29 resultados para Accuracy.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The studies presented in this thesis were carried out because of a lack of previous research with respect to (a) the habits and attitudes towards retinoscopy and (b) the relative accuracy of dedicated retinoscopes compared to combined types in which changing the bulb allows use in spot or streak mode. An online British survey received responses from 298 optometrists. Decision tree analyses revealed that optometrists working in multiple practices tended to rely less on retinoscopy than those in the independent sector. Only half of the respondents used dynamic retinoscopy. The majority, however, agreed that retinoscopy was an important test. The University attended also influenced the type of retinoscope used and the use of autorefractors. Combined retinoscopes were used most by the more recently qualified optometrists and few agreed that combined retinoscopes were less accurate. A trial indicated that combined and dedicated retinoscopes were equally accurate. Here, 4 optometrists (2 using spot and 2 using streak retinoscopes) tested one eye of 6 patients using combined and dedicated retinoscopes. This trial also demonstrated the utility of the relatively unknown ’15 degrees of freedom’ rule that exploits replication in factorial ANOVA designs to achieve sufficient statistical power when recruitment is limited. An opportunistic international survey explored the use of retinoscopy by 468 practitioners (134 ophthalmologists, 334 optometrists) attending contact related courses. Decision tree analyses found (a) no differences in the habits of optometrists and ophthalmologists, (b) differences in the reliance on retinoscopy and use of dynamic techniques across the participating countries and (c) some evidence that younger practitioners were using static and dynamic retinoscopy least often. In conclusion, this study has revealed infrequent use of static and dynamic retinoscopy by some optometrists, which may be the only means of determining refractive error and evaluating accommodation in patients with communication difficulties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Impaired facial expression recognition has been associated with features of major depression, which could underlie some of the difficulties in social interactions in these patients. Patients with major depressive disorder and age- and gender-matched healthy volunteers judged the emotion of 100 facial stimuli displaying different intensities of sadness and happiness and neutral expressions presented for short (100 ms) and long (2,000 ms) durations. Compared with healthy volunteers, depressed patients demonstrated subtle impairments in discrimination accuracy and a predominant bias away from the identification as happy of mildly happy expressions. The authors suggest that, in depressed patients, the inability to accurately identify subtle changes in facial expression displayed by others in social situations may underlie the impaired interpersonal functioning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focal points Over a six-week period in January and February 2002, 2ml samples were removed from all neonatal PN bags dispensed Samples were submitted for analysis of sodium, potassium and magnesium in triplicate by the hospital's clinical chemistry department using a Vitros Codac 950AT, dry slide, automated analyser Only 19.3, 7.1 and 30.4 per cent of measured sodium, potassium and magnesium concentrations respectively deviated by £5 per cent from stated bag concentrations The results indicate that it is possible that some electrolyte concentrations included in neonatal PN vary significantly from stated values

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the development of a WDM optical sensor array interrogation system using the radiation modes from a BFBG. We present results indicating 70nm bandwidth, with 0.2um RMS noise and a minimum WDM spacing of 30um. We further show the system to be polarization independent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate OneTouch® Verio™ test strip performance at hypoglycaemic blood glucose (BG) levels (<3.9mmol/L [<70mg/dL]) at seven clinical studies. Methods: Trained clinical staff performed duplicate capillary BG monitoring system tests on 700 individuals with type 1 and type 2 diabetes using blood from a single fingerstick lancing. BG reference values were obtained using a YSI 2300 STAT™ Glucose Analyzer. The number and percentage of BG values within ±0.83. mmol/L (±15. mg/dL) and ±0.56. mmol/L (±10. mg/dL) were calculated at BG concentrations of <3.9. mmol/L (<70. mg/dL), <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL). Results: At BG concentrations <3.9. mmol/L (<70. mg/dL), 674/674 (100%) of meter results were within ±0.83. mmol/L (±15. mg/dL) and 666/674 (98.8%) were within ±0.56. mmol/L (±10. mg/dL) of reference values. At BG concentrations <3.3. mmol/L (<60. mg/dL), and <2.8. mmol/L (<50. mg/dL), 358/358 (100%) and 270/270 (100%) were within ±0.56. mmol/L (±10. mg/dL) of