33 resultados para tilt-table testing
em Publishing Network for Geoscientific
Resumo:
Analyses of spatial structure of hydrophysical fields and its vertical evolution in the Northeast Atlantic in a layer from the surface down to 2-2.5 km are carried out based on results of measurements in a testing area (31°-36°N, 20°-26°W) southeast of the Azores in autumn 1993. A description of an anti-cyclonic lens (ACL) of Mediterranean water (MW), which was found in the eastern part of the testing area from data of sets of sequential surveys, is presented. Analysis of CTD and XBT measurements in an area west of the lens allows to conclude that despite some contraction of width of the Azores Current directed eastward (from 60-80 km to 50-60 km) its total eastward volume transport for a period of time from October to November does not vary much. It is shown that intermediate salinity maxima in the northern part of the testing area formed by advection of MW and meddy destruction weakens while intersecting the Azores frontal zone (AFZ) from north to south, displacing itself to larger depth, and increases in thickness. Analysis of data shows that the number of lenses observed within the selected area north of the AFZ is two times more than that observed south of it. North of the AFZ observed salinity maximum and local temperature maxima may be associated with accumulation of heat and salt because of the fact that the AFZ is not only a southern boundary of penetration of MW into the North Atlantic, but also is a "semitransparent" boundary for Mediterranean lenses.
Resumo:
New heat flow observations have been made in the Iberia abyssal plain off the Galicia margin along the transeat of Ocean Drilling Program Leg 149 drill sites. in order to investigate the nature of this unusually wide and deep continet-ocean transition region. Our results indicate the presence of three separate zones. Average values of 47.5 +/- 3 mW/m in the westernmost zone III agree with predictions of standard oceanic lithospheric models for its estimated age of 126 Ma. In contrast, the heat flow within zone II is 5-15 mW/m higher than predicted. assuming that the mantle heat flow remains constant across the basin. This region of high values is coincident with the location of a major intra-crustal "S"-type reflector east of ODP Site 900. and the anomaly is consistent with the presence of 2-3 km of primarily upper continental crust above the reflector, with concentrations of radiogenic components similar to those from granodiorite samplles dredged off Galicia Bank. It is not, however, consistent with the low values of heat production measured on gabbroic sanhples from its western end at ODP Site 900. In zone I, detailed measurements across the tilted fault block south of ODP Site 901 show consistent variations which closely match predictions due to the effects of basement structure and sediment deposition. There is no evidence for variations due to vertical convective transport along the dipping basement fault block. Once corrected for these variations. measurements in zone I yield average values that agree quite well with previous measurements across Calicia Bank. indicating no systematic landward increase in heat flow with decreasing amounts of continental, extension.