4 resultados para Spectrum analyzers
em Publishing Network for Geoscientific
Resumo:
One of the goals of EU BASIN is to understand variability in production across the Atlantic and the impact of this variability on higher trophic levels. One aspect of these investigations is to examine the biomes defined by Longhurst (2007). These biomes are largely based on productivity measured with remote sensing. During MSM 26, mesopelagic fish and size-spectrum data were collected to test the biome classifications of the north Atlantic. In most marine systems, the size-spectrum is a decay function with more, smaller organisms and fewer larger organisms. The intercept of the size-spectrum has been linked to overall productivity while the slope represents the "rate of decay" of this productivity (Zhou 2006, doi:10.1093/plankt/fbi119). A Laser In-Situ Scattering Transmissometer was used to collect size-spectrum data and net collections were made to capture mesopelagic fish. The relationship among the mesopelagic fish size and abundance distributions will be compared to the estimates of production from the size-spectrum data to evaluate the biomes of the stations occupied during MSM 26.
Resumo:
An unusual polyketide with a new carbon skeleton, lindgomycin (1), and the recently described ascosetin (2) were extracted from mycelia and culture broth of different Lindgomycetaceae strains, which were isolated from a sponge of the Kiel Fjord in the Baltic Sea (Germany) and from the Antarctic. Their structures were established by spectroscopic means. In the new polyketide, two distinct domains, a bicyclic hydrocarbon and a tetramic acid, are connected by a bridging carbonyl. The tetramic acid substructure of compound 1 was proved to possess a unique 5-benzylpyrrolidine-2,4-dione unit. The combination of 5-benzylpyrrolidine-2,4-dione of compound 1 in its tetramic acid half and 3-methylbut-3-enoic acid pendant in its decalin half allow the assignment of a new carbon skeleton. The new compound 1 and ascosetin showed antibiotic activities with IC50 value of 5.1 (±0.2) µM and 3.2 (±0.4) µM, respectively, against methicillin-resistant Staphylococcus aureus.
Resumo:
A Laser In-Situ Scattering Transmissometer (LISST) was used to collect vertical distribution data of particles from 2.5 to 500 µm in size. The LISST uses a multi-ring detector to measure scattering light of particles from a laser diode. Particles are classified into 32 log-spaced bins and the concentration of each bin is calculated as micro-liters per liter (µl/l). The instrument is rated to a depth of 300 m, and also records temperature and pressure. The sample interval was set to record every second. The LISST was attached to the LOPC frame to conduct casts and allow for particle-size comparisons between the two instruments. The LOPC is rated to a depth of 2000 m, thus a short deployment to a depth of 300 m was first conducted with both instruments. The instruments were then returned to the deck and the LISST removed via a quick release bracket so deep LOPC casts could be continued at a station. Raw LISST size-spectrum data is presented as concentrations for each of the 32 size bins for every second of the cast.