2 resultados para DIODE INTERFEROMETER

em Publishing Network for Geoscientific


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The large discrepancy between field and laboratory measurements of mineral reaction rates is a long-standing problem in earth sciences, often attributed to factors extrinsic to the mineral itself. Nevertheless, differences in reaction rate are also observed within laboratory measurements, raising the possibility of intrinsic variations as well. Critical insight is available from analysis of the relationship between the reaction rate and its distribution over the mineral surface. This analysis recognizes the fundamental variance of the rate. The resulting anisotropic rate distributions are completely obscured by the common practice of surface area normalization. In a simple experiment using a single crystal and its polycrystalline counterpart, we demonstrate the sensitivity of dissolution rate to grain size, results that undermine the use of "classical" rate constants. Comparison of selected published crystal surface step retreat velocities (Jordan and Rammensee, 1998) as well as large single crystal dissolution data (Busenberg and Plummer, 1986) provide further evidence of this fundamental variability. Our key finding highlights the unsubstantiated use of a single-valued "mean" rate or rate constant as a function of environmental conditions. Reactivity predictions and long-term reservoir stability calculations based on laboratory measurements are thus not directly applicable to natural settings without a probabilistic approach. Such a probabilistic approach must incorporate both the variation of surface energy as a general range (intrinsic variation) as well as constraints to this variation owing to the heterogeneity of complex material (e.g., density of domain borders). We suggest the introduction of surface energy spectra (or the resulting rate spectra) containing information about the probability of existing rate ranges and the critical modes of surface energy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Laser In-Situ Scattering Transmissometer (LISST) was used to collect vertical distribution data of particles from 2.5 to 500 µm in size. The LISST uses a multi-ring detector to measure scattering light of particles from a laser diode. Particles are classified into 32 log-spaced bins and the concentration of each bin is calculated as micro-liters per liter (µl/l). The instrument is rated to a depth of 300 m, and also records temperature and pressure. The sample interval was set to record every second. The LISST was attached to the LOPC frame to conduct casts and allow for particle-size comparisons between the two instruments. The LOPC is rated to a depth of 2000 m, thus a short deployment to a depth of 300 m was first conducted with both instruments. The instruments were then returned to the deck and the LISST removed via a quick release bracket so deep LOPC casts could be continued at a station. Raw LISST size-spectrum data is presented as concentrations for each of the 32 size bins for every second of the cast.