52 resultados para rigid gas permeable lens materials
Resumo:
PURPOSE: To examine the optimum time at which fluorescein patterns of gas permeable lenses (GPs) should be evaluated. METHODS: Aligned, 0.2mm steep and 0.2mm flat GPs were fitted to 17 patients (aged 20.6±1.1 years, 10 male). Fluorescein was applied to their upper temporal bulbar conjunctiva with a moistened fluorescein strip. Digital slit lamp images (CSO, Italy) at 10× magnification of the fluorescein pattern viewed with blue light through a yellow filter were captured every 15s. Fluorescein intensity in central, mid peripheral and edge regions of the superior, inferior, temporal and nasal quadrants of the lens were graded subjectively using a +2 to -2 scale and using ImageJ software on the simultaneously captured images. RESULTS: Subjectively graded and objectively image analysed fluorescein intensity changed with time (p<0.001), lens region (centre, mid-periphery and edge: p<0.05) and there was interaction between lens region with lens fit (p<0.001). For edge band width, there was a significant effect of time (F=118.503, p<0.001) and lens fit (F=5.1249, p=0.012). The expected alignment, flat and steep fitting patterns could be seen from approximately after 30 to 180s subjectively and 15 to 105s in captured images. CONCLUSION: Although the stability of fluorescein intensity can start to decline in as little as 45s post fluorescein instillation, the diagnostic pattern of alignment, steep or flat fit is seen in each meridian by subjective observation from about 30s to 3min indicating this is the most appropriate time window to evaluate GP lenses in clinical practice.
Resumo:
Purpose: This study investigated how aberration-controlling, customised soft contact lenses corrected higher-order ocular aberrations and visual performance in keratoconic patients compared to other forms of refractive correction (spectacles and rigid gas-permeable lenses). Methods: Twenty-two patients (16 rigid gas-permeable contact lens wearers and six spectacle wearers) were fitted with standard toric soft lenses and customised lenses (designed to correct 3rd-order coma aberrations). In the rigid gas-permeable lens-wearing patients, ocular aberrations were measured without lenses, with the patient's habitual lenses and with the study lenses (Hartmann-Shack aberrometry). In the spectacle-wearing patients, ocular aberrations were measured both with and without the study lenses. LogMAR visual acuity (high-contrast and low-contrast) was evaluated with the patient wearing their habitual correction (of either spectacles or rigid gas-permeable contact lenses) and with the study lenses. Results: In the contact lens wearers, the habitual rigid gas-permeable lenses and customised lenses provided significant reductions in 3rd-order coma root-mean-square (RMS) error, 3rd-order RMS and higher-order RMS error (p ≤ 0.004). In the spectacle wearers, the standard toric lenses and customised lenses significantly reduced 3rd-order RMS and higher-order RMS errors (p ≤ 0.005). The spectacle wearers showed no significant differences in visual performance measured between their habitual spectacles and the study lenses. However, in the contact lens wearers, the habitual rigid gas-permeable lenses and standard toric lenses provided significantly better high-contrast acuities compared to the customised lenses (p ≤ 0.006). Conclusions: The customised lenses provided substantial reductions in ocular aberrations in these keratoconic patients; however, the poor visual performances achieved with these lenses are most likely to be due to small, on-eye lens decentrations. © 2014 The College of Optometrists.
