21 resultados para Abnormal items
Resumo:
The processing conducted by the visual system requires the combination of signals that are detected at different locations in the visual field. The processes by which these signals are combined are explored here using psychophysical experiments and computer modelling. Most of the work presented in this thesis is concerned with the summation of contrast over space at detection threshold. Previous investigations of this sort have been confounded by the inhomogeneity in contrast sensitivity across the visual field. Experiments performed in this thesis find that the decline in log contrast sensitivity with eccentricity is bilinear, with an initial steep fall-off followed by a shallower decline. This decline is scale-invariant for spatial frequencies of 0.7 to 4 c/deg. A detailed map of the inhomogeneity is developed, and applied to area summation experiments both by incorporating it into models of the visual system and by using it to compensate stimuli in order to factor out the effects of the inhomogeneity. The results of these area summation experiments show that the summation of contrast over area is spatially extensive (occurring over 33 stimulus carrier cycles), and that summation behaviour is the same in the fovea, parafovea, and periphery. Summation occurs according to a fourth-root summation rule, consistent with a “noisy energy” model. This work is extended to investigate the visual deficit in amblyopia, finding that area summation is normal in amblyopic observers. Finally, the methods used to study the summation of threshold contrast over area are adapted to investigate the integration of coherent orientation signals in a texture. The results of this study are described by a two-stage model, with a mandatory local combination stage followed by flexible global pooling of these local outputs. In each study, the results suggest a more extensive combination of signals in vision than has been previously understood.
Resumo:
Background: This pilot study aimed to investigate systemic and retinal vascular function and their relationship to circulatory markers of cardiovascular risk in early age-related macular degeneration (AMD) patients without any already diagnosed systemic vascular pathologies. Methods: Fourteen patients diagnosed with early AMD and 14 age- and gender-matched healthy controls underwent blood pressure, carotid intima-media thickness (C-IMT) and peripheral arterial stiffness measurements. Retinal vascular reactivity was assessed by means of dynamic retinal vessel analysis (DVA) using a modified protocol. Blood analyses were conducted for glutathione levels and plasma levels of total cholesterol (CHOL), high-density lipoprotein cholesterol (HDL-C), low-density lipoprotein cholesterol (LDL-C) and triglycerides (TG). Results: The AMD patients showed significantly greater C-IMT (p = 0.029) and augmentation index (AIx) (p = 0.042) than the age-matched controls. In addition, they demonstrated a shallower retinal arterial dilation slope (Slope AD) (p = 0.005) and a longer retinal venous reaction time (RT) to flickering light (p = 0.026). Blood analyses also revealed that AMD patients exhibited higher oxidized glutathione (GSSG) (p = 0.024), lower redox index (p = 0.043) and higher LDL-C (p = 0.033) levels than the controls. Venous RT parameter correlated positively with blood GSSG levels (r = 0.58, p = 0.038) in AMD subjects, but not in the controls (p > 0.05). Conclusions: Patients diagnosed with early AMD exhibit signs of systemic and retinal vascular alterations that correlated with known risk markers for future cardiovascular morbidity. © 2013 Springer-Verlag Berlin Heidelberg.
Resumo:
We report the abnormal photosensitivity effects leading to the formation of Type IA FBGs. We show the rate at which these gratings form is related to the intensity of the UV inscription laser. We report the first measurement of the reflection along the gratings’ length.
Resumo:
The properties of fiber Bragg gratings in hydrogenated fibers under conditions of ultraviolet overexposure were investigated. Abnormal spectral evolution of the regenerated grating following erasure of the initial type I grating was observed in the hydrogenated fibers. The regenerated grating also exhibited less temperature sensitivity and an 18 nm shift in the Bragg wavelength.
Resumo:
PURPOSE. To assess systemic and ocular vascular reactivity in response to warm and cold provocation in untreated patients with primary open-angle glaucoma and normal control subjects. METHODS. Twenty-four patients with primary open-angle glaucoma and 22 normal control subjects were subjected to a modified cold pressor test involving immersion of the right hand in 40°C warm water followed by 4°C cold water exposure, and finger and ocular blood flow were assessed by means of peripheral laser Doppler flowmetry and retinal flowmetry, respectively. Finger and body temperature as well as intraocular pressure, systemic blood pressure, systemic pulse pressure, heart rate, and ocular perfusion pressure were also monitored. RESULTS. The patients with glaucoma demonstrated an increase in diastolic blood pressure (P = 0.023), heart rate (P = 0.010), and mean ocular perfusion pressure (P = 0.039) during immersion of the tested hand in 40°C water. During cold provocation, the patients demonstrated a significant decrease in finger (P = 0.0003) and ocular blood flow (the parameter velocity measured at the temporal neuroretinal rim area; P = 0.021). Normal subjects did not demonstrate any blood flow or finger temperature changes during immersion of the tested hand in 40°C water (P > 0.05); however, they exhibited increases in systolic blood pressure (P = 0.034) and pulse pressure (P = 0.0009) and a decrease in finger blood flow (P = 0.0001) during cold provocation. In normal subjects, the ocular blood flow was unchanged during high- and low-temperature challenge. CONCLUSIONS. Cold provocation elicits a different blood pressure, and ocular blood flow response in patients with primary open-angle glaucoma compared with control subjects. These findings suggest a systemic autonomic failure and ocular vascular dysregulation in POAG patients.
Resumo:
Recommender system is a specific type of intelligent systems, which exploits historical user ratings on items and/or auxiliary information to make recommendations on items to the users. It plays a critical role in a wide range of online shopping, e-commercial services and social networking applications. Collaborative filtering (CF) is the most popular approaches used for recommender systems, but it suffers from complete cold start (CCS) problem where no rating record are available and incomplete cold start (ICS) problem where only a small number of rating records are available for some new items or users in the system. In this paper, we propose two recommendation models to solve the CCS and ICS problems for new items, which are based on a framework of tightly coupled CF approach and deep learning neural network. A specific deep neural network SADE is used to extract the content features of the items. The state of the art CF model, timeSVD++, which models and utilizes temporal dynamics of user preferences and item features, is modified to take the content features into prediction of ratings for cold start items. Extensive experiments on a large Netflix rating dataset of movies are performed, which show that our proposed recommendation models largely outperform the baseline models for rating prediction of cold start items. The two proposed recommendation models are also evaluated and compared on ICS items, and a flexible scheme of model retraining and switching is proposed to deal with the transition of items from cold start to non-cold start status. The experiment results on Netflix movie recommendation show the tight coupling of CF approach and deep learning neural network is feasible and very effective for cold start item recommendation. The design is general and can be applied to many other recommender systems for online shopping and social networking applications. The solution of cold start item problem can largely improve user experience and trust of recommender systems, and effectively promote cold start items.