18 resultados para constructive alignment
Resumo:
Primary data obtained from unionized employees in Singapore were used to examine P. A. Bamberger, A. N. Kluger, and R. Suchard's (1999) integrative model of the antecedents and outcomes of union commitment. Structural equation modeling results revealed support for their integrative model. Specifically, the results revealed the influence of job satisfaction on union loyalty to be indirect through organizational commitment. However, the union-related antecedents (union socialization and union instrumentality) were both directly and indirectly related to union loyalty through pro-union attitudes. In addition, union loyalty was related to the individually and organizationally directed union citizenship behavior dimensions. Limitations of the study and implications of the findings are discussed.
Resumo:
Phakometric measurements of corneal and crystalline lens surface alignment are influenced by corneal asymmetry in which the corneal apex does not coincide with the limbal centre. The purpose of this study was to determine the horizontal separation (e) between these corneal landmarks. Measurements were made in 60 normal eyes (30 subjects) using the Orbscan Ilz corneal analysis workstation. Our results show that both corneal landmarks typically coincide, so that e = 0, but that inter-subject variations of about ±1 mm can be expected (so that the corneal apex may fall nasal or temporal to the visual axis). This suggests that no correction for corneal asymmetry is required when estimating average amounts of ocular alignment from samples of eyes but that the measurement of e is strongly recommended for measurements in individual eyes. © 2004 The College of Optometrists.
Resumo:
Measurements (autokeratometry, A-scan ultrasonography and video ophthalmophakometry) of ocular surface radii, axial separations and alignment were made in the horizontal meridian of nine emmetropes (aged 20-38 years) with relaxed (cycloplegia) and active accommodation (mean ± 95% confidence interval: 3.7 ± 1.1 D). The anterior chamber depth (-1.5 ± 0.3 D) and both crystalline lens surfaces (front 3.1 ± 0.8 D; rear 2.1 ± 0.6 D) contributed to dioptric vergence changes that accompany accommodation. Accommodation did not alter ocular surface alignment. Ocular misalignment in relaxed eyes is mainly because of eye rotation (5.7 ± 1.6° temporally) with small amounts of lens tilt (0.2 ± 0.8° temporally) and decentration (0.1 ± 0.1 mm nasally) but these results must be viewed with caution as we did not account for corneal asymmetry. Comparison of calculated and empirically derived coefficients (upon which ocular surface alignment calculations depend) revealed that negligible inherent errors arose from neglect of ocular surface asphericity, lens gradient refractive index properties, surface astigmatism, effects of pupil size and centration, assumed eye rotation axis position and use of linear equations for analysing Purkinje image shifts. © 2004 The College of Optometrists.
Resumo:
Ophthalmophakometric measurements of ocular surface radius of curvature and alignment were evaluated on physical model eyes encompassing a wide range of human ocular dimensions. The results indicated that defocus errors arising from imperfections in the ophthalmophakometer camera telecentricity and light source collimation were smaller than experimental errors. Reasonable estimates emerged for anterior lens surface radius of curvature (accuracy: 0.02–0.10 mm; precision 0.05–0.09 mm), posterior lens surface radius of curvature (accuracy: 0.10–0.55 mm; precision 0.06–0.20 mm), eye rotation (accuracy: 0.00–0.32°; precision 0.06–0.25°), lens tilt (accuracy: 0.00–0.33°; precision 0.05–0.98°) and lens decentration (accuracy: 0.00–0.07 mm; precision 0.00–0.07 mm).
