13 resultados para real von Neumann measurement

em Publishing Network for Geoscientific


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three long-term temperature data series measured in Portugal were studied to detect and correct non-climatic homogeneity breaks and are now available for future studies of climate variability. Series of monthly minimum (Tmin) and maximum (Tmax) temperatures measured in the three Portuguese meteorological stations of Lisbon (from 1856 to 2008), Coimbra (from 1865 to 2005) and Porto (from 1888 to 2001) were studied to detect and correct non-climatic homogeneity breaks. These series together with monthly series of average temperature (Taver) and temperature range (DTR) derived from them were tested in order to detect homogeneity breaks, using, firstly, metadata, secondly, a visual analysis and, thirdly, four widely used homogeneity tests: von Neumann ratio test, Buishand test, standard normal homogeneity test and Pettitt test. The homogeneity tests were used in absolute (using temperature series themselves) and relative (using sea-surface temperature anomalies series obtained from HadISST2 close to the Portuguese coast or already corrected temperature series as reference series) modes. We considered the Tmin, Tmax and DTR series as most informative for the detection of homogeneity breaks due to the fact that Tmin and Tmax could respond differently to changes in position of a thermometer or other changes in the instrument's environment; Taver series have been used, mainly, as control. The homogeneity tests show strong inhomogeneity of the original data series, which could have both internal climatic and non-climatic origins. Homogeneity breaks which have been identified by the last three mentioned homogeneity tests were compared with available metadata containing data, such as instrument changes, changes in station location and environment, observing procedures, etc. Significant homogeneity breaks (significance 95% or more) that coincide with known dates of instrumental changes have been corrected using standard procedures. It was also noted that some significant homogeneity breaks, which could not be connected to the known dates of any changes in the park of instruments or stations location and environment, could be caused by large volcanic eruptions. The corrected series were again tested for homogeneity: the corrected series were considered free of non-climatic breaks when the tests of most of monthly series showed no significant (significance 95% or more) homogeneity breaks that coincide with dates of known instrument changes. Corrected series are now available in the frame of ERA-CLIM FP7 project for future studies of climate variability.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One main point of the air electric investigations at the atlantic 1965 and 1969 was the record of the potential gradient in the troposphere with free and captive balloon ascents. The course of the field vs. altitude above the sea differs from that over land. A remarkable enlargement of the field strength occurs at the altitude of the passat inversion. The electric voltage between ionosphere and earth could be obtained by integrating the potential gradient over the altitude. Such computations have been made by balloon ascents simultaneous over the ocean and at Weissenau (South Germany), From 15 simultaneous measurements the average value of the potential of the ionosphere over the ocean is 214 kV and over South Germany 216 kV, that means very close together. Because of the small differences also between the single values it can be concluded that in generally the ionosphere potential has an equal value over these both places at one moment. From the potential of the ionosphere VI, the field strength E0 and the conductivity lamda o, both measured at the sea surface, the columnar resistance R could be derived to 2.4 x 10**17 Ohm x m**2. By correlation of the single values of the ionosphere potential with the potential gradient measured simultaneously at the surface of the sea a linear proportional relationship exists; it follows from this result, that R is nearly constant. The mean value of the air-earth current density over the ocean could be calculated by using the measured values of the small ion density with respect to the electrode effect prooved at the equator station. The current density was only 0.9 x 10**-12 A/m**2, which means, a three and a half times smaller value than estimated by Carnegie and accepted up to now. Therefore it seems to be necessary to correct the former calculations of the global current balance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The uniform triangulation of the whole glacierized area of the Eastern Cordillera of Bolivia provided the first comparable geometrie basis for an accurate photogrammetric height evaluation of glaciers in the mountain range from the far south up to the Peruvian border. A total of 1775 glaciers, larger than 0.1 ha, were recorded in 16 mountain ranges ofthe East- ern Cordillera. Snow lines in the outer tropics can now be analysed with an accuracy of European standards. In spite of the widemeshed network of meteorological stations this allows a more pre- eise climatic differentiation to be made, particularly at high altitude sites. The methods and results of the analysis are described. Because of these results it becomes necessary to revise and refine previous concepts of the spatial distribution of climatic phenomena. Characteristics of glaciers in the Bolivian Cordillera obviously depend on the NE to SW decline in precipitation. The snow lines which are found at an altitude of 4500 m on the north- eastern slope directed towards the Yungas climb up to 5200 m on the lee slope towards the Alti- plano. The N to S increase in snowline elevation is not as significant as expected. With some res- ervation a 100 m fall in the snowline elevation in the Bolivian Cordillera can be explained by an increase in precipitation of about 50 mm.