4 resultados para High Beam Quality

em Publishing Network for Geoscientific


Relevância:

80.00% 80.00%

Publicador:

Resumo:

For the production of the orthophoto map Vernagtferner 1979, scale I: 10000, photographs of the flight "Hintereisferner 1979" were used, which have been found to be very suitable for differential rectification. Control points were determined before the flight took place. The processing of nine stereopairs was carried out on an analytical plotter. Simultaneously with the on-line plotting of the contour lines the reference data for the computation of the profiles for the differential rectification were recorded. The orthophoto map was covered by four aerial photographs. A smooth data transfer was ensured because the same computer was used for the data acquisition and the differential rectification. Two printing originals were prepared, one for the outline drawings with contour lines and another for the orthophoto. The print was done in black for the two copies. The data acquisition, the computation of the scanning profiles for the othoprojector and the procedure of the differential rectification are described. The reason for the use of on-line drawn contour lines is explained. Further applications, also for digital contour lines, are introduced. Possibilities for the achievement of high photo quality during the reproduction are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

High-frequency data collected continuously over a multiyear time frame are required for investigating the various agents that drive ecological and hydrodynamic processes in estuaries. Here, we present water quality and current in-situ observations from a fixed monitoring station operating from 2008 to 2014 in the lower Guadiana Estuary, southern Portugal (37°11.30' N, 7°24.67' W). The data were recorded by a multi-parametric probe providing hourly records (temperature, salinity, chlorophyll, dissolved oxygen, turbidity, and pH) at a water depth of ~1 m, and by a bottom-mounted acoustic Doppler current profiler measuring the pressure, near-bottom temperature, and flow velocity through the water column every 15 min. The time-series data, in particular the probe ones, present substantial gaps arising from equipment failure and maintenance, which are ineluctable with this type of observations in harsh environments. However, prolonged (months-long) periods of multi-parametric observations during contrasted external forcing conditions are available. The raw data are reported together with flags indicating the quality status of each record. River discharge data from two hydrographic stations located near the estuary head are also provided to support data analysis and interpretation.