Resumo:
It is an Olympic year and we have just witnessed the fantastic games hosted by Rio de Janeiro. Well done to team USA for winning the most medals overall but also well done to so many other nations and individuals who performed so well or were ambassadors in other ways. Teenage swimmer Yusra Mardini who swam for the refugee team and South Africa's Wayde van Niekerk who broke the longstanding 400 m record of Michael Johnson that has stood since 1999. Of course, we must mention sprinter Usain Bolt and swimmer Michael Phelps, who have now transcended superstar status and entered a new level of icon. My personal highlight was the sportsmanship witnessed in the 5000 m when American Abbey D’Agostino was accidentally felled by New Zealand runner Nikki Hamblin. D’Agostino helped Hamblin back to her feet but slumped to the track after realising her own injury. Hamblin helped her up and stayed with her so that both completed the race. The International Olympic Committee has awarded both with the prestigious Pierre de Coubertin award, also known as the International Fair Play Trophy. Fair play is of paramount importance in publishing in peer-reviewed papers. At CLAE we try and maintain, as do other journals, this by ensuring double blind peer review and allowing authors to select the most appropriate handling editor for their submission. Our handling editors are placed across the world (2 in Europe, 1 in the Americas, 1 in Australia and 1 in Asia) and part of their role is to encourage submissions from their region. Over the last decade we certainly have seen more and more papers from places that haven’t previously published in CLAE. In this issue of CLAE we have a true international blend of papers. We have papers from authors from the UK, USA, Iran, Jordan, France, Poland, Turkey, Nigeria, France, Spain and Brazil. I think it's a testament to the continued success of the journal that we are attracting new writers from so many parts of the world and retain papers from more established authors and research centres. We do continue to attract many weaker papers that are rejected early in the review process. Often these will be unexceptional case reports or papers describing a surgical technique. Case reports are published but only those that offer something original and especially those with interesting photographs. In this issue you will see Professor James Wolffsohn (UK) has an interesting paper around a lot of the focus of his recent research activity into clinical evaluation of methods of correcting presbyopia. In this paper he highlights predictors to aid success of presbyopic contact lenses. If you have been involved in any clinical work or research in the field of dry eye disease then you will know well the CLDEQ (Contact Lens Dry Eye Questionnaire) devised by Robin Chalmers and her colleagues (USA). This issue of CLAE details the latest research using the CLDEQ-8 (the 8 item version of the CLDEQ). The Shahroud Eye Cohort Study has produced many papers already and in this issue we see Fotouhi Akbar (Iran) looking at changes in central and peripheral corneal thickness over a five year period. These days we use a lot of new instrumentation, such as optical low-coherence reflectometry. In this issue Emre Güler (Turkey) compares that to a new optical biometry unit. Dry eye is more common and in this issue we see a study by Oluyemi Fasina (Nigeria) to investigate the disease in adults in South-West Nigeria. The TearLab™ is now commonly used to investigate osmolarity and Dorota Szczesna-Iskander (Poland) looks at measurement variability of this device. Following the theme of dry eyes and tear testing Renaud Laballe (France) looks at the use of scleral lenses as a reservoir-based ocular therapeutic system. In this issue we have a couple of papers looking at different aspects of keratoconus. Magdalena Popiela (UK) looks at demographics of older keratoconic patients in Wales, Faik Orucoglu (Turkey) reports a novel scoring system for distinguishing keratoconus from normal eyes, Gonzalo Carracedo (Spain) reports the effect of rigid gas permeable lens wear on dry eye in keratoconus and Hatice Nur Colak (Turkey) compares topographic and aberrations in keratoconus. Other interesting papers you will find are Mera Haddad (Jordan) investigates contact lens prescribing in Jordan, Camilla Fraga Amaral (Brazil) offers a report on the use of ocular prosthetics, Naveed Ahmed Khan (Malaysia) reports of the use of dimethyl sulfoxide in contact lens disinfectant and Michael Killpartrick (UK) offers a short piece with some useful advice on contamination risk factors that may occur from the posterior surface of disposable lenses. So for this issue I would say that the Gold Medal for biggest contribution in terms of papers has to go to Turkey. I could have awarded it to the UK too, but Turkey has three full papers and the UK has two plus one short communication. Turkey is also one of the countries that has shown the largest increase in submissions over the last decade. Finally, welcome aboard to our newest Editorial Board Member Nicole Carnt from Australia. Nicole has been an active researcher for many years and acted as a reviewer for CLAE many times in the past. We look forward to working with you.
