21 resultados para Visual Analog Scale
Resumo:
Chronic pelvic pain (CPP), a common cause of disability in women, is a condition best viewed in the biopsychosocial framework. Psychological interventions are frequently considered alongside medical and surgical treatments. Our objective was to evaluate the effectiveness of psychological therapies for the treatment of CPP. Electronic literature searches were conducted in Medline, Embase, PsycInfo and DARE databases from database inception to April 2010. Reference lists of selected articles were searched for further articles. The studies selected were randomized controlled trials of psychological therapies in patients with CPP compared with no treatment, standard gynecological treatment or another form of psychological therapy. Two reviewers independently selected articles without language restrictions and extracted data covering study characteristics, study quality and results. Reduction in pain, measured using visual analog scales or other measurements, was the main outcome measure. Of the 107 citations identified, four studies satisfied the inclusion criteria. Compared with no psychological intervention, therapy produced a standardized mean pain score of -3.27 [95% confidence interval (CI) -4.52 to -2.02] and 1.11 (95% CI -0.05 to 2.27) at 3 months and -3.95 (95% CI -5.35 to -2.55) and 0.54 (95% CI -0.78 to 1.86) at 6 months and greater, based on a visual analog scale score of 0-10. The current evidence does not allow us to conclude whether psychological interventions have an effect on self-reported pain scores in women with CPP.
Resumo:
Purpose - We performed a study of laser panretinal photocoagulation in 20 patients with proliferative retinopathy. We compared short exposure, high-energy laser settings with conventional settings, using a 532?nm, frequency doubled, Neodymium–Yag laser and assessed the patients in terms of pain experienced and effectiveness of treatment. Methods - Twenty patients having panretinal photocoagulation for the first time underwent random allocation to treatment of the superior and inferior hemi-retina. Treatment A used ‘conventional’ parameters: exposure time 0.1?s, power sufficient to produce a visible grey-white burns, spot size 300?µm. The other hemi- retina was treated with treatment B using exposure 0.02?s, 300?µm and sufficient power to have similar endpoint. All patients were asked to evaluate severity of pain on a visual analogue scale. (0=no pain, 10=most severe pain). All patients were masked as to the type of treatment and the order of carrying out the treatment on each patient was randomised. Patients underwent fundus photography and were followed up for 6–45 months. Results - Seventeen patients had proliferative diabetic retinopathy, two had ischaemic central retinal vein occlusion and one had ocular ischaemic syndrome. The mean response to treatment A was 5.11, compared to 1.40 treatment B, on the visual analogue scale, which was statistically significant (P=0.001). All patients preferred treatment B. Further treatments, if required, were performed with treatment B parameters and long-term follow-up has shown no evidence of undertreatment. Conclusions - Shortening exposure time of retinal laser is significantly less painful but equally effective as conventional parameters.
Resumo:
Background - The objective of this study was to investigate the association between ethnicity and health related quality of life (HRQoL) in patients with type 2 diabetes. Methods - The EuroQol EQ-5D measure was administered to 1,978 patients with type 2 diabetes in the UK Asian Diabetes Study (UKADS): 1,486 of south Asian origin (Indian, Pakistani, Bangladeshi or other south Asian) and 492 of white European origin. Multivariate regression using ordinary least square (OLS), Tobit, fractional logit and Censored Least Absolutes Deviations estimators was used to estimate the impact of ethnicity on both visual analogue scale (VAS) and utility scores for the EuroQol EQ-5D. Results - Mean EQ-5D VAS and utility scores were lower among south Asians with diabetes compared to the white European population; the unadjusted effect on the mean EQ-5D VAS score was −7.82 (Standard error [SE] = 1.06, p < 0.01) and on the EQ-5D utility score was −0.06 (SE = 0.02, p < 0.01) (OLS estimator). After controlling for socio-demographic and clinical confounders, the adjusted effect on the EQ-5D VAS score was −9.35 (SE = 2.46, p < 0.01) and on the EQ-5D utility score was 0.06 (SE = 0.04), although the latter was not statistically significant. Conclusions - There was a large and statistically significant association between south Asian ethnicity and lower EQ-5D VAS scores. In contrast, there was no significant difference in EQ-5D utility scores between the south Asian and white European sub-groups. Further research is needed to explain the differences in effects on subjective EQ-5D VAS scores and population-weighted EQ-5D utility scores in this context.