reference values, respectively. Conclusion: In this analysis of data from seven independent studies, OneTouch Verio test strips provide highly accurate results at hypoglycaemic BG levels. © 2012 Elsevier Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study is to accurately distinguish Parkinson's disease (PD) participants from healthy controls using self-administered tests of gait and postural sway. Using consumer-grade smartphones with in-built accelerometers, we objectively measure and quantify key movement severity symptoms of Parkinson's disease. Specifically, we record tri-axial accelerations, and extract a range of different features based on the time and frequency-domain properties of the acceleration time series. The features quantify key characteristics of the acceleration time series, and enhance the underlying differences in the gait and postural sway accelerations between PD participants and controls. Using a random forest classifier, we demonstrate an average sensitivity of 98.5% and average specificity of 97.5% in discriminating PD participants from controls. © 2014 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implementation of a Monte Carlo simulation for the solution of population balance equations (PBEs) requires choice of initial sample number (N0), number of replicates (M), and number of bins for probability distribution reconstruction (n). It is found that Squared Hellinger Distance, H2, is a useful measurement of the accuracy of Monte Carlo (MC) simulation, and can be related directly to N0, M, and n. Asymptotic approximations of H2 are deduced and tested for both one-dimensional (1-D) and 2-D PBEs with coalescence. The central processing unit (CPU) cost, C, is found in a power-law relationship, C= aMNb0, with the CPU cost index, b, indicating the weighting of N0 in the total CPU cost. n must be chosen to balance accuracy and resolution. For fixed n, M × N0 determines the accuracy of MC prediction; if b > 1, then the optimal solution strategy uses multiple replications and small sample size. Conversely, if 0 < b < 1, one replicate and a large initial sample size is preferred. © 2015 American Institute of Chemical Engineers AIChE J, 61: 2394–2402, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of accurately controlling the position of a mobile robot using an external large volume metrology (LVM) instrument is presented in this article. By utilising an LVM instrument such as a laser tracker or indoor GPS (iGPS) in mobile robot navigation, many of the most difficult problems in mobile robot navigation can be simplified or avoided. Using the real-time position information from the laser tracker, a very simple navigation algorithm, and a low cost robot, 5mm repeatability was achieved over a volume of 30m radius. A surface digitisation scan of a wind turbine blade section was also demonstrated, illustrating possible applications of the method for manufacturing processes. Further, iGPS guidance of a small KUKA omni-directional robot has been demonstrated, and a full scale prototype system is being developed in cooperation with KUKA Robotics, UK. © 2011 Taylor & Francis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The accuracy of many aerospace structures is limited by the accuracy of assembly tooling which is in turn limited by the accuracy of the measurements used to set the tooling. Further loss of accuracy results from different rates of thermal expansion for the components and tooling. This paper describes improved tooling designs and setting processes which have the potential to significantly improve the accuracy of aerospace structures. The most advanced solution described is environmentally isolated interferometer networks embedded within tooling combined with active compensation of component pick-ups. This would eliminate environmental effects on measurements while also allowing compensation for thermal expansion. A more immediately realizable solution is the adjustment of component pick-ups using micrometer jacking screws allowing multilateration to be employed during the final stages of the setting process to generate the required offsets. Copyright © 2011 SAE International.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To test the practicality and effectiveness of cheap, ubiquitous, consumer-grade smartphones to discriminate Parkinson’s disease (PD) subjects from healthy controls, using self-administered tests of gait and postural sway. Background: Existing tests for the diagnosis of PD are based on subjective neurological examinations, performed in-clinic. Objective movement symptom severity data, collected using widely-accessible technologies such as smartphones, would enable the remote characterization of PD symptoms based on self-administered, behavioral tests. Smartphones, when backed up by interviews using web-based videoconferencing, could make it feasible for expert neurologists to perform diagnostic testing on large numbers of individuals at low cost. However, to date, the compliance rate of testing using smart-phones has not been