130 resultados para Probe diameter
em Publishing Network for Geoscientific
Resumo:
The dataset is based on samples collected in the framework of the project SESAME, in the Ionian, Libyan and Aegean Sea during March- April 2008. The objectives were to measure the standing stocks and calculate the production of the microbial compartment of the food web, describe the vertical distribution pattern and characterize its structure and function through the water column. Heterotrophic bacteria, Synechococcus, Prochlorococcus and Virus abundance: Subsamples for virus, heterotrophic bacteria and cyanobacteria (Synechococcus spp. and Prochlorococcus spp.) counting were analyzed using a FACSCalibur (Becton Dickinson) flow cytometer equipped with a standard laser (488 nm) and filter set and using deionized water as sheath fluid. Fluorescent beads with a diameter of 0.97 µm (Polysciences) were added to each sample as an internal standard, and all parameters were normalized to the beads and expressed as relative units. SYBRGreen I stain (Molecular Probe) was used to stain viral and heterotrophic bacterial DNA. Viruses were counted according to (Brussaard 1984). In order to avoid bulk consentrations of viruses samples we dilluted to Tris-EDTA (pH=8,0) buffer to a final sollution of 1/5 to 1/100. Total abundance and nucleid content classes were calculated using the Paint-A-Gate software (Becton Dickinson).
Resumo:
Underwater spectral reflectance was measured for selected biotic and abiotic coral reef features of Glovers Reef, Belize from March 6 - 10, 2005. Spectral reflectance's of 63 different benthic types were obtained in-situ. An Ocean Optics USB2000 spectrometer was deployed in an custom made underwater housing with a 0.5 m fiber-optic probe mounted next to an artificial light source. Spectral readings were collected with the probe (bear fibre) about 5 cm from the target to ensure that the target would fill the field of view of the fiber optic (FOV diameter ~4.4 cm), as well as to reduce the attenuating effect of the intermediate water (Roelfsema et al., 2006). Spectral readings included for one target included: 1 reading of the covered spectral fibre to correct for instrument noise, 1 reading of spectralon panel mounted on divers wrist to measure incident ambient light, and 8 readings of the target. Spectral reflectance was calculated for each target by first subtracting the instrument noise reading from each other reading. The corrected target readings were then divided by the corrected spectralon reading resulting in spectral reflectance of each target reading. An average target spectral reflectance was calculated by averaging the eight individual spectral reflectance's of the target. If an individual target spectral reflectance was visual considered an outlier, it was not included in the average spectral reflectance calculation. See Roelfsema at al. (2006) for additional info on the methodology of underwater spectra collection.
Resumo:
Measurements of the diameter of O. universa carried out on 30 specimens from 39 samples covering a sediment thickness of 78 m and going back in time to approximately 750 000 y resulted in the construction of a curve of the mean diameter and a curve of the maximum diameter. Both curves, as well as those calculated with the running-averages technique, display cyclic fluctuations with durations of the order of 100 000 y and downwards decreasing amplitudes. These curves are compared with a carbonate curve (on bulk sediment) and an isotopic curve (on benthic foraminifers) obtained from the same set of samples. Correlations are fair to good, but a timelag is noticed between the isotopic curve and the faunal (O. universa mean diameter) curve, with the isotopic signal coming first, in the middle part of the Brunhes Epoch. Biostratigraphic calibration to the paleomagnetic record is provided by four datum planes (two based on calcareous nannofossils, two on diatoms) identified in the succession. Changes recorded in test porosity seem to be less meaningful than changes in test size.