Resumo:
Purpose: To develop a new schematic scheme for efficiently recording the key parameters of gas permeable contact lens (GP) fits based on current consensus. Methods: Over 100 established GP fitters and educators met to discuss the parameters proposed in educational material for evaluating GP fit and concluded on the key parameters that should be recorded. The accuracy and variability of evaluating the fluorescein pattern of GP fit was determined by having 35 experienced contact lens practitioners from across the world, grading 5 images of a range of fits and the topographer simulation of the same fits, in random, order using the proposed scheme. The accuracy of the grading was compared to objective image analysis of the fluorescein intensity of the same images. Results: The key information to record to adequately describe the fit of an GP was agreed as: the manufacturer, brand and lens parameters; settling time; comfort on a 5 point scale; centration; movement on blink on a ±2 scale; and the Primary Fluorescein Pattern in the central, mid-peripheral and edge regions of the lens averaged along the horizontal and vertical lens axes, on a ±2 scale. On average 50-60% of practitioners selected the median grade when subjectively rating fluorescein intensity and this was correlated to objective quantification (r= 0.602, p< 0.001). Objective grading suggesting horizontal median fluorescein intensity was generally symmetrical, as was the vertical meridian, but this was not the case for subjective grading. Simulated fluorescein patterns were subjectively and objectively graded as being less intense than real photographs (p< 0.01). Conclusion: GP fit recording can be standardised and simplified to enhance GP practice. © 2013 British Contact Lens Association.
Resumo:
Purpose: To compare monochromatic aberrations of keratoconic eyes when uncorrected, corrected with spherically-powered RGP (rigid gas-permeable) contact lenses and corrected using simulations of customised soft contact lenses for different magnitudes of rotation (up to 15°) and translation (up to 1mm) from their ideal position. Methods: The ocular aberrations of examples of mild, moderate and severe keratoconic eyes were measured when uncorrected and when wearing their habitual RGP lenses. Residual aberrations and point-spread functions of each eye were simulated using an ideal, customised soft contact lens (designed to neutralise higher-order aberrations, HOA) were calculated as a function of the angle of rotation of the lens from its ideal orientation, and its horizontal and vertical translation. Results: In agreement with the results of other authors, the RGP lenses markedly reduced both lower-order aberrations and HOA for all three patients. When compared with the RGP lens corrections, the customised lens simulations only provided optical improvements if their movements were constrained within limits which appear to be difficult to achieve with current technologies. Conclusions: At the present time, customised contact lens corrections appear likely to offer, at best, only minor optical improvements over RGP lenses for patients with keratoconus. If made in soft materials, however, these lenses may be preferred by patients in term of comfort. © 2012 The College of Optometrists.
Resumo:
The contact lens represents a well-established important class of biomaterials. This thesis brings together the literature, mostly Japanese and American patents, concerned with an important group of polymers, `rigid gas permeable contact lens materials'. A comparison is made of similarities in the underlying chemical themes, centring on the use of variants of highly branched siloxy compounds with polymerizable methacrylate groups. There is a need for standard techniques to assess laboratory behaviour in relation to in vitro performance. A major part of the present work is dedicated to the establishment of such standardised techniques. It is apparent that property design requirements in this field (i.e. oxygen permeability, surface and mechanical properties) are to some extent conflicting. In principle, the structural approaches used to obtain high oxygen permeability lead to surface properties that are less than ideal in terms of compatibility with tears. PMMA is known to have uniquely good (but not perfect) surface properties in this respect; it has been used as a starting point in attempting to design new materials that possess a more acceptable compromise of transport and surface properties for ocular use. Initial examination of the oxygen permeabilities of relatively simple alkyl methacrylates, show that butyl methacrylate which has a permeability some fifty times greater than PMMA, represents an interesting and hitherto unexplored group of materials for ophthalmic applications. Consideration was similarly given to surface modification techniques that would produce materials having the ability to sustain coherent tear film in the eye without markedly impairing oxygen transport properties. Particular attention is paid to the use of oxygen plasma techniques in this respect. In conclusion, similar design considerations were applied to an extended wear hydrogel lens material in an attempt to overcome mechanical stability deficiencies which manifest themselves lq`in vivo' but not `in vitro'. A relatively simple structure modification, involving steric shielding of the amide substituent group, proved to be an effective solution to the problem.
