16 resultados para Scandium fluoride

em Publishing Network for Geoscientific


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scandium and lanthanum were analyzed using neutron activation and ICP-MS methods in 60 samples of oceanic phosphorites of various composition and age recovered from continental margins and seamounts in the Atlantic and Pacific Oceans. In the samples studied scandium content ranges from 0.1 to 60 ppm, lanthanum content ranges from 0.4 to 513 ppm, and La/Sc ratio varies from 1.1 to 114. The lowest scandium content occurs in recent phosphorite nodules, intermediate - in Pleistocene phosphatic sand, and the highest - in ancient seamount phosphorites. Process of scandium accumulation in the phosphorites is mainly controlled by their specific surface area and duration of their contact with ocean water. Lanthanum concentrates in the phosphorites much more intensely than scandium. Correlation between scandium and lanthanum distribution is weak, and it appears only when average concentrations of these elements in various groups of samples are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The dataset provides detailed information on the study that was conducted in Lahore's 7 major towns. The sample was taken from 472 tubewells and analyzed for major cations and anions using APHA 2012 techniques as explained herein. Besides, E.coli determination was done to check for microbial contamination. The data includes results from PHREEQC modeling of As(III)/ As(V) species and saturation indices as well as Aquachem's computed hydrochemical water facies. The WHO (2011) and EPA standards included in Aquachem identified the parameters that where in violation. Bicarbonates dominated the groundwater types with 50.21% of the samples exceeding the EPA maximum permissible limit of 250 mg/L in drinking water. Similarly, 30.51% of the samples had TDS values greater than 500 mg/L while 85.38 % of the samples exceed 10 µg/L threshold limit value of arsenic. Also, instances of high magnesium hazard values were observed which requires constant assessment if the groundwater is used for irrigation. Higher than 50% MH values are detrimental to crops which may reduce the expected yields. The membrane filtration technique using m-Endo Agar indicated that 3.59% samples had TNC (too numerous to count) values for E.coli while 5.06% showed values higher than 0 cfu/ 100 ml acceptable value in drinking water. Any traces of E-coli in a groundwater sample indicate recent fecal contamination. Such outcomes signify presence of enteric pathogens. If the groundwater is not properly dosed with disinfectants it may cause harm to human health. It is concluded that more studies are needed and proper groundwater management implement to safeguard the lives of communities that depend solely on groundwater in the city.