustre. Observers can discriminate changes in lustre alongside changes in contrast.