Resumo:
Interpenetrating polymer networks (lPN's), have been defined as a combination of two polymers each in network form, at least one of which has been synthesised and / or crosslinked in the presence of the other. A semi-lPN, is formed when only one of the polymers in the system is crosslinked, the other being linear. lPN's have potential advantages over homogeneous materials presently used in biomedical applications, in that their composite nature gives them a useful combination of properties. Such materials have potential uses in the biomedical field, specifically for use in hard tissue replacements, rigid gas permeable contact lenses and dental materials. Work on simply two or three component systems in both low water containing lPN's supplemented by the study of hydrogels (water swollen hydrophilic polymers) can provide information useful in the future development of more complex systems. A range of copolymers have been synthesised using a variety of methacrylates and acrylates. Hydrogels were obtained by the addition of N-vinyl pyrrolidone to these copolymers. A selection of interpenetrants were incorporated into the samples and their effect on the copolymer properties was investigated. By studying glass transition temperatures, mechanical, surface, water binding and oxygen permeability properties samples were assessed for their suitability for use as biomaterials. In addition copolymers containing tris-(trimethylsiloxy)-y-methacryloxypropyl silane, commonly abbreviated to 'TRlS', have been investigated. This material has been shown to enhance oxygen permeability, a desirable property when considering the design of contact lenses. However, 'TRIS' has a low polar component of surface free energy and hence low wettability. Copolymerisation with a range of methacrylates has shown that significant increases in surface wettability can be obtained without a detrimental effect on oxygen permeability. To further enhance to surface wettability 4-methacryloxyethyl trimellitic anhydride was incorporated into a range of promising samples. This study has shown that by careful choice of monomers it is possible to synthesise polymers that possess a range of properties desirable in biomedical applications.
Resumo:
What is meant by the term ‘specialist contact lens fitting’? Or put another way, what would be considered non-specialist contact lens fitting? Is there such a thing as routine contact lens fitting? Soft or silicone hydrogel fitting for daily wear would probably be considered as routine contact lens fitting, but would extended or flexible wear remain in the same category or would they be considered a specialist fit? Different eras will classify different products as being ‘specialist’. Certainly twenty years ago soft toric contact lenses were considered as being speciality lenses but today would be thought of as routine lenses. Conversely, gas permeable lenses were thought of as mainstream twenty years ago but now are considered as speciality lenses. Although this would not be the same globally, as in some countries (such as Netherlands, France and Japan) gas permeable lens fitting remains popular and is not on the decline as in other countries (Canada, Australia and Sweden) [1]. Bandage soft lenses applied after surface laser refractive procedures would be considered as therapeutic lenses but in reality they are just plano thin hydrogel lenses worn constantly for 3–4 days to allow the underlying epithelium to convalesce and are then removed [2]. Some patients find that wearing hydrogel lenses during periods when they suffer from seasonal allergies actually improves their ocular comfort as the contact lens acts as a barrier to the allergen [3] and [4]. Scleral lenses have long been considered speciality lenses, apart from a time when they were the only lenses available but at that time all contact lens work would have been considered speciality practice! Nowadays we see the advent of mini-scleral designs and we see large diameter gas permeable lenses too. It is possible that these lenses increase the popularity of gas permeable lenses again and they become more main stream. So it would seem that the lines between routine and speciality contact lens fitting are not clear. Whether a lens is classed a specialist fit or not would depend on the lens type, why it was fitted, where in the world the fitting was being done and even the era in which it was fitted. This begs the question as to what would be considered entry level knowledge in contact lens fitting. This may not be an issue for most BCLA members or CLAE readers but certainly would be for bodies such as the College of Optometrists (UK) or the Association of British Dispensing Opticians when they are planning the final registration examinations for budding practitioners or when planning the level of higher level qualifications such as College Certificates or Diplomas. Similarly for training institutions when they are planning their course content. This becomes even trickier when trying to devise a qualification that spans across many countries, like the European Diploma in Optometry and Optics. How do we know if the training and examination level is correct? One way would be to analyse things when they go wrong and if patterns of malpractice are seen then maybe that could be used as an indicator to more training being needed. There were 162 Fitness to Practice Hearing at the General Optical Council between 2001 and 2010. Forty-seven of these were clinically related case, 39 fraud related, and 76 others. Of the clinical ones only 3 were contact lens related. So it would appear that as whole, in the profession, contact lens clinical skills are not being questioned too often (although it seems a few of us can’t keep our hands out the cookie jar!).