Resumo:
We describe a non-invasive phakometric method for determining corneal axis rotation relative to the visual axis (β) together with crystalline lens axis tilt (α) and decentration (d) relative to the corneal axis. This does not require corneal contact A-scan ultrasonography for the measurement of intraocular surface separations. Theoretical inherent errors of the method, evaluated by ray tracing through schematic eyes incorporating the full range of human ocular component variations, were found to be larger than the measurement errors (β < 0.67°, α < 0.72° and d < 0.08 mm) observed in nine human eyes with known ocular component dimensions. Intersubject variations (mean ± S.D.: β = 6.2 ± 3.4° temporal, α = 0.2 ± 1.8° temporal and d = 0.1 ± 0.1 mm temporal) and repeatability (1.96 × S.D. of difference between repeat readings: β ± 2.0°, α ± 1.8° and d ± 0.2 mm) were studied by measuring the left eyes of 45 subjects (aged 18-42 years, 29 females and 16 males, 15 Caucasians, 29 Indian Asians, one African, refractive error range -7.25 to +1.25 D mean spherical equivalent) on two occasions. © 2005 The College of Optometrists.
Resumo:
We examined the effect of grouping by the alignment of implicit axes on the perception of multiple shapes, using a patient (GK) who shows simultanagnosia as part of Blint's syndrome. Five experiments demonstrated that: (1) GK was better able to judge the orientation of a global configuration if the constituent local shapes were aligned with their major axes than if they were aligned with their edges; (2) this axis information was used implicitly, since GK was unable to discriminate between configurations of axis-aligned and edge-aligned shapes; (3) GK's sensitivity to axis-alignment persisted even when the orientations of local shapes were kept constant, indicating some form of cooperative effect between the local elements; (4) axis-alignment of shapes also facilitated his ability to discriminate single-item from multi-item configurations; (5) the effect of axis-alignment could be attributed, at least partially, to the degree to which there was matching between the orientations of local shapes and the global configuration. Taken together, the results suggest that axis-based grouping can support the selection of multiple objects.
Resumo:
Information systems are corporate resources, therefore information systems development must be aligned with corporate strategy. This thesis proposes that effective strategic alignment of information systems requires information systems development, information systems planning and strategic management to be united. Literature in these areas is examined, breaching the academic boundaries which separate these areas, to contribute a synthesised approach to the strategic alignment of information systems development. Previous work in information systems planning has extended information systems development techniques, such as data modelling, into strategic planning activities, neglecting techniques of strategic management. Examination of strategic management in this thesis, identifies parallel trends in strategic management and information systems development; the premises of the learning school of strategic management are similar to those of soft systems approaches to information systems development. It is therefore proposed that strategic management can be supported by a soft systems approach. Strategic management tools and techniques frame individual views of a strategic situation; soft systems approaches can integrate these diverse views to explore the internal and external environments of an organisation. The information derived from strategic analysis justifies the need for an information system and provides a starting point for information systems development. This is demonstrated by a composite framework which enables each information system to be justified according to its direct contribution to corporate strategy. The proposed framework was developed through action research conducted in a number of organisations of varying types. This suggests that the framework can be widely used to support the strategic alignment of information systems development, thereby contributing to organisational success.
Resumo:
Geometric information relating to most engineering products is available in the form of orthographic drawings or 2D data files. For many recent computer based applications, such as Computer Integrated Manufacturing (CIM), these data are required in the form of a sophisticated model based on Constructive Solid Geometry (CSG) concepts. A recent novel technique in this area transfers 2D engineering drawings directly into a 3D solid model called `the first approximation'. In many cases, however, this does not represent the real object. In this thesis, a new method is proposed and developed to enhance this model. This method uses the notion of expanding an object in terms of other solid objects, which are either primitive or first approximation models. To achieve this goal, in addition to the prepared subroutine to calculate the first approximation model of input data, two other wireframe models are found for extraction of sub-objects. One is the wireframe representation on input, and the other is the wireframe of the first approximation model. A new fast method is developed for the latter special case wireframe, which is named the `first approximation wireframe model'. This method avoids the use of a solid modeller. Detailed descriptions of algorithms and implementation procedures are given. In these techniques utilisation of dashed line information is also considered in improving the model. Different practical examples are given to illustrate the functioning of the program. Finally, a recursive method is employed to automatically modify the output model towards the real object. Some suggestions for further work are made to increase the domain of objects covered, and provide a commercially usable package. It is concluded that the current method promises the production of accurate models for a large class of objects.
