13 resultados para Chemistry -- Electronic data processing
em Publishing Network for Geoscientific
Resumo:
Analysis for micro-molar concentrations of nitrate and nitrite, nitrite, phosphate, silicate and ammonia was undertaken on a SEAL Analytical UK Ltd, AA3 segmented flow autoanalyser following methods described by Kirkwood (1996). Samples were drawn from Niskin bottles on the CTD into 15ml polycarbonate centrifuge tubes and kept refrigerated at approximately 4oC until analysis, which generally commenced within 30 minutes. Overall 23 runs with 597 samples were analysed. This is a total of 502 CTD samples, 69 underway samples and 26 from other sources. An artificial seawater matrix (ASW) of 40g/litre sodium chloride was used as the inter-sample wash and standard matrix. The nutrient free status of this solution was checked by running Ocean Scientific International (OSI) low nutrient seawater (LNS) on every run. A single set of mixed standards were made up by diluting 5mM solutions made from weighed dried salts in 1litre of ASW into plastic 250ml volumetric flasks that had been cleaned by washing in MilliQ water (MQ). Data processing was undertaken using SEAL Analytical UK Ltd proprietary software (AACE 6.07) and was performed within a few hours of the run being finished. The sample time was 60 seconds and the wash time was 30 seconds. The lines were washed daily with wash solutions specific for each chemistry, but comprised of MQ, MQ and SDS, MQ and Triton-X, or MQ and Brij-35. Three times during the cruise the phosphate and silicate channels were washed with a weak sodium hypochlorite solution.
Resumo:
In recent years, profiling floats, which form the basis of the successful international Argo observatory, are also being considered as platforms for marine biogeochemical research. This study showcases the utility of floats as a novel tool for combined gas measurements of CO2 partial pressure (pCO2) and O2. These float prototypes were equipped with a small-sized and submersible pCO2 sensor and an optode O2 sensor for highresolution measurements in the surface ocean layer. Four consecutive deployments were carried out during November 2010 and June 2011 near the Cape Verde Ocean Observatory (CVOO) in the eastern tropical North Atlantic. The profiling float performed upcasts every 31 h while measuring pCO2, O2, salinity, temperature, and hydrostatic pressure in the upper 200 m of the water column. To maintain accuracy, regular pCO2 sensor zeroings at depth and surface, as well as optode measurements in air, were performed for each profile. Through the application of data processing procedures (e.g., time-lag correction), accuracies of floatborne pCO2 measurements were greatly improved (10-15 µatm for the water column and 5 µatm for surface measurements). O2 measurements yielded an accuracy of 2 µmol/kg. First results of this pilot study show the possibility of using profiling floats as a platform for detailed and unattended observations of the marine carbon and oxygen cycle dynamics.
Resumo:
The data presented here were collected during the cruise SO248 (Project BacGeoPac) with the RV Sonne from Auckland, New Zealand to Dutch Harbor, Alaska/USA. The cruise lasted from May 1, 2016 to June 3, 2016 and 19 vertical CTD-hauls were conducted. The CTD system used during this cruise was a Sea-Bird Electronics Inc. SBE 911plus probe (SN 09-1266). The CTD was attached to a SBE 32 Carousel Water Sampler (SN 32-1119) containing 24 20-liter Ocean Test Equipment Inc. bottles. The system was equipped with double temperature (SBE 3) and conductivity sensors (SBE 4), a pressure sensor (Digiquartz) an oxygen (Aanderaa Optode 4831F) and, an altimeter (Bentos) and a chlorophyll fluorometer combined with a turbidity sensor (FluoroWetlabECO _AFL FL). The sensors were pre-calibrated by the manufacturers. The data were recorded with the Seasave V 7.23.2 software and processed using the SeaBird SBE Data Processing and the ManageCTD-software. The data were processed in the following way: Data obtained during adaptation of the CTD to ambient water conditions were removed manually. The "wildedit", "loopedit", "despike", "binavg" routines were applied. The data were also visually checked and a double sensor check was conducted. The accuracy of the double sensors derived from 56 data sets were: Temperature T = 0.0007 °C; Conductivity: C = 0,0071 mS/cm; Salinity S = 0.0081 psu. The salinity data (S by unsing pss78) were converted to absolute Salinity (SA) by using the TEOS 10 toolbox. The ship position data were derived from the shipboard GPS-system linked to the CTD data. The time zone is given in UTC. The oxygen CTD data were validated by additional measurements of 98 water samples using the Winkler titration method.