Resumo:
Purpose: To assess visual performance and ocular aberrations in keratoconic patients using toric soft contact lenses (SCL), rigid-gas-permeable (RGP) contact lenses and spectacle lens correction. Methods: Twenty-two keratoconus patients (16 RGP lens wearers and six spectacle wearers) were fitted with toric SCL. Ocular aberrations were measured with and without the patient's habitual RGP lenses and with the SCL in place. In the spectacle wearers, aberrations were measured with and without the SCL. Visual performance (high- and low-contrast visual acuity) was evaluated with the patient's habitual correction and with the SCL. Results: In the RGP lens wearers both the habitual lenses and the toric SCL significantly reduced coma, trefoil, 3rd-order, 4th-order cylinder and higher-order root-mean-square (RMS) aberrations (p≤0.015). In the spectacle wearers the toric SCL significantly reduced coma, 3rd-order and higher-order RMS aberrations (p≤0.01). The patients' habitual RGP lenses gave better low-contrast acuity (p≤0.006) compared to the toric SCL; however, no significant difference was found between lens types for high-contrast acuity (p=0.10). In the spectacle wearers no significant differences in visual performance measurements were found between the patients' spectacles and the toric SCL (p≥0.06). Conclusion: The results show that RGP lenses provided superior visual performances and greater reduction of 3rd-order aberrations compared to toric SCL in this group of keratoconic patients. In the spectacle-wearing group, visual performance with the toric SCL was found to be comparable to that measured with spectacles. Nevertheless, with the exception of spherical aberration, the toric SCL were successful in significantly reducing uncorrected higher-order aberrations. Ophthalmic & Physiological Optics © 2012 The College of Optometrists.
Resumo:
Purpose: To describe and validate bespoke software designed to extract morphometric data from ciliary muscle Visante Anterior Segment Optical Coherence Tomography (AS-OCT) images. Method: Initially, to ensure the software was capable of appropriately applying tiered refractive index corrections and accurately measuring orthogonal and oblique parameters, 5 sets of custom-made rigid gas-permeable lenses aligned to simulate the sclera and ciliary muscle were imaged by the Visante AS-OCT and were analysed by the software. Human temporal ciliary muscle data from 50 participants extracted via the internal Visante AS-OCT caliper method and the software were compared. The repeatability of the software was also investigated by imaging the temporal ciliary muscle of 10 participants on 2 occasions. Results: The mean difference between the software and the absolute thickness measurements of the rigid gas-permeable lenses were not statistically significantly different from 0 (t = -1.458, p = 0.151). Good correspondence was observed between human ciliary muscle measurements obtained by the software and the internal Visante AS-OCT calipers (maximum thickness t = -0.864, p = 0.392, total length t = 0.860, p = 0.394). The software extracted highly repeatable ciliary muscle measurements (variability ≤6% of mean value). Conclusion: The bespoke software is capable of extracting accurate and repeatable ciliary muscle measurements and is suitable for analysing large data sets.
Resumo:
Purpose. We investigated structural differences in the fatty acid profiles of lipids extracted from ex vivo contact lenses by using gas chromatography mass spectrometry (GCMS). Two lens materials (balafilcon A or lotrafilcon A) were worn on a daily or continuous wear schedule for 30 and 7 days. Methods. Lipids from subject-worn lenses were extracted using 1:1 chloroform: methanol and transmethylated using 5% sulfuric acid in methanol. Fatty acid methyl esters (FAMEs) were collected using hexane and water, and analyzed by GCMS (Varian 3800 GC, Saturn 2000 MS). Results. The gas chromatograms of lens extracts that were worn on a continuous wear schedule showed two predominant peaks, C16:0 and C18:0, both of which are saturated fatty acids. This was the case for balafilcon A and lotrafilcon A lenses. However, the gas chromatograms of lens extracts that were worn on a daily wear schedule showed saturated (C16:0, C18:0) and unsaturated (C16:1 and C18:1) fatty acids. Conclusions. Unsaturated fatty acids are degraded during sleep in contact lenses. Degradation occurred independently of lens material or subject-to-subject variability in lipid deposition. The consequences of lipid degradation are the production of oxidative products, which may be linked to contact lens discomfort. © 2014 The Association for Research in Vision and Ophthalmology, Inc.