Resumo:
There are been a resurgence of interest in the neural networks field in recent years, provoked in part by the discovery of the properties of multi-layer networks. This interest has in turn raised questions about the possibility of making neural network behaviour more adaptive by automating some of the processes involved. Prior to these particular questions, the process of determining the parameters and network architecture required to solve a given problem had been a time consuming activity. A number of researchers have attempted to address these issues by automating these processes, concentrating in particular on the dynamic selection of an appropriate network architecture.The work presented here specifically explores the area of automatic architecture selection; it focuses upon the design and implementation of a dynamic algorithm based on the Back-Propagation learning algorithm. The algorithm constructs a single hidden layer as the learning process proceeds using individual pattern error as the basis of unit insertion. This algorithm is applied to several problems of differing type and complexity and is found to produce near minimal architectures that are shown to have a high level of generalisation ability.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Resumo:
Dynamic supply chain alignment: a new business model for peak performance in enterprise supply chains across all geographies John Gattorna and friends, Farnham, Gower Publishing, 2009, 440pp., £60, ISBN 978-0-566-08822-3.
Resumo:
A generalization of the Gram-Schmidt procedure is achieved by providing equations for updating and downdating oblique projectors. The work is motivated by the problem of adaptive signal representation outside the orthogonal basis setting. The proposed techniques are shown to be relevant to the problem of discriminating signals produced by different phenomena when the order of the signal model needs to be adjusted. © 2007 IOP Publishing Ltd.
Resumo:
Subunit vaccine discovery is an accepted clinical priority. The empirical approach is time- and labor-consuming and can often end in failure. Rational information-driven approaches can overcome these limitations in a fast and efficient manner. However, informatics solutions require reliable algorithms for antigen identification. All known algorithms use sequence similarity to identify antigens. However, antigenicity may be encoded subtly in a sequence and may not be directly identifiable by sequence alignment. We propose a new alignment-independent method for antigen recognition based on the principal chemical properties of protein amino acid sequences. The method is tested by cross-validation on a training set of bacterial antigens and external validation on a test set of known antigens. The prediction accuracy is 83% for the cross-validation and 80% for the external test set. Our approach is accurate and robust, and provides a potent tool for the in silico discovery of medically relevant subunit vaccines.
Resumo:
This thesis describes the design and development of an eye alignment/tracking system which allows self alignment of the eye’s optical axis with a measurement axis. Eye alignment is an area of research largely over-looked, yet it is a fundamental requirement in the acquisition of clinical data from the eye. New trends in the ophthalmic market, desiring portable hand-held apparatus, and the application of ophthalmic measurements in areas other than vision care have brought eye alignment under new scrutiny. Ophthalmic measurements taken in hand-held devices with out an clinician present requires alignment in an entirely new set of circumstances, requiring a novel solution. In order to solve this problem, the research has drawn upon eye tracking technology to monitor the eye, and a principle of self alignment to perform alignment correction. A handheld device naturally lends itself to the patient performing alignment, thus a technique has been designed to communicate raw eye tracking data to the user in a manner which allows the user to make the necessary corrections. The proposed technique is a novel methodology in which misalignment to the eye’s optical axis can be quantified, corrected and evaluated. The technique uses Purkinje Image tracking to monitor the eye’s movement as well as the orientation of the optical axis. The use of two sets of Purkinje Images allows quantification of the eye’s physical parameters needed for accurate Purkinje Image tracking, negating the need for prior anatomical data. An instrument employing the methodology was subsequently prototyped and validated, allowing a sample group to achieve self alignment of their optical axis with an imaging axis within 16.5-40.8 s, and with a rotational precision of 0.03-0.043°(95% confidence intervals). By encompassing all these factors the technique facilitates self alignment from an unaligned position on the visual axis to an aligned position on the optical axis. The consequence of this is that ophthalmic measurements, specifically pachymetric measurements, can be made in the absence of an optician, allowing the use of ophthalmic instrumentation and measurements in health professions other than vision care.