assessed. Methods: We conducted a one-month controlled study with twenty participants, comprising 10 PD subjects and 10 controls. All participants were provided identical LG Optimus S smartphones, capable of recording tri-axial acceleration. Using these smartphones, patients conducted self-administered, short (less than 5 minute) controlled gait and postural sway tests. We analyzed a wide range of summary measures of gait and postural sway from the accelerometry data. Using statistical machine learning techniques, we identified discriminating patterns in the summary measures in order to distinguish PD subjects from controls. Results: Compliance was high all 20 participants performed an average of 3.1 tests per day for the duration of the study. Using this test data, we demonstrated cross-validated sensitivity of 98% and specificity of 98% in discriminating PD subjects from healthy controls. Conclusions: Using consumer-grade smartphone accelerometers, it is possible to distinguish PD from healthy controls with high accuracy. Since these smartphones are inexpensive (around $30 each) and easily available, and the tests are highly non-invasive and objective, we envisage that this kind of smartphone-based testing could radically increase the reach and effectiveness of experts in diagnosing PD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Large-scale mechanical products, such as aircraft and rockets, consist of large numbers of small components, which introduce additional difficulty for assembly accuracy and error estimation. Planar surfaces as key product characteristics are usually utilised for positioning small components in the assembly process. This paper focuses on assembly accuracy analysis of small components with planar surfaces in large-scale volume products. To evaluate the accuracy of the assembly system, an error propagation model for measurement error and fixture error is proposed, based on the assumption that all errors are normally distributed. In this model, the general coordinate vector is adopted to represent the position of the components. The error transmission functions are simplified into a linear model, and the coordinates of the reference points are composed by theoretical value and random error. The installation of a Head-Up Display is taken as an example to analyse the assembly error of small components based on the propagation model. The result shows that the final coordination accuracy is mainly determined by measurement error of the planar surface in small components. To reduce the uncertainty of the plane measurement, an evaluation index of measurement strategy is presented. This index reflects the distribution of the sampling point set and can be calculated by an inertia moment matrix. Finally, a practical application is introduced for validating the evaluation index.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of accurately controlling the position of a mobile robot using an external Large Volume Metrology (LVM) instrument is presented in this paper. Utilizing a LVM instrument such as the laser tracker in mobile robot navigation, many of the most difficult problems in mobile robot navigation can be simplified or avoided. Using the real- Time position information from the laser tracker, a very simple navigation algorithm, and a low cost robot, 5mm repeatability was achieved over a volume of 30m radius. A surface digitization scan of a wind turbine blade section was also demonstrated, illustrating possible applications of the method for manufacturing processes. © Springer-Verlag Berlin Heidelberg 2010.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The auditory evoked N1m-P2m response complex presents a challenging case for MEG source-modelling, because symmetrical, phase-locked activity occurs in the hemispheres both contralateral and ipsilateral to stimulation. Beamformer methods, in particular, can be susceptible to localisation bias and spurious sources under these conditions. This study explored the accuracy and efficiency of event-related beamformer source models for auditory MEG data under typical experimental conditions: monaural and diotic stimulation; and whole-head beamformer analysis compared to a half-head analysis using only sensors from the hemisphere contralateral to stimulation. Event-related beamformer localisations were also compared with more traditional single-dipole models. At the group level, the event-related beamformer performed equally well as the single-dipole models in terms of accuracy for both the N1m and the P2m, and in terms of efficiency (number of successful source models) for the N1m. The results yielded by the half-head analysis did not differ significantly from those produced by the traditional whole-head analysis. Any localisation bias caused by the presence of correlated sources is minimal in the context of the inter-individual variability in source localisations. In conclusion, event-related beamformers provide a useful alternative to equivalent-current dipole models in localisation of auditory evoked responses.