Resumo:
This thesis explores the interaction between Micros (<10 employees) from non-creative sectors and website designers ("Creatives") that occurred when creating a website of a higher order than a basic template site. The research used Straussian Grounded Theory Method with a longitudinal design, in order to identify what knowledge transferred to the Micros during the collaboration, how it transferred, what factors affected the transfer and outcomes of the transfer including behavioural additionality. To identify whether the research could be extended beyond this, five other design areas were also examined, as well as five Small to Medium Enterprises (SMEs) engaged in website and branding projects. The findings were that, at the start of the design process, many Micros could not articulate their customer knowledge, and had poor marketing and visual language skills, knowledge core to web design, enabling targeted communication to customers through images. Despite these gaps, most Micros still tried to lead the process. To overcome this disjoint, the majority of the designers used a knowledge transfer strategy termed in this thesis as ‘Bi-Modal Knowledge Transfer’, where the Creative was aware of the transfer but the Micro was unaware, both for drawing out customer knowledge from the Micro and for transferring visual language skills to the Micro. Two models were developed to represent this process. Two models were also created to map changes in the knowledge landscapes of customer knowledge and visual language – the Knowledge Placement Model and the Visual Language Scale. The Knowledge Placement model was used to map the placement of customer knowledge within the consciousness, extending the known Automatic-Unconscious -Conscious model, adding two more locations – Peripheral Consciousness and Occasional Consciousness. Peripheral Consciousness is where potential knowledge is held, but not used. Occasional Consciousness is where potential knowledge is held but used only for specific tasks. The Visual Language Scale was created to measure visual language ability from visually responsive, where the participant only responds personally to visual symbols, to visually multi-lingual, where the participant can use visual symbols to communicate with multiple thought-worlds. With successful Bi-Modal Knowledge Transfer, the outcome included not only an effective website but also changes in the knowledge landscape for the Micros and ongoing behavioural changes, especially in marketing. These effects were not seen in the other design projects, and only in two of the SME projects. The key factors for this difference between SMEs and Micros appeared to be an expectation of knowledge by the Creatives and failure by the SMEs to transfer knowledge within the company.
Resumo:
Purpose: Current panretinal laser photocoagulative parameters are based on the Diabetic Retinopathy Study, which used exposures of 0.1 - 0.5 second to achieve moderate intensity retinal burns. Unfortunately, many patients find these settings painful. We wanted to investigate whether reducing exposure time and increasing power to give the same endpoint, is more comfortable and effective. Methods: 20 patients having panretinal photocoagulation for the first time underwent random allocation to two forms of laser treatment: half of the retinal area scheduled for treatment was treated with Green Yag laser with conventional parameters {exposure time 0.1 second (treatment A), power density sufficient to produce a visible grey - white burns}. The other half treated with shorter exposure 0.02 second (treatment B). All patient were asked to evaluate severity of pain on a visual analogue scale ranging from 0 - 10 (0 = no pain, 10 = most severe pain). All patients were masked as to the type of treatment. The order of carrying out the treatment on each patient was randomised. Fundus photographs were taken of each hemifundus to confirm treatment. Results: Of the 20 patients, 17 had proliferative diabetic retinopathy, 2 had ischaemic central retinal vein occlusion and one had ocular ischaemic syndrome. The average pain response to treatment A was 5.11 on a visual analogue scale with a mean power of 0.178 Watt; the average pain response to treatment B was 1.40 with a mean power of 0.489 Watt. Short exposure laser burns were significantly less painful (P < 0.001). Conclusion: Shortening exposure time with increased power is more comfortable for patients undergoing panretinal photocoagulation than conventional parameters.