Resumo:
The project objective was to develop a reliable selection procedure to match contact lens materials with individual wearers by the identification of a biochemical marker for assessment of in-eye performance of contact lenses. There is a need for such a procedure as one of the main reasons for contact lens wearers ceasing wearing contact lenses is poor end of day comfort i.e. the lenses become intolerable to the wearer as the day progresses. The selection of an optimal material for individual wearers has the potential benefit to reduce drop Qut, hence increasing the overall contact lens population, and to improve contact lens comfort for established wearers. Using novel analytical methods and statistical techniques, we were able to investigate the interactions between the composition of the tear film and of the biofilm deposited on the contact lenses and contact lens performance. The investigations were limited to studying the lipid components of the tear film; the lipid layer, which plays a key role in preventing evaporation and stabilising the tear film, has been reported to be significantly thinner and of different mixing characteristics during contact lens wear. Different lipid families were found to influence symptomatology, in vivo tear film structure and stability as well as ocular integrity. Whereas the symptomatology was affected by both the tear film lipid composition and the nature of the lipid deposition, the structure of the tear film and its stability were mainly influenced by the tear film lipid composition. The ocular integrity also appeared to be influenced by the nature of the lipid deposition. Potential markers within the lipid species have been identified and could be applied as follows: When required in order to identify a problematic wearer or to match the contact lens material to the contact lens wearer, tear samples collected by the clinician could be dispatched to an analytical laboratory where lipid analysis could be carried out by HPLC. A colorimetric kit based on the lipid markers could also be developed and used by clinician directly in the practice; such a kit would involve tear sampling and classification according to the colour into "Problem", "Border line" and "Good" contact lens wearers groups. A test kit would also have wider scope for marketing in other areas such as general dry-eye pathology.
Resumo:
The primary objective of this research has been to determine the potential of fluorescence spectroscopy as a method for analysis of surface deposition on contact lenses. In order to achieve this it was first necessary to ascertain whether fluorescence analysis would be able to detect and distinguish between protein and lipid deposited on a lens surface. In conjunction with this it was important to determine the specific excitation wavelengths at which these deposited species were detected with the greatest sensitivity. Experimental observations showed that an excitation wavelength of 360nm would detect lipid deposited on a lens surface, and an excitation wavelength of 280nm would detect and distinguish between protein and lipid deposited on a contact lens. It was also very important to determine whether clean unspoilt lenses showed significant levels of fluorescence themselves. Fluorescence spectra recorded from a variety of unworn contact lenses at excitation wavelengths of 360nm and 280nm indicated that most contact lens materials do not fluoresce themselves to any great extent. Following these initial experiments various clinically and laboratory based studies were performed using fluorescence spectroscopy as a method of analysing contact lens deposition levels. The clinically based studies enabled analysis of contact lenses with known wear backgrounds to be rapidly and individually analysed following discontinuation of wear. Deposition levels in the early stages of lens wear were determined for various lens materials. The effect of surfactant cleaning on deposition levels was also investigated. The laboratory based studies involved comparing some of the in vivo results with those of identical lenses that had been spoilt using an in vitro method. Finally, an examination of lysosyme migration into and out of stored ionic high water contact lenses was made.
Resumo:
Fischer-Tropsch synthesis (FTS) is a process which converts syn-gas (H2 and CO) to synthetic liquid fuels and valuable chemicals. Thermal gasification of biomass represents a convenient route to produce syn-gas from intractable materials particularly those derived from waste that are not cost effective to process for use in biocatalytic or other milder catalytic processes. The development of novel catalysts with high activity and selectivity is desirable as it leads to improved quality and value of FTS products. This review paper summarises recent developments in FT-catalyst design with regards to optimising catalyst activity and selectivity towards synthetic fuels. © 2014 the Partner Organisations.