Resumo:
Background: In December 2007, the National Institute for Health and Clinical Excellence and the National Patient Safety Agency in the UK (NICE-NPSA) published guidance that recommends all adults admitted to hospital receive medication reconciliation, usually by pharmacy staff. A costing and report tool was provided indicating a resource requirement of d12.9 million for England per year. Pediatric patients are excluded from this guidance. Objective: To determine the clinical significance of medication reconciliation in children on admission to hospital. Methods: A prospective observational study included pediatric patients admitted to a neurosurgical ward at Birmingham Childrens Hospital, Birmingham, England, between September 2006 and March 2007. Medication reconciliation was conducted by a pharmacist after the admission of each of 100 consecutive eligible patients aged 4 months to 16 years. The clinical significance of prescribing disparities between pre-admission medications and initial admission medication orders was determined by an expert multidisciplinary panel and quantified using an analog scale. The main outcome measure was the clinical signficance of unintentional variations between hospital admission medication orders and physician-prescribed pre-admission medication for repeat (continuing) medications. Results: Initial admission medication orders for children differed from prescribed pre-admission medication in 39%of cases. Half of all resulting prescribing variations in this setting had the potential to cause moderate or severe discomfort or clinical deterioration. These results mirror findings for adults. Conclusions: The introduction of medication reconciliation in children on admission to hospital has the potential to reduce discomfort or clinical deterioration by reducing unintentional changes to repeat prescribed medication. Consequently, there is no justification for the omission of children from the NICENPSA guidance concerning medication reconciliation in hospitals, and costing tools should include pediatric patients. © 2010 Adis Data Information BV. All rights reserved.
Resumo:
Gamma activity to stationary grating stimuli was studied non-invasively using MEG recordings in humans. Using a spatial filtering technique, we localized gamma activity to primary visual cortex. We tested the hypothesis that spatial frequency properties of visual stimuli may be related to the temporal frequency characteristics of the associated cortical responses. We devised a method to assess temporal frequency differences between stimulus-related responses that typically exhibit complex spectral shapes. We applied this methodology to either single-trial (induced) or time-averaged (evoked) responses in four frequency ranges (0-40, 20-60, 40-80 and 60-100 Hz) and two time windows (either the entire duration of stimulus presentation or the first second following stimulus onset). Our results suggest that stimuli of varying spatial frequency induce responses that exhibit significantly different temporal frequency characteristics. These effects were particularly accentuated for induced responses in the classical gamma frequency band (20-60 Hz) analyzed over the entire duration of stimulus presentation. Strikingly, examining the first second of the responses following stimulus onset resulted in significant loss in stimulus specificity, suggesting that late signal components contain functionally relevant information. These findings advocate a functional role of gamma activity in sensory representation. We suggest that stimulus specific frequency characteristics of MEG signals can be mapped to processes of neuronal synchronization within the framework of coupled dynamical systems.
Resumo:
To make vision possible, the visual nervous system must represent the most informative features in the light pattern captured by the eye. Here we use Gaussian scale-space theory to derive a multiscale model for edge analysis and we test it in perceptual experiments. At all scales there are two stages of spatial filtering. An odd-symmetric, Gaussian first derivative filter provides the input to a Gaussian second derivative filter. Crucially, the output at each stage is half-wave rectified before feeding forward to the next. This creates nonlinear channels selectively responsive to one edge polarity while suppressing spurious or "phantom" edges. The two stages have properties analogous to simple and complex cells in the visual cortex. Edges are found as peaks in a scale-space response map that is the output of the second stage. The position and scale of the peak response identify the location and blur of the edge. The model predicts remarkably accurately our results on human perception of edge location and blur for a wide range of luminance profiles, including the surprising finding that blurred edges look sharper when their length is made shorter. The model enhances our understanding of early vision by integrating computational, physiological, and psychophysical approaches. © ARVO.
Resumo:
A multi-scale model of edge coding based on normalized Gaussian derivative filters successfully predicts perceived scale (blur) for a wide variety of edge profiles [Georgeson, M. A., May, K. A., Freeman, T. C. A., & Hesse, G. S. (in press). From filters to features: Scale-space analysis of edge and blur coding in human vision. Journal of Vision]. Our model spatially differentiates the luminance profile, half-wave rectifies the 1st derivative, and then differentiates twice more, to give the 3rd derivative of all regions with a positive gradient. This process is implemented by a set of Gaussian derivative filters with a range of scales. Peaks in the inverted normalized 3rd derivative across space and scale indicate the positions and scales of the edges. The edge contrast can be estimated from the height of the peak. The model provides a veridical estimate of the scale and contrast of edges that have a Gaussian integral profile. Therefore, since scale and contrast are independent stimulus parameters, the model predicts that the perceived value of either of these parameters should be unaffected by changes in the other. This prediction was found to be incorrect: reducing the contrast of an edge made it look sharper, and increasing its scale led to a decrease in the perceived contrast. Our model can account for these effects when the simple half-wave rectifier after the 1st derivative is replaced by a smoothed threshold function described by two parameters. For each subject, one pair of parameters provided a satisfactory fit to the data from all the experiments presented here and in the accompanying paper [May, K. A. & Georgeson, M. A. (2007). Added luminance ramp alters perceived edge blur and contrast: A critical test for derivative-based models of edge coding. Vision Research, 47, 1721-1731]. Thus, when we allow for the visual system's insensitivity to very shallow luminance gradients, our multi-scale model can be extended to edge coding over a wide range of contrasts and blurs. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
Developmental learning disabilities such as dyslexia and dyscalculia have a high rate of co-occurrence in pediatric populations, suggesting that they share underlying cognitive and neurophysiological mechanisms. Dyslexia and other developmental disorders with a strong heritable component have been associated with reduced sensitivity to coherent motion stimuli, an index of visual temporal processing on a millisecond time-scale. Here we examined whether deficits in sensitivity to visual motion are evident in children who have poor mathematics skills relative to other children of the same age. We obtained psychophysical thresholds for visual coherent motion and a control task from two groups of children who differed in their performance on a test of mathematics achievement. Children with math skills in the lowest 10% in their cohort were less sensitive than age-matched controls to coherent motion, but they had statistically equivalent thresholds to controls on a coherent form control measure. Children with mathematics difficulties therefore tend to present a similar pattern of visual processing deficit to those that have been reported previously in other developmental disorders. We speculate that reduced sensitivity to temporally defined stimuli such as coherent motion represents a common processing deficit apparent across a range of commonly co-occurring developmental disorders.
Resumo:
Adapting to blurred or sharpened images alters perceived blur of a focused image (M. A. Webster, M. A. Georgeson, & S. M. Webster, 2002). We asked whether blur adaptation results in (a) renormalization of perceived focus or (b) a repulsion aftereffect. Images were checkerboards or 2-D Gaussian noise, whose amplitude spectra had (log-log) slopes from -2 (strongly blurred) to 0 (strongly sharpened). Observers adjusted the spectral slope of a comparison image to match different test slopes after adaptation to blurred or sharpened images. Results did not show repulsion effects but were consistent with some renormalization. Test blur levels at and near a blurred or sharpened adaptation level were matched by more focused slopes (closer to 1/f) but with little or no change in appearance after adaptation to focused (1/f) images. A model of contrast adaptation and blur coding by multiple-scale spatial filters predicts these blur aftereffects and those of Webster et al. (2002). A key proposal is that observers are pre-adapted to natural spectra, and blurred or sharpened spectra induce changes in the state of adaptation. The model illustrates how norms might be encoded and recalibrated in the visual system even when they are represented only implicitly by the distribution of responses across multiple channels.
Resumo:
Visual hyperacuities.are a group of thresholds whose values surpass that expected by the anatomical and optical constraints of the eye. There are many variables which affect hyperacuities of which this thesis considers the following .. 1. The effect of contrast on displacement detection and bisection acuity. It is proposed that spatial summation may account for the different response of these two hyperacuities compared with the contrast response of vernier acuity. 2. The effect of references on displacement detection. These were shown to greatly enhance performance when present. Their effect was, however, dependent upon the temporal characteristics of the displacement. 3. The effect of spatial frequency on vernier acuity. Evidence from this experiment suggests that vernier performance can be explained on the basis of the output of orientationally selective spatial frequency filters. 4. Evidence for a weighting function for visual location using random dot clusters. The weighting attached to different parts of the retinal light distribution was found to alter non-linearly with increasing offset from the geometric center of the cluster. A relationship between dot density and peak amplitude of the weighting function was found. 5. Spatial scaling of vernier acuity in the peripheral field. With careful choice of a technique which did not allow separation and eccentricity to co-vary it was found possible to scale vernier acuity both for two lines and two separated dots. 6. The effect of increasing age on hyperacuity. No change in vernier acuity with age was found which contrasted with displacement detection and bisection acuity both of which showed a significant decline with increasing age.
Resumo:
Background - An evaluation of standard automated perimetry (SAP) and short wavelength automated perimetry (SWAP) for the central 10–2 visual field test procedure in patients with age-related macular degeneration (AMD) is presented in order to determine methods of quantifying the central sensitivity loss in patients at various stages of AMD. Methods - 10–2 SAP and SWAP Humphrey visual fields and stereoscopic fundus photographs were collected in 27 eyes of 27 patients with AMD and 22 eyes of 22 normal subjects. Results - Mean Deviation and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post hoc analysis revealed overlap of functional values among stages. In SWAP, indices of focal loss were more sensitive to detecting differences in AMD from normal. SWAP defects were greater in depth and area than those in SAP. Central sensitivity (within 1°) changed by -3.9 and -4.9 dB per stage in SAP and SWAP, respectively. Based on defect maps, an AMD Severity Index was derived. Conclusions - Global indices of focal loss were more sensitive to detecting early stage AMD from normal. The SWAP sensitivity decline with advancing stage of AMD was greater than in SAP. A new AMD Severity Index quantifies visual field defects on a continuous scale. Although not all patients are suitable for SWAP examinations, it is of value as a tool in research studies of visual loss in AMD.
Resumo:
Presentation Purpose:To determine methods of quantifying the sensitivity loss in the central 10o visual field in a cross section of patients at various stages of age-related macular degeneration (AMD). Methods:Standard and short-wavelength automated perimetry (SAP and SWAP) visual fields were collected using program 10-2 of the Humphrey Field Analyzer, in 44 eyes of 27 patients with AMD and 41 eyes of 22 normal subjects. Stereoscopic fundus photographs were graded by two independent observers and the stage of disease determined. Global indices were compared for their ability to delineate the normal visual field from early stages of AMD and to differentiate between stages. Results:Mean Deviation (MD) and Pattern Standard Deviation (PSD) varied significantly with stage of disease in SAP (both p<0.001) and SWAP (both p<0.001), but post-hoc analysis revealed overlap of functional values between stages. Global indices of focal loss, PSD and local spatial variability (LSV) were the most sensitive to detecting differences between normal subjects and early stage AMD patients, in SAP and SWAP, respectively. Overall, defects were confined to the central 5°. SWAP defects were consistently greater in depth and area than those in SAP. The most vulnerable region of the 10° field to sensitivity loss with increasing stage of AMD was the central 1°, in which the sensitivity decline was -4.8dB per stage in SAP and -4.9dB per stage in SWAP. Based on the pattern deviation defect maps, a severity index of AMD visual field loss was derived. Threshold variability was considerably increased in late stage AMD eyes. Conclusions:Global indices of focal loss were more sensitive to the detection of early stage AMD from normal. The sensitivity decline with advancing stage of AMD was greater in SWAP compared to SAP, however the trend was not strong across all stages of disease. The less commonly used index LSV represents relatively statistically unmanipulated summary measure of focal loss. A new severity index is described which is sensitive to visual field change in AMD, measures visual field defects on a continuous scale and may serve as a useful measure of functional change in AMD in longitudinal studies. Keywords: visual fields • age-related macular degeneration • perimetry
Resumo:
Over the full visual field, contrast sensitivity is fairly well described by a linear decline in log sensitivity as a function of eccentricity (expressed in grating cycles). However, many psychophysical studies of spatial visual function concentrate on the central ±4.5 deg (or so) of the visual field. As the details of the variation in sensitivity have not been well documented in this region we did so for small patches of target contrast at several spatial frequencies (0.7–4 c/deg), meridians (horizontal, vertical, and oblique), orientations (horizontal, vertical, and oblique), and eccentricities (0–18 cycles). To reduce the potential effects of stimulus uncertainty, circular markers surrounded the targets. Our analysis shows that the decline in binocular log sensitivity within the central visual field is bilinear: The initial decline is steep, whereas the later decline is shallow and much closer to the classical results. The bilinear decline was approximately symmetrical in the horizontal meridian and declined most steeply in the superior visual field. Further analyses showed our results to be scale-invariant and that this property could not be predicted from cone densities. We used the results from the cardinal meridians to radially interpolate an attenuation surface with the shape of a witch's hat that provided good predictions for the results from the oblique meridians. The witch's hat provides a convenient starting point from which to build models of contrast sensitivity, including those designed to investigate signal summation and neuronal convergence of the image contrast signal. Finally, we provide Matlab code for constructing